  1. Replies
    8
    Views
    306

    Thanks. Started new thread in pro's section.

    Thanks. Started new thread in pro's section.
  2. Thread: Motor Amps

    by Russ57
    Replies
    10
    Views
    492

    This could get deep if you really want to...

    This could get deep if you really want to understand ohm's law for AC circuits. Lots of mis-info.

    For the original question best to think in terms of power (W) = volts (E) times current (I). If...
  3. Probably easier to replace contactors than find...

    Probably easier to replace contactors than find out which one is bad. Problem could be electrical or mechanical in nature. I'd start by measuring current draw of each coil and then ohm values of...
  4. This comes down to a few things that are at odds....

    This comes down to a few things that are at odds.

    1) IF it is a CCW it needs to be comfortable enough to actually carry in all situations. That rules out a good many guns. If nothing else that...
  5. Replies
    89
    Views
    2,032

    Would imagine long ago original motor only had...

    Would imagine long ago original motor only had one cap lead and orange wire went to one side of cap. Then someone replaced the motor with one that has two cap leads and didn't know that the orange...
  6. Replies
    8
    Views
    306

    Crab master I was hoping you would jump in. Did...

    Crab master I was hoping you would jump in. Did a search on the forum and you seem most likely to be able to help.

    I only jumped out the digital input for the CT (fan status). I did so because I...
  7. Replies
    8
    Views
    306

    Fan CT isn't the problem. Already put a jumper...

    Fan CT isn't the problem. Already put a jumper wire across that digital input. Vista confirms fan status as "on" now. Seems I am going to have to fool the DP input. Would imagine it is a 0-10VDC...
  8. Replies
    8
    Views
    306

    TAC Vista question

    I have one small part, emergency room, of my hospital on a Vista system. The rest is Inet. I know Inet well but not Vista.

    My problem is they did a construction project and they replaced exhaust...
  9. Replies
    12
    Views
    611

    In general.....depending on if it is AC or DC...

    In general.....depending on if it is AC or DC voltage:

    Set meter to DC volts. Press hertz button until you get % in display. Read your PWM signal. If meter says 25% you would go to 25% stroke...
  10. Replies
    35
    Views
    5,507

    A few "rules" might have to be obeyed. Typically...

    A few "rules" might have to be obeyed. Typically you want your cooling tower water to be a certain amount of degrees over your chill water. That depends on your chiller. Ten degrees is usually a...
  11. Thread: Megger readings

    by Russ57
    Replies
    33
    Views
    3,344

    Rules of thumb can equal bad practice. Many...

    Rules of thumb can equal bad practice. Many would assume a 3 phase, 480 motor operates at 480 volts referenced to ground.....but it doesn't:) Since you have one end of the megger on ground you need...
  12. Thread: Megger readings

    by Russ57
    Replies
    33
    Views
    3,344

    You might find the following link helpful. ...

    You might find the following link helpful.

    http://www.biddlemegger.com/biddle/Lowdown-MC.pdf
  13. Replies
    43
    Views
    3,403

    It does get a little cloudy at times:) There...

    It does get a little cloudy at times:)

    There are certainly positive displacment pumps with pistons. Then you have centrifugal chillers that compress refrigerant with an impeller.
  14. Replies
    21
    Views
    1,931

    Your best bet will probably be a "shotgun"...

    Your best bet will probably be a "shotgun" approach. Call up True (800-424-TRUE) and give them model and serial number. You will want to buy the start capacitor, overload, and start relay. Those...
  15. Most walk in's have a "defrost termination and...

    Most walk in's have a "defrost termination and fan delay switch". This is mounted on the evaporator.

    When you go into defrost mode this switch lets the defrost heaters remain energized until the...
  16. Wait a second.....you mention something that we...

    Wait a second.....you mention something that we assume is a 115 volt home unit and next thing we know you are talking three phase. World of difference between something that is using a start cap and...
  17. Thread: Vacuum question

    by Russ57
    Replies
    7
    Views
    858

    Well....if you are at zero, or below as you have...

    Well....if you are at zero, or below as you have stated, and it stays that way, haven't you proven the valves hold?
  18. Replies
    39
    Views
    4,023

    Funny how you can make a walk-in mantain temp...

    Funny how you can make a walk-in mantain temp with a tsat and still have a lot of things wrong. It is a little harder to do that with just a pressure control.

    Do yourself a favor. Learn how to...
  19. Replies
    21
    Views
    2,575

    Yes, I am debating fighting it. But we have a...

    Yes, I am debating fighting it. But we have a great relationhip with the inspector and I'd like to keep it like that.

    A switch in series with the "4" terminal and the loads is the quick and dirty...
  20. Replies
    21
    Views
    2,575

    I'm going to have to get up there and see what...

    I'm going to have to get up there and see what all I have. It turns out both evaporators are hard wired 208. Best I can remember, when I installed A419's in them, one had to be wired for 208 but...
  21. Replies
    21
    Views
    2,575

    No. The 120 volt one just plugs into a ceiling...

    No. The 120 volt one just plugs into a ceiling mounted receptacle. The 208 volt one is all hardwired.

    Kinda looking to find out if NEMA 4X and/or low voltage is required.
  22. Replies
    21
    Views
    2,575

    Always best to ask

    My fire department inspector says we need a switch inside the walk in freezers to kill the evaporator fans in case someone gets trapped inside.

    These are normal pump down type systems. One...
  23. Replies
    17
    Views
    2,500

    Bigtime, just all depends on conditions...

    Bigtime, just all depends on conditions (temps/humdity/etc). You could get away with stuff in some parts of the country that would never fly in others.

    These days I wouldn't even design with a...
  24. Replies
    17
    Views
    2,500

    You would always want primary flow to be larger...

    You would always want primary flow to be larger than secondary flow. You can violate that for short periods but doing so for any degree of time will cause lots of problems with humidity and such.
  25. Also.....lower voltage cause higher amperage "if"...

    Also.....lower voltage cause higher amperage "if" torque is required. In other words torque is proportional to square of voltage. Motors that are being started at reduced voltage are usually seeing...
  26. Replies
    19
    Views
    3,879

    I would be careful saying a run capacitor's main...

    I would be careful saying a run capacitor's main job is to correct power factor.

    I'd rather say the capacitor shifts the phase of one of the windings so that the voltage across the winding is at...
  27. Replies
    7
    Views
    1,502

    Not only is the voltage rating higher on the FNQ...

    Not only is the voltage rating higher on the FNQ series, the interupting current rating is WAY higher. If you don't know the importance of I.C. rating then best you make sure you always put the...
  28. This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  29. Thread: Pics for zw17

    by Russ57
    Replies
    0
    Views
    628

    Pics for zw17

    Here are the pics for the old tube base Barber Coleman controls. This particular one isn't on-line anymore but I do have some that are.

    As you can see I have quite a mix of different "vintages".
  30. Replies
    31
    Views
    9,029

    There is a reason why there are megger...

    There is a reason why there are megger tests....and then they are hi-pot tests.

    A megger test is supposed to be non-destructive. Every insulation class has a rating. We are supposed to be...
  31. Replies
    14
    Views
    2,827

    For normal electrical stuff there is little...

    For normal electrical stuff there is little reason not to reference control voltages to ground. However there are a lot of valid reasons for floating neutrals and grounds. I work at a hospital and...
  32. Replies
    31
    Views
    9,029

    I love my old hand crank Biddle. If buying new...

    I love my old hand crank Biddle. If buying new today I'd go AEMC.

    Match the megger to the voltage classes you work with. If you work on 4,160 motors you need a 5,000 VDC unit.

    IMHO top uses...
  33. Replies
    20
    Views
    3,397

    Hmm, so now I'm a liar? Let me get through this...

    Hmm, so now I'm a liar? Let me get through this hurricane and I'll see if I can figure out how to post a pic.

    Pray tell, what is better about a 10mm?
  34. Replies
    33
    Views
    5,772

    A combination of PH, conductivity, and nitrate...

    A combination of PH, conductivity, and nitrate levels will give you an idea of how much you are leaking. Leave the regulator on. There is no such thing as too much water but you can certainly have...
  35. Replies
    18
    Views
    2,957

    Yes, I did mean an EPR valve. BTW, thanks for...

    Yes, I did mean an EPR valve. BTW, thanks for the education above. I don't normally work on stuff quite like this.
  36. Replies
    23
    Views
    9,192

    Cv equals GPM times (the square root of specific...

    Cv equals GPM times (the square root of specific gravity of the fluid over the pressure drop across the valve). Perhaps an easier way is to say, "Cv is the number of gallons per minute, at 60...
  37. Replies
    18
    Views
    2,957

    I have to admit to not being sure what I should...

    I have to admit to not being sure what I should do. Too bad work isn't interested in me adding a CPR and check valve.

    I think I'll put it back in service, order a TXV, and install it later on.
  38. Replies
    20
    Views
    3,397

    That ain't nuthin. My liebert has pnuematic...

    That ain't nuthin. My liebert has pnuematic controls. 1978 vintage IIRC. Runs like a top.

    Now if you want a real laugh....I have AHU controls.....old barber-coleman....that run on vacuum...
  39. Replies
    9
    Views
    1,362

    Don't guess. Get the performance chart and see...

    Don't guess. Get the performance chart and see if the compressor is operating correctly. Not enough info is given to say for sure.
  40. Replies
    15
    Views
    2,050

    Hard and fast rules are what gets begineers in...

    Hard and fast rules are what gets begineers in trouble.

    It is easy to say "charge by SC with a TXV and charge by SH with an orifice". However such rules assume the TXV or orifice and working as...
  41. Replies
    33
    Views
    5,772

    What is the suction pressure on your chill water...

    What is the suction pressure on your chill water pump? Does the regulator have a part# on it? Why do you think it is letting too much water in?

    Glad the B&G link helped. Chill water systems...
  42. Replies
    18
    Views
    2,957

    The frig section whichs setpoint just fine. ...

    The frig section whichs setpoint just fine. Maybe I don't really have a problem? If I understand you right I'm basically running a -30 evap with 80 degrees of superheat. TXV body is very cold but...
  43. Replies
    10
    Views
    1,377

    Password??? Another of my pet peeves. Systems...

    Password??? Another of my pet peeves. Systems with factory default passwords that can't be changed that anyone can find out about.

    When the control vendor comes to my site I want him to need me...
  44. Replies
    16
    Views
    2,233

    A CRO is piped on the outlet of the evap and a...

    A CRO is piped on the outlet of the evap and a metering device would be piped on the inlet side of the evap (for quick check if not sure of what you have). In the pic it looks like you have a cap...
  45. Replies
    33
    Views
    5,772

    The separator is piped to the expansion tank. ...

    The separator is piped to the expansion tank. Better I give a link. Didn't want to write an essay. This should work.

    http://completewatersystems.com/wp-content/uploads/2011/12/A-307A.pdf
  46. Replies
    18
    Views
    2,957

    This is why I ask you guys questions. Blows my...

    This is why I ask you guys questions. Blows my mind to see a higher suction pressure with just the freezer running than just the frig running.

    Still have to think the frig TXV is bad. It runs...
  47. Replies
    33
    Views
    5,772

    Okay, one chill water pump only??? If so you...

    Okay, one chill water pump only???

    If so you have variable pumping through the chiller. I would certainly cut off the bypass ports on the 3-way valves at the air handlers. Ideally there should...
  48. Replies
    23
    Views
    9,192

    ONICON is nice but it costs money. The other way...

    ONICON is nice but it costs money. The other way is free. The guy might even learn something to boot:) Easy enough to enter the calculation into the BAS and spit it out on any graphic page you...
  49. Replies
    18
    Views
    2,957

    I need medium temp...for frig section. And yes,...

    I need medium temp...for frig section. And yes, right now.
  50. Replies
    18
    Views
    2,957

    Damn, you are right....that is a low temp valve. ...

    Damn, you are right....that is a low temp valve. Very little room. I guess I can get a bushing in there.

    Any thoughts on what sort of suction pressure I should see when on the refrig solenoid is...