  1. Replies
    3
    Views
    365

    Have you changed the thermostat

    Have you changed the thermostat
  2. Replies
    40
    Views
    1,921

    Jesus was perfect too (according to who...

    Jesus was perfect too (according to who believes). But he got criticized all the time. So don't ask. Enjoy it if you think it is best for you.
  3. Od temp has nothing to do with your issue....

    Od temp has nothing to do with your issue. Service call
  4. Replies
    15
    Views
    715

    Must use OEM motor. Don't ask me why. Otherwise,...

    Must use OEM motor. Don't ask me why. Otherwise, you will keep replacing it yearly.
  5. That is a 5 tons blower. It is capable of moving...

    That is a 5 tons blower. It is capable of moving more than 2000 cfm. Make sure you ask the contractor to configure it to run less than 1400 cfm in your case (I like 1250 max on your case even though...
  6. By the way, according to Lennox, use approach...

    By the way, according to Lennox, use approach when ambient is warm above 65 degrees; use sub cool during cool weather belie 65 degrees AND also artificially raise the head pressure above 105...
  7. Replies
    20
    Views
    959

    I thought NO DIY site

    I thought NO DIY site
  8. You are correct. Today Lennox systems, you will...

    You are correct. Today Lennox systems, you will see that they don't have much of an subcool. Sometimes, it will surprise you.
    But, think about it a little bit. These system run at lower saturated...
  9. You don't need to have llsv on your setup. In...

    You don't need to have llsv on your setup. In facts, it is not good to gave them since it create more issues than help.

    Run the system at lower cfm than 400 since you bring in OSA.

    Try not yo...
  10. Replies
    9
    Views
    444

    If you open the wall up, have same contractor out...

    If you open the wall up, have same contractor out to fix the kink cause it is not good to have it.
    $$$ is between you and your contractor.
  11. With my experience dealing with these trane...

    With my experience dealing with these trane climatuff, you MUST use trane start components. I don't know why but other start kit won't work well with it.
    2nd run your system in a/c mode normally for...
  12. Replies
    8
    Views
    420

    90% of the time, it is the duct works in the...

    90% of the time, it is the duct works in the attic not properly sealed. Especially, when it is 130 degrees up there. I am sure the installers want to get the heck out of there QUICK.
  13. Replies
    1
    Views
    249

    Small panel next to the LEDs located on the short...

    Small panel next to the LEDs located on the short side where the water manifolds/pipes connections are.
  14. Replies
    43
    Views
    1,183

    And the oil keeps disappear? Or the level is...

    And the oil keeps disappear? Or the level is still 1/2 way like you added and it still tripping?
  15. If it served you well for 20 years, then why...

    If it served you well for 20 years, then why change something different?

    Upgrade to higher SEER if you can afford.
    Stay with the technologies.
    Last, stay with Lennox.
  16. Replies
    9
    Views
    379

    Your problem is at outdoor. Trane normally uses...

    Your problem is at outdoor.
    Trane normally uses x-valve on both inside and outside next to the txv. Hopefully you did not remove the old x-valve when you changed the old txv.

    By the way one-way...
  17. Replies
    10
    Views
    578

    It depends on the leakage rate VS the vacuum pump...

    It depends on the leakage rate VS the vacuum pump CFM rate.

    That's why we MUST turn the pump off when it reaches the (magic number or I call it BS number) and wait for 15 to 20 minutes. If the...
  18. Replies
    12
    Views
    548

    You diagnosed correctly.

    You diagnosed correctly.
  19. Replies
    12
    Views
    560

    I think you meant start winding like those old...

    I think you meant start winding like those old Trane did in the early 80's.
  20. All old version ECM (motor with 16 pins) have a...

    All old version ECM (motor with 16 pins) have a PWM on pin 10 like you said. BUT, today ECM motor no longer use PWM. They are communicating with 1 and 0.

    You may wanna scratch your idea with ECM....
  21. Replies
    7
    Views
    351

    Large is good. Just look out for 2 things: 1-...

    Large is good. Just look out for 2 things:
    1- noise since the hole is larger for the blower noise to travel (especially if you have gas heater in the closet).
    2- if you use 1" filter, the filter...
  22. Replies
    40
    Views
    1,673

    Low DT = make sure heat strips not running

    Low DT = make sure heat strips not running
  23. Replies
    57
    Views
    3,508

    If there is no piston, do you think the OP would...

    If there is no piston, do you think the OP would have such data?

    Think dude!

    That why i said "huh"

    Think man! Think!
  24. Replies
    40
    Views
    1,673

    The OP said "8 DT on indoor coil". If it is lack...

    The OP said "8 DT on indoor coil". If it is lack of air flow, then we should have high DT. Common guys.




    Oh yeah baby! Adding more freon will solve all problems relating to A/C.


    To the...
  25. Replies
    57
    Views
    3,508

    Huh! That is the best...

    Huh!





    That is the best question/advice so far.
Results 1 to 25 of 500