  1. there is really no other option, replace the...

    there is really no other option, replace the compressor
  2. need to change the compressor!

    need to change the compressor!
  3. Replies
    73
    Views
    3,258

    change the filter drier

    change the filter drier
  4. Replies
    14
    Views
    1,145

    I hope you serve. good luck

    I hope you serve. good luck
  5. Replies
    10
    Views
    850

    rgb: to lower the low pressure saturation...

    rgb:
    to lower the low pressure saturation temperature of the evaporator, this alarm is not reset immediately for safety equipment
  6. Thread: question

    by servicetrane
    Replies
    2
    Views
    375

    thanks second opinion

    thanks second opinion
  7. Thread: question

    by servicetrane
    Replies
    2
    Views
    375

    question

    guys:

    which is the pressure drop of R-410A per foot of vertical rise?
  8. Replies
    14
    Views
    1,301

    View Post

    Low Saturated Suction Protection — The control will try to
    prevent shutting a circuit down due to low saturated suction
    conditions by removing stages of capacity. These circuit alert
    conditions...
  9. Replies
    14
    Views
    1,301

    Faulty expansion valve, low refrigerant charge,...

    Faulty expansion valve, low
    refrigerant charge, plugged
    filter drier, faulty suction
    pressure transducer, low
    cooler fluid flow.

    Mode 7 caused the compressor
    to unload 6 consecutive
    times...
  10. Replies
    55
    Views
    3,763

    is verified in the gallonage chart. I asked why...

    is verified in the gallonage chart. I asked why the model of the machine or frame of the condenser and evaporator, each letter of the model indicates a component voltages, accessories etc.
  11. Replies
    55
    Views
    3,763

    I'm still waiting to give us the condenser and...

    I'm still waiting to give us the condenser and evaporator frame to really see the required flow. dp since I find it very small, it seems condensser 1 step.
  12. Replies
    55
    Views
    3,763

    have a complete model of the machines?

    have a complete model of the machines?
  13. Replies
    55
    Views
    3,763

    increases the inlet temperature of condenser...

    increases the inlet temperature of condenser water, check the box divider plate of water, which frame is the condenser and evaporator
  14. Replies
    2
    Views
    600

    software update. which is the version that has...

    software update. which is the version that has the machine, that machine is model?
  15. Replies
    55
    Views
    3,763

    sat. cond. temp = 95.6 cond water leaving =89.4...

    sat. cond. temp = 95.6
    cond water leaving =89.4
    APROACH= 6.2°F (high)

    cond press h2o leaving = 14psig
    cond press h2o entering = 14 psig
    DP= 0PSID(bad gauge)numbers pass condensser,press desing...
  16. Replies
    11
    Views
    841

    which is the current model or brand of your...

    which is the current model or brand of your machine?
  17. Replies
    55
    Views
    3,763

    rmarcelo. could take these readings and post...

    rmarcelo.

    could take these readings and post them?

    condenser
    press refrigerant=
    sat. cond. temp
    cond water leaving
    cond water entering
    cond press h2o leaving
  18. Replies
    11
    Views
    841

    the dual-circuit evaporator?

    the dual-circuit evaporator?
  19. Replies
    23
    Views
    1,359

    is not the same standing in front of the machine...

    is not the same standing in front of the machine works seeing as you put your case or half-doubt, I asked for information and do not put
  20. Replies
    23
    Views
    1,359

    I suggest you give information on how the machine...

    I suggest you give information on how the machine is operating.

    pres, evap, sat evap temp, pres ent and water outlet, etc.
  21. Replies
    23
    Views
    1,359

    mark behne: 1-you can give more information...

    mark behne:
    1-you can give more information (model, series) of the machine?
    2 - the ideal is 10psid DP
    3-the aproach for condensaor is 5 ° f
  22. Replies
    23
    Views
    4,128

    would be a good option to put the log of...

    would be a good option to put the log of operation of the machine to help you, if you suspect you may escape the fluxes
  23. Replies
    15
    Views
    2,206

    this is the service bulletin and RTAC

    this is the service bulletin and RTAC
  24. correct refrigerant charge? that has sc sh? a...

    correct refrigerant charge? that has sc sh? a package broken? more data given
  25. Replies
    53
    Views
    2,898

    dehydrators replace filters? adjusted vet sh?

    dehydrators replace filters? adjusted vet sh?