  1. Replies
    28
    Views
    2,461

    Pony: I agree good communication isn't the same...

    Pony: I agree good communication isn't the same as being a good tech. Though it's ALWAYS part of being a good businessman, in case you want to go into business yourself. Even when you work with...
  2. Replies
    28
    Views
    2,461

    Hey Pony: I think people want to make sure...

    Hey Pony: I think people want to make sure they're encouraging good tradesmanship. It helps hold high standards and customer respect.

    But as for your question of what the site is good for, you DID...
  3. Replies
    11
    Views
    761

    Also: most contractors don't use polyiso under...

    Also: most contractors don't use polyiso under slabs. Extruded polystyrene is the more accepted practice, IMO. Polyiso, while having nice high r-values (though changeable with time) absorbs lots of...
  4. Replies
    11
    Views
    761

    I'm looking a little closer at the nomograph now....

    I'm looking a little closer at the nomograph now. First, it's mostly linear (I'd forgotten). That makes things pretty easy. The first thing you need to know is your heat flux, hopefully you already...
  5. Replies
    11
    Views
    761

    No I've never seen the formula. It should only...

    No I've never seen the formula. It should only take a few steps to derive it from the graph, you just have to determine formulas for the various curves. How's your diff. eq's?
  6. Replies
    17
    Views
    1,573

    Interesting point. But I believe the...

    Interesting point. But I believe the communication line still functions at or less than 60hz, and the skin effect is a feature of AC and a function of frequency. In which case the skin depth is over...
  7. Replies
    17
    Views
    1,573

    I'm mostly familiar with the Fujitsus, but you'd...

    I'm mostly familiar with the Fujitsus, but you'd just get an error code telling you as much and it wouldn't run, I believe. I could look up the error code. Same thing happens if you miswire the...
  8. Replies
    17
    Views
    1,573

    Haha, I had a picture in my head and I didn't let...

    Haha, I had a picture in my head and I didn't let go. It just sounded so ridiculous. Right, it was frost falling off the coil. That's funny.

    Never mind....
  9. Replies
    17
    Views
    1,555

    Nude sunbathing then.

    Nude sunbathing then.
  10. Replies
    28
    Views
    2,461

    Pony: if you've got your Universal certification,...

    Pony: if you've got your Universal certification, that indicates that you've demonstrated knowledge of basic refrigerant handling and environmental implications. Due to regulations that limit...
  11. Replies
    11
    Views
    761

    I sent you the nomograph. Yes, I often double-up...

    I sent you the nomograph. Yes, I often double-up radiant tubing density near walls, especially with windows and doors. But much more important are slab edge and under insulation details: I put at...
  12. Replies
    10
    Views
    521

    Had it right the first time. I wouldn't include...

    Had it right the first time. I wouldn't include an outdoor-reset mixer on the radiant loop unless (maybe) you're in a really extreme climate. Unnecessary complexity. The biggest value of the outdoor...
  13. Replies
    2
    Views
    699

    Pmeunier has it right. Humidity can be evaluated...

    Pmeunier has it right. Humidity can be evaluated as either absolute or relative, most of the time when we measure it we're measuring it as relative. Since warm air can carry more moisture than cold...
  14. Replies
    6
    Views
    1,741

    You didn't mention how old/long ago the...

    You didn't mention how old/long ago the insulation was installed? The VOC's associated with polyurethane foam drop sharply with time, as I understand the current science to indicate. Consider adding...
  15. Replies
    4
    Views
    982

    Plastic on the ground makes sense. Control...

    Plastic on the ground makes sense. Control exterior water: make sure drainage is all set to get water away from the house. Put dehumidifiers in the space, close the vents, insulate the side walls......
  16. Replies
    17
    Views
    1,555

    Perception might go both ways. That is, if you...

    Perception might go both ways. That is, if you get to sort of know your neighbors, or otherwise are aware that there might be one that is potentially bothered by the smoke, then their understanding...
  17. Replies
    4
    Views
    426

    Valves or pumps?

    If I understand, you are throttling your geo exchange loop down for your multiple geo units. Seems like you're overpumping your geo loop: if you have multi-speed pumps you could back them down,...
  18. Replies
    32
    Views
    1,820

    As per the AOP Rules only Professional Members *...

    As per the AOP Rules only Professional Members * can reply with
    advice to the OP. Anyone may post and ask questions. They may even
    question the * member answer but not give advice or expand on the...
  19. Replies
    32
    Views
    1,820

    oops, sorry I didn't see you'd already posted the...

    oops, sorry I didn't see you'd already posted the solution.
  20. Replies
    11
    Views
    667

    Okay, okay, it's been said but: read the manual....

    Okay, okay, it's been said but: read the manual. On many units there's a separate venting manual. There are LOTS of considerations, besides just length and number of elbows, height off ground,...
  21. Replies
    32
    Views
    1,820

    As per the AOP Rules only Professional Members *...

    As per the AOP Rules only Professional Members * can reply with
    advice to the OP. Anyone may post and ask questions. They may even
    question the * member answer but not give advice or expand on the...
  22. Replies
    17
    Views
    1,573

    The change from 12 to 14g wire was unnecessary....

    The change from 12 to 14g wire was unnecessary. Sorry to say, but you should have known that. Larger wire merely entails less resistance, which can almost never cause a problem...

    I wonder about...
  23. Replies
    33
    Views
    2,769

    I have a Sprinter van, which is a completely...

    I have a Sprinter van, which is a completely different beast than a standard American van (I had a Chevy before, for example): MUCH more standing room, easier to get around in. That said, it's crazy...
  24. Replies
    10
    Views
    521

    I'd probably just mix down the radiant with a...

    I'd probably just mix down the radiant with a thermostatic mixing valve. The zone thermostat will limit overheat. The Taco RMB looks interesting, I used something similar (an Automix) in a wood...
  25. Replies
    11
    Views
    761

    There's a somewhat complicated graph called a...

    There's a somewhat complicated graph called a nomograph that relates the intended room temperature (which relates to the floor temp and the insulation/tightness of the building, the provided water...