    I use a tall dye cartridge with 2 hoses connected...

    I use a tall dye cartridge with 2 hoses connected to it with valves at the end for checking oil level. Gives you a good 6 inches of clear sight.
  2. Replies
    1
    Views
    301

    it is a desiccant style drier... little desiccant...

    it is a desiccant style drier... little desiccant balls inside of it..
  3. Replies
    17
    Views
    2,211

    Not incorrect when you break down the formula......

    Not incorrect when you break down the formula... A "ton" is 12k btu.. so your temp rise in there is going to satisfy the ton part of the equation
  4. Replies
    13
    Views
    1,010

    We have the star certification here in Ohio which...

    We have the star certification here in Ohio which is the nate equivalent ... I held it for 10 years.. it didn't do anything for me.. now instead of an on line recertificationit is a proctored exam in...
  5. Replies
    35
    Views
    2,386

    Distributor is plugged... Have had multiple...

    Distributor is plugged... Have had multiple issues with this.. Poke a hole in the bottom of dist. And drain oil.. If that doesn't cure it, hole at each pass and punch distributors..
  6. Replies
    1
    Views
    305

    Mix valve is also check valve... Replace and u r...

    Mix valve is also check valve... Replace and u r good
  7. Replies
    37
    Views
    2,680

    the one thing missing from all of these posts is...

    the one thing missing from all of these posts is go do the job... in this day and age of phones and what not just go do it, you have the resources to figure it out.. it was broke when you got there...
  8. 134a high condensing temperatures = plugged cap...

    134a high condensing temperatures = plugged cap tube.... either that or low on freon due to leak... need a service guy to discern which..
  9. Replies
    15
    Views
    3,057

    Does the unit have an economizer?? Is the f.a....

    Does the unit have an economizer?? Is the f.a. damper going to the return of the unit?? Motorized v.s. manual keeps the cold or hot out when in off cycle.
  10. Replies
    15
    Views
    3,057

    Free cooling during colder times when there is an...

    Free cooling during colder times when there is an air conditioning load... To meet fresh air requirement in relation to occupancy and indoor air quality.
  11. Replies
    25
    Views
    2,782

    I use a good ol stick rule on belt drive units.....

    I use a good ol stick rule on belt drive units.. I teach the newbies the 4 point rule on straight edges and use dial for the big boys... Everyone is correct when they say it is a dying art. I only do...
  12. Good analogy Val.. The science behind it is...

    Good analogy Val.. The science behind it is Dalton's law... And your p.t. Chart... Raise the pressure you raise the temp and lower the pressure you lower the temp... So if it compression and load...
  13. Replies
    5
    Views
    711

    Depends on which wires are hooked to the 006.....

    Depends on which wires are hooked to the 006.. 1&2 are your sensor input 3 is your mode 45678 etc are system faults.. You will get voltage errors on ltb you can read with meter...
  14. Replies
    7
    Views
    747

    Hard start or torque assist is a small capacitor...

    Hard start or torque assist is a small capacitor used to "kick the compressor" in the butt while starting.. it costs under 20 bucks.... Not the same as a soft start which gradually increases your Hz...
  15. Replies
    7
    Views
    747

    You definately need more help... #1 scrolls are...

    You definately need more help... #1 scrolls are noisy.. more noisy if running backwards. Suspend the horizontal unit and isolate from ceiling. #2 dimming lights. May be phase imbalance in your...
  16. Motor 7.9 amps * s.f. 1.25 equals 9.8 amps....you...

    Motor 7.9 amps * s.f. 1.25 equals 9.8 amps....you are now pulling 8.4 which is still below max amps... Is say let it fly... Worst case scenario you are putting in a 3/4 h.p. motor which you would end...
  17. Thread: MO99 Retro

    by passintyme
    Replies
    10
    Views
    1,480

    Go to Emerson's web site, they have a chart on...

    Go to Emerson's web site, they have a chart on existing refrigerents and retrofit refrigerents including oil and pt charts...
  18. Replies
    2
    Views
    352

    You never have a flat tire ...... Until you do ...

    You never have a flat tire ...... Until you do ...
  19. Replies
    24
    Views
    2,753

    Tif zx1

    Tif zx1
  20. Thread: Manometer

    by passintyme
    Replies
    10
    Views
    1,144

    Fieldpiece makes a digital that is perfect... Use...

    Fieldpiece makes a digital that is perfect... Use for high,low, air,flue,gas..
  21. Thread: Pay

    by passintyme
    Replies
    6
    Views
    1,175

    Union 40 non union 20's

    Union 40 non union 20's
  22. Temp rise does not care what the od temp is......

    Temp rise does not care what the od temp is... You are correct that if 0 then 100 would be correct.. Certain mfgs will have you direct more or less air towards the high limit so as to trick the...
  23. Replies
    11
    Views
    2,047

    On all trane boards with a reliatell board or a...

    On all trane boards with a reliatell board or a ucp board you can hook the outside sensor to terminal #1 & 2... This will run the system at 68 heat and 72 cool.. Or there about depending on...
  24. Replies
    0
    Views
    431

    Mitsubishi splits

    Just a FYI regarding all Mitsubishi split systems... Any and all information can be found at www.mylinkdrive.com happy hunting
  25. Replies
    20
    Views
    3,031

    not to bad

    Cat. 0 requirements are cotton shirt and pants, safety glasses, rubber gloves with leather gloves over them and rated boots. Not a bad gig considering what is at stake. Sounds like you need the full...