    MPO 147 Lockouts

    Wear04,

    If all of your combustion figures are looking good, the cad cell resistance value is within the limits and teh fuel pump is not drawing excessive vacuum, I would focus on draft as the...
  2. Replies
    9
    Views
    2,485

    RE: MA Homeowner

    I am sorry to hear about your V83 problem. By your description, what your technician is pointing to is the supply pipe connection to the boiler. If you are seeing a "mass" or buildup at that...
  3. Noisy Fan Assembly

    Dougster,

    There really isn't much that can be done to adjust or tweak the fan assembly since it is in an enclosed metal assembly. At this point in time I would ask that you contact me at the...
  4. Induced Draft Fan

    The induced draft fans are only supplied, installed and available to Burnham as complete assemblies from the fan manufacturer. They are covered under the one year parts warranty from original date of...
  5. Dougster

    The Independence PV "Power Vented" boiler has been out for several years and has been a very dependable boiler. Any noise you may be hearing with the induced draft fan assembly could be a number of...
  6. Replies
    8
    Views
    2,776

    SCG Problem

    Assumably you are still running this one with the patch cord to the blower. Has anyone concentrated on the blower relay as the possible cause of this? Changing blowers would have isolated the blower...
  7. Replies
    11
    Views
    2,480

    RE: Burnham MPO Lockouts

    Wear04,

    There could be any number of things causing your loclouts. To be able to pinpoint the problem I need to know a little about your system. Are you getting your oil from the tank by gravity...
  8. Replies
    1
    Views
    466

    RE: Thermostat Problems

    One concern I have regarding this question is the age of the boiler. You have stated that the boiler is 29 years old but Burnham has only been configuring its gas boilers with vent dampers since...
  9. Replies
    9
    Views
    2,485

    You're Welcome

    You are most certainly welcome and thanks again for thinking of Burnham.
  10. Replies
    9
    Views
    2,485

    Wiring L7248C

    Sorry for the delay in responding as I somehow missed this one. The L7248C has no provision for receiving a signal to operate for just the high limit circuit from an external zone. The only way...
  11. Followup

    Beckman,

    As far as I can remember from past e-mails, you provided me with only the Installation Supervisor's name and the homeowners name, addess and phone number. I still don't know what your...
  12. Replies
    13
    Views
    1,245

    And.......

    That's correct Leo and if you want to add a few more they would be Burnham Foundry, Bryan Boiler, Burnham Commercial Steel Boiler, Kewanee (consolidated into Burnham Commercial Steel), Thermal...
  13. Replies
    13
    Views
    1,245

    That's Correct BeenThere

    Crown is a part of the Burnham Holdings family of heating companies and we have made several of their section assemblies for some time now.LowPressureGuy is probably referring to the V7 issues that...
  14. Replies
    13
    Views
    1,245

    RE: MPO Controls

    Sounds to me like we need to do a little sales and marketing work in your area if none of your local contractors know about the MPO boiler! As John has already stated, the MPO can handle return water...
  15. Also

    Regarding the answers that one of our Customer Service agents gave you regarding the piping I would probably have to say that she may have been thinking "Hot Water Boiler" when she gave you that...
  16. Steam Boiler Piping

    I have been following this thread for the past several days and am now seeing it going in the wrong direction. Please contact me regarding this situation and I will see to it that your installer is...
  17. Replies
    39
    Views
    5,580

    Circulator Location

    Burnham does ship most of it's boilers with the pump not mounted. We kept the pump on the V8 due to requests from rather large oil companies that asked that we do so. The other models do not have the...
  18. Replies
    9
    Views
    621

    Nuisance Lockouts

    I will have to agree with the others that if this is happening as frequently as you say that there is something external causing it. As stated, this could be an inability to get the oil to the burner...
  19. Replies
    39
    Views
    5,580

    Pump Placement

    As Noel stated, the reason the pump has been mounted on the return of the V8 has more to do with installer demand than anything else. Burnham shows and states in the Installation manual to utilize...
  20. Replies
    10
    Views
    6,899

    RE: Pilot Problems

    The boiler you have there in Montana is a Series 206 model that was originally configured for LP from the factory. If gas valves and multiple thermocouples have been replaced then I too would suspect...
  21. Replies
    10
    Views
    6,899

    Pilot Outage

    It is not the nut for the pilot gas tubing that should be black, it is the housing that the tubing inverted nut threads into that should be black if it is for LP. Many of our distributors do not...
  22. Replies
    10
    Views
    6,899

    Pilot Outages

    Nuisance pilot outages are sometimes a difficult thing to pinpoint the exact cause of. When a gas boiler is converted to LP the Pilot Assembly must be part of that conversion. A simple way to check...
  23. Replies
    62
    Views
    6,215

    BTUH Outputs

    I'm not entirely sure why you are comparing a 4 section MPO with a V83 or WGO-3. A 3 section MPO or MPO-147 has a greater output than a V-83 or WGO-3. As a comparison the V-83 has a Net IBR Hot Water...
  24. Replies
    29
    Views
    2,947

    Thanks guys

    Thanks Guys,

    I don't ever expect everyone to like me, our company and our products. All I ask is for someone to keep an open mind to the issues that all manufacturers encounter from time to time....
  25. Replies
    29
    Views
    2,947

    RE: Best Boiler

    Well....my last Camry went through a muffler every two years and I ended up with some pretty severe body rot around the rear wheel wells after 3 years. Was it well maintained and serviced.....yes....
Results 1 to 25 of 56
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event