  1. Replies
    31
    Views
    1,438

    My local supplier sells the cps SL3000, saw one...

    My local supplier sells the cps SL3000, saw one on line review and owner liked it a lot.
    Anyone used that model.
  2. Replies
    31
    Views
    1,438

    GOOD FREON SNIFFER

    Hello: Doing a lot of 410a installs over the last few years. Now thinking about some repairs and seeking leaks using my older cps unit. Its listed for 12, 22 and 134a. Don't know how it would work...
  3. Replies
    18
    Views
    814

    Looks like we got off subject a little. Seems my...

    Looks like we got off subject a little. Seems my G twin is best at liquid recovery, so removing the stem & hooking up high side would be beneficial.
  4. Replies
    18
    Views
    814

    Recovery with stem removed?

    Hello: I have a appoin single for a couple of years. Bought a twin recently, but found it not notably faster. Of course they recommend you use a valve core remover tool with side port. Do any of you...
  5. Replies
    3
    Views
    251

    The ductwork is sized more like 3 tons. The...

    The ductwork is sized more like 3 tons. The owners "says its a 3 ton evap. when house was built, and if you can make it 3.5, that would be good". I like to know the size of old equipment when I...
  6. Replies
    3
    Views
    251

    Summit Evaporator question

    Hi: I have a customer with 20 year old evap. that is leaking. Trying to match size. Model number is CAJ53-ME1 ,owner says its a 3 ton. Another contractor installed a 3.5 condenser last year. Like to...
  7. Replies
    18
    Views
    1,055

    I got a set of SMAN3 recently. Used it a couple...

    I got a set of SMAN3 recently. Used it a couple of time, like the large display. Only thing, on a r22 to 410 evap & condenser change, used for micron gauge. Left pump on for a hour and only pulled to...
  8. Replies
    4
    Views
    232

    TRANE gas furnace question

    Hi: I have a customer with a resently install Trane horz, furnace. A 30 year old house with a ICP 2 ton H coil & 3.5 ruud condenser. I want to install a 2.5 or 3 ton evap. can not figure what size...
  9. Replies
    10
    Views
    505

    So I guess a lot of guys use only one set of...

    So I guess a lot of guys use only one set of manifold gauges now days?
  10. Replies
    10
    Views
    505

    One gauge 2 refrigerants

    Hi: I have been interested in the digital manifold gauges with sc & sh displayed. Nice to do a repair and know everything that's going on at one place. But have always used two set of gauges ( 22 &...
  11. Replies
    19
    Views
    629

    Extra liquid line filter

    Came across a goodman condenser with small filter inside after breaking it down for scrape. Have many of same units, mostly 2.5 tons in development. Was wondering upon a evap. or other repair, can...
  12. Replies
    16
    Views
    755

    Put the smaller piston in and it ran like a...

    Put the smaller piston in and it ran like a champ, thanks for all the help.
  13. Replies
    16
    Views
    755

    The space may be to too limited for a trx valve....

    The space may be to too limited for a trx valve. The system is not over charge, with no frigerant add and long line set. The condenser came with two pistons ( .60 & .61) , they are too small to fit...
  14. Replies
    16
    Views
    755

    Yeh: I'm going back Monday. It will still be...

    Yeh: I'm going back Monday. It will still be around 80 degrees outside. Hope the homeowner doesnt says its cool, but never shuts off. If that's the case , I guess my next move would be to put a...
  15. Replies
    16
    Views
    755

    The homeowners were leaving on a trip as I...

    The homeowners were leaving on a trip as I finished. indoor dry blub was about 83 degrees, 64 degrees coming from floor registers.
  16. Replies
    16
    Views
    755

    Strange manifold pressures ?

    Hi: I replace a leaking evap. coil in hud house miller heater. Got a "A" coil almost exact dimensions, except its a 3 ton in place of 2.5 ton evap., fit like a glove. Installed new 2.5 ton 410-A...
  17. Replies
    11
    Views
    502

    Thanks, I'm going to visit RE Michel , I talked...

    Thanks, I'm going to visit RE Michel , I talked to new bee there and he could not help me. I see one in there catalog at my office.
  18. Replies
    11
    Views
    502

    Uncased "A" coil

    Hi: trying to finds a replacement evaporator coil to set in a miller counterflow. Old one has big leak. Most of the places I call here in new jersey have cased coils. I think they still make downflow...
  19. Replies
    2
    Views
    271

    sorry; went bact and found another plate with a...

    sorry; went bact and found another plate with a good model number. Some times things are so close you can't see them.
  20. Replies
    2
    Views
    271

    Heat Controller condenser

    Hi: Trying to size a couple of old heat controller condensers, first is 3237-7-18A & 3228-11-18A . Both are matched up with indoor evaps with no label on old natural draft furnaces. old furnace have...
  21. Replies
    13
    Views
    983

    Hi: the price for MO99 is 60% of cost of R-22 in...

    Hi: the price for MO99 is 60% of cost of R-22 in my area. The cylinder looks like 25#. Started to read a little online , seems you start with 85% of estimated charge. Have to check and see what oil...
  22. Replies
    13
    Views
    983

    MO99 drop in refrigerant?

    Hi: I see this refrigerant at my supplier. They say its popular for R22- units. I have a condenser change out next week and thinking about trying it. I'm buying a dry 3 ton ruud condenser and...
  23. Replies
    10
    Views
    650

    Yeh.. I did a couple water damaged ductwork...

    Yeh.. I did a couple water damaged ductwork reeplacement from evap overflowing. Had water filling up that black plastic wrap under home with gallons & gallons of water. When I open the plastic the...
  24. Replies
    10
    Views
    650

    I've done simular with the loose insulation,...

    I've done simular with the loose insulation, removed the garden hose off evap. drain etc. My other concern is the 5+8" sheetmetal chimney, the crappy gas burner.. etc. I was thinking a ruud...
  25. Replies
    10
    Views
    650

    HUD home furnace replacement

    Hi: I was trying to see about any pros or cons to replacing a miller counter flow furnace with something like a ruud 90+. The houses in this development are basiclly double wide trailers on a...