Search:

Type: Posts; User: coldrig

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    207

    Carel EVD0000200 Replacement

    Anybody have Idea What need to do to replace EVD0000200 with EVD0000E20 for McQuay screw chiller.Thanks.
  2. Replies
    0
    Views
    233

    McQuay Chiller EEV driver

    What is purpose of Battery attached to McQuay Air Cool Chiller Electronic Expansion Valve Driver.Thanks.
  3. Replies
    28
    Views
    7,714

    Where can I buy these parts you mentioned.Thanks.

    Where can I buy these parts you mentioned.Thanks.
  4. Replies
    0
    Views
    231

    McQuay Chiller Ex Valve Driver

    McQuay Screw Chiller Expansion valve Driver EV driver EVD0000200 is faulty If we replace it with EVD0000E20. Is it required some programming or it is just plug and play. Thanks.
  5. Replies
    289
    Views
    56,502

    VLC-651R Question

    By mistake I give opposite 24vac Supply to Microset ll, It shows very high reading then I correct the polarity with refrence to VLC-651r then display gone. I check with other VLC-651r thermostat is...
  6. Replies
    289
    Views
    56,502

    I try to program VLC-853C3 with ver 2.6 but not...

    I try to program VLC-853C3 with ver 2.6 but not succeed I am attaching two Pictures of VLC-853 and VLC-853C3 please can you tell me how I can program VLC-853C3.Thanks.
  7. Replies
    289
    Views
    56,502

    What is name of Password file.Thanks.

    What is name of Password file.Thanks.
  8. Replies
    0
    Views
    260

    Trane Stepper Module

    We have Trane RTAA and RTAD Chillers, Stepper Module X13650808-05 E, I don't find this Model on net.On ebay there are stepper Modules for RTAA and RTAD X13650455 any body has idea if we can replace...
  9. Replies
    2
    Views
    243

    Hi Deadheaddave, Thanks for informations.

    Hi Deadheaddave, Thanks for informations.
  10. Replies
    2
    Views
    243

    Envision 2.6 Question

    I am trying to send DDC file to Device and getting Error '' DDC file version is incompatible with Device. When I check 'Advance' Device Properties and found Firmware Version 1.15 how to change it....
  11. Replies
    7
    Views
    450

    I change to AV-10 and AV-15 now output showing 1...

    I change to AV-10 and AV-15 now output showing 1 so problem not solved.
  12. Replies
    7
    Views
    450

    Thanks for reply. Controller is New I am using as...

    Thanks for reply. Controller is New I am using as a test purpose,anyhow I will use AV 0-49 and inform you.Thanks again.
  13. Replies
    7
    Views
    450

    VisualLogic Question

    Why Transfer Function is changing Value from 21.6 to Zero for AI-2. VLC-853C3 Picture is attached.
  14. Replies
    5
    Views
    1,736

    Hi,I need copy of Alerton '' LTBT-TM-DSPDV'' will...

    Hi,I need copy of Alerton '' LTBT-TM-DSPDV'' will you please send me if you still have.My email is in my profile.Thanks.
  15. Replies
    0
    Views
    354

    Alerton BACtalk Manual

    Anybody have BACtalk '' Display Developer's Guide or where to get it.Thanks.
  16. Thread: Mcquay Expert

    by coldrig
    Replies
    4
    Views
    1,094

    acrefertech. Thanks.

    acrefertech. Thanks.
  17. Replies
    5
    Views
    570

    Why VisualLogic menu is not appearing in visio...

    Why VisualLogic menu is not appearing in visio logic menubar.It is suppose to appear.I tried through Tools-- DDC -- VisualLogic but only visio Logic is opening. Thanks for any help.
  18. Replies
    5
    Views
    570

    Thanks I login and problem solved.

    Thanks I login and problem solved.
  19. Replies
    5
    Views
    570

    Alerton Envision for BACtalk 1.3 Question

    I installed Envision for BACtalk 1.3 and I have Tech key for it why Tools menu is not available it is gray. Thanks for any help.
  20. Hi, Question about VLC VAVi SD,There 1-3 AI...

    Hi, Question about VLC VAVi SD,There 1-3 AI according to its specification sheet these can be used for Thermistor or contact My question is can I use AI for 0-5V or 4-24mA signal to monitor duct...
  21. Hi, Question about VLC VAVi SD,There 1-3 AI...

    Hi, Question about VLC VAVi SD,There 1-3 AI according to its specification sheet these can be used for Thermistor or contact My question is can I use AI for 0-5V or 4-24mA signal to monitor duct...
  22. Replies
    0
    Views
    254

    Alerton VAVi-SD Question

    There are 4 Universal inputs,It is written for thermistors.Are these Input only for Temperature Sensors or any analog sensors can be attached like 0-5 Volts or 4-20mA signal. Thanks.
  23. Replies
    3
    Views
    339

    I have TechView, I just want to know if it is not...

    I have TechView, I just want to know if it is not One time Program Sensor. So it mean if I install used in other Machine it will bind in new Machine just by following Binding instructions.
    No traces...
  24. Replies
    3
    Views
    339

    RTAC TEMPRATURE SENSOR

    Is it possible to reprogram RTAC Temperature Sensor Or to remove from from one machine and to fix in other machine of same model.Thanks.
  25. Replies
    8
    Views
    598

    159 is to Unlock screen.It is working.In this...

    159 is to Unlock screen.It is working.In this screen there is no setting menu.
  26. Replies
    8
    Views
    598

    It is written in Trane Manual ''RLC-SVU05A-E4''...

    It is written in Trane Manual ''RLC-SVU05A-E4'' For setting changes,use the password '314 <ENTER>.
    Chiller Model RTAC350.
  27. Replies
    16
    Views
    3,083

    I want to learn Visual Logic programming for...

    I want to learn Visual Logic programming for Alerton controllers I have access to software and controllers to learn but don't know where to start.I will be thankful for any guide or reference to...
  28. Replies
    8
    Views
    598

    Trane DYNA VIEW Question

    I tried to go Setting screen by entering 314 but
    it is not opening any window and remain in Password screen,when I enter 159 it is opening. How can I open setting screen.Thanks.
  29. Replies
    4
    Views
    372

    Your memory is working excellent,Problem is...

    Your memory is working excellent,Problem is solved.Thanks a lot.
  30. Replies
    4
    Views
    372

    Device Manager then Scan Devices and another...

    Device Manager then Scan Devices and another window where you scan and Save to Table then you can click on any device and it will take you to Add/Edit Device profile,when you open that window Device...
  31. Replies
    4
    Views
    372

    Alerton Envision 2.6 Question

    Is it possible to change Device Instance of VLC853 Which is already used for one network.Or how to use used VLC853 or VLC651R for other site with different Device Instance.Thanks.
  32. Replies
    8
    Views
    727

    I still trying,As I removed input and output...

    I still trying,As I removed input and output connections other than power supply so no chance of coil influence.
  33. Replies
    8
    Views
    727

    I check Input voltage are Ok within range.

    I check Input voltage are Ok within range.
  34. Replies
    8
    Views
    727

    Do you have any idea how to check Mitsubishi IGBT...

    Do you have any idea how to check Mitsubishi IGBT used in these VFDs. PM200DVA120-2 This is IGBT Model.Thanks.
  35. Replies
    8
    Views
    727

    Thanks for your reply. I don't find 100uF 25V...

    Thanks for your reply. I don't find 100uF 25V capacitor I am posting picture if you can guide.Thanks. I tried to post picture but fail.Please can you send your email address,my email is in my profile.
  36. Replies
    8
    Views
    727

    Telemecanique VFD ATV38HD64

    There is 3ph 415v at input but display is not On and VFD is not working, anybody have idea what is possible cause.Thanks.
  37. Replies
    0
    Views
    399

    Mcquay Centrifugal Compressor CE100

    Anybody have Mcquay Centrifugal Compressor CE100 overhauling manual.My email in my profile.Thanks.
  38. Thread: EUROTHERM VFD

    by coldrig
    Replies
    2
    Views
    855

    No I did not, Therefore VFD Replaced.

    No I did not, Therefore VFD Replaced.
  39. Replies
    2
    Views
    1,238

    Schneider Automation Server SXWAUTSVR10001

    Anybody has idea where to buy Schneider Automation Server other than Schneider. Or anybody has idea how much it cost my email address is in my profile.Thanks.
  40. Replies
    2
    Views
    721

    Dear JohnLove2ski. Thank you very much for...

    Dear JohnLove2ski. Thank you very much for detailed reply. Tomorrow I will go on site and will apply your instructions. Thanks.
  41. Replies
    2
    Views
    721

    Alerton Envision 2.6 Question

    We have Envision 2.6 network all controllers are VLC651 can I replace faulty controller with VLC853
    If yes So what steps to be taken.Thanks.
  42. Replies
    2
    Views
    955

    I will try your steps.Thanks.

    I will try your steps.Thanks.
  43. Replies
    2
    Views
    955

    Trane Chiller RTAC 375

    Anybody can explain what is this Error in Binding view.Picture attached.Thanks.
  44. Replies
    0
    Views
    508

    McQuay Chiller PEH 100

    McQuay Chiller 100 not Loading what can be the possible cause.Thanks.
  45. Replies
    12
    Views
    3,974

    Thanks

    I am no more working on that site.Anyhow I am thankful to you.
  46. Replies
    0
    Views
    416

    McQuay PEH100 Chiller

    Which Software is used to Program Microprocessor Control Board 860-654873B. Thanks.
  47. Thread: Mcquay Expert

    by coldrig
    Replies
    4
    Views
    1,094

    Sorry if I did not put my question right.My...

    Sorry if I did not put my question right.My question can we replace faulty board with any old with same model number.I don't know where they use old board so what is procedure to reset and install...
  48. Thread: Mcquay Expert

    by coldrig
    Replies
    4
    Views
    1,094

    Mcquay Expert

    We have Mcquay Centrifugal Chiller PEH100,with Control Board P/N 860-6548738-5c. These borads are obsolete but old boards are available on Ebay. My question is available board p/n is same only last...
  49. Thread: Alerton VLC

    by coldrig
    Replies
    0
    Views
    583

    Alerton VLC

    Anybody have LTBT-TM-GEN4VLC_13 for VLCs Installation and Operation Guide.Thanks.
  50. Replies
    9
    Views
    2,631

    Thanks

    Got it.