    Sounds like time to try the old screwdriver to...

    Sounds like time to try the old screwdriver to the ear and try to pinpoint area
  2. Replies
    43
    Views
    3,664

    I didn't read all the posts, maybe someone...

    I didn't read all the posts, maybe someone already mentioned the time honored coffee can repair.
  3. This is where I am, retired and my wholesale...

    This is where I am, retired and my wholesale company went out. So I buy off the internet, not very often do I need anything though.
  4. Replies
    10
    Views
    553

    I just went on EBay and they have many solenoid...

    I just went on EBay and they have many solenoid valves and coils.
  5. Replies
    10
    Views
    553

    Are you able to send a picture of the entire...

    Are you able to send a picture of the entire control area and the furnace
  6. Replies
    10
    Views
    553

    Are trying to find a replacement? Maybe easier to...

    Are trying to find a replacement? Maybe easier to remove all the controls and either convert to millivolt or 24 volt since you have line voltage for the transformer. I know most will answer sell a...
  7. Replies
    14
    Views
    1,246

    Company policy was to change any copper pilot...

    Company policy was to change any copper pilot tubing we found. Seems all had some degree of sulphate restriction. I have found many copper connectors with the flares gone and choked to the point of...
  8. Replies
    32
    Views
    2,097

    Some jobs are 4 tens and people love it. Actually...

    Some jobs are 4 tens and people love it. Actually they get to work their day off for overtime and still have the weekend free
  9. Replies
    23
    Views
    2,012

    Several years ago our local Johnstone had a...

    Several years ago our local Johnstone had a female working the counter. She was the in house expert on motors.
  10. Replies
    12
    Views
    611

    I drain the water lines and leave stat at 55 in...

    I drain the water lines and leave stat at 55 in Portland Oregon area
  11. Replies
    13
    Views
    762

    Same as keeping jumper in green-yellow and...

    Same as keeping jumper in green-yellow and yellow-white at the same time. Keeps coil pulled in
  12. Replies
    13
    Views
    762

    You may want to take the pilot out of the system...

    You may want to take the pilot out of the system for testing. Unplug the molex plug. Install a jumper in the green and yellow holes. After pilot lights remove jumper and install in the white and...
  13. Replies
    6
    Views
    529

    What appliance are asking about and what is the...

    What appliance are asking about and what is the delivery pressure from the meter? If nat gas probably 7".
  14. Replies
    17
    Views
    1,326

    Testing a millivolts system is a little different...

    Testing a millivolts system is a little different from a 24volt system. You must know the values of various pilot generators, what reads to expect across the different test points. What read would...
  15. Replies
    7
    Views
    719

    I think you are correct. They took over the old...

    I think you are correct. They took over the old General Controls co.
  16. Replies
    8
    Views
    330

    Norton igniter. 3.2-3.6 amps Carborundum 2.5-3.0...

    Norton igniter. 3.2-3.6 amps
    Carborundum 2.5-3.0
    You need to take an amp reading
  17. Replies
    7
    Views
    719

    An open read is pretty much useless unless it is...

    An open read is pretty much useless unless it is low. I've seen thermocouples show an open read of 21-22 or so and show 0-1 under load. Remember the values such as 30mv. 250mv. 750mv are open reads...
  18. Replies
    12
    Views
    1,411

    My SWAG is a dirty pilot or restricted orifice

    My SWAG is a dirty pilot or restricted orifice
  19. Replies
    16
    Views
    1,075

    Millivolt systems can be tricky if you have...

    Millivolt systems can be tricky if you have limited experience with them. First you need to know the types of pilot generators and their ratings. Next where to take reads , what they mean and what...
  20. Replies
    48
    Views
    3,930

    What, thermocoupler ?

    What, thermocoupler ?
  21. Replies
    22
    Views
    1,611

    Four items put DNP products into continuos fan...

    Four items put DNP products into continuos fan and no heat
    1-bad transformer 2-open limit/rollout switch 3-open fuse link 4- bad board
  22. Replies
    2
    Views
    319

    Spark generator for a 3 wire system??

    Spark generator for a 3 wire system??
  23. Thread: 60s what is it?

    by mike3
    Replies
    35
    Views
    2,327

    Magic Chef

    Magic Chef
  24. Replies
    11
    Views
    866

    I had the filters across the back of the truck on...

    I had the filters across the back of the truck on top of old metal file drawers I used for fittings. Seemed to work pretty well, open double back doors and they were right there.
  25. Replies
    22
    Views
    4,495

    Speaking of old Lennox units, who remembers the...

    Speaking of old Lennox units, who remembers the in-wall unit, no blower, millivolt system. Sorry I don't have a model number. If memory serves me it was rated at 50,000.