Search:

Type: Posts; User: ECtofix

Page 1 of 17 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    5
    Views
    94

    :whistle: Ya never know what kind of...

    :whistle:

    Ya never know what kind of challenges are truly a challenge in this occupation.

    I hope that I was of some help.
  2. Replies
    5
    Views
    94

    That cooler uses a cam lift hinge that's standard...

    That cooler uses a cam lift hinge that's standard on many reach-ins. The door lifts as it opens and I believe there's a notch in the cam bushing that the door's hinge pin settles into to hold it...
  3. Thread: Overpriced

    by ECtofix
    Replies
    14
    Views
    1,814

    Did you ever think you needed a rake for your PM...

    Did you ever think you needed a rake for your PM on/around equipment you service?
  4. Thread: Supera vs True

    by ECtofix
    Replies
    14
    Views
    241

    I needed a part for a R/I cooler made by a...

    I needed a part for a R/I cooler made by a company like that.

    I called their 800 number provided on a sticker inside the unit. From that, I spoke with somebody on the phone that was located in...
  5. Replies
    4
    Views
    125

    Maybe that 30 amp breaker has given out then. ...

    Maybe that 30 amp breaker has given out then. You're the electrician, so you'll get it.

    You can call Jackson with the model and serial number for any questions about the unit. I DO that quite...
  6. Replies
    4
    Views
    125

    Hey Lytning, I think you misread something. Per...

    Hey Lytning, I think you misread something. Per the manual for a JP-24B, the rinse tank element for the 208v version of that dishwasher can be rated at 6.7KW or 8.2KW. So, with the 6.7KW version...
  7. There you go, SandShark! You got me to looking...

    There you go, SandShark! You got me to looking around under service training for the DFG-100 and its service manual is downloadable without any type of logging in:
    ...
  8. Replies
    20
    Views
    992

    Don't forget the "beer can cold" part. Another...

    ah yes...everyone...do what he says...just do it, no problems
    every system from now on regardless of temp gets charged to 30 suction. My life issues are over[/QUOTE]

    Don't forget the "beer can...
  9. I went through a similar bout awhile back when a...

    I went through a similar bout awhile back when a certain fryer manufacturer put Fenwal modules into their pasta cookers to replace their former Honeywell version.

    Anyway, obviously Blodgett has...
  10. Replies
    6
    Views
    279

    That's funny! No, as a professional DIYer, I...

    That's funny!

    No, as a professional DIYer, I learned some tricks of my trade being on here. :eek2:
    >
    >
    >
    >
    >
    >
    >
  11. Replies
    32
    Views
    2,577

    Is the house on a steep hill and IT'S not...uh......

    Is the house on a steep hill and IT'S not...uh... level? :eek:
  12. Replies
    6
    Views
    279

    When I need a manual, I typically search for the...

    When I need a manual, I typically search for the equipment's make + model number + the file extension that manuals are expected to be formatted for - which is PDF.

    In this case, I typed in...
  13. Replies
    32
    Views
    2,577

    The irony is that the gas company already sees...

    The irony is that the gas company already sees that at least once a month. :Faint:
  14. Replies
    80
    Views
    6,839

    The OP (Alaska whatever) hasn't signed on since...

    The OP (Alaska whatever) hasn't signed on since 31 March.

    I didn't read all posts either, but what I saw never made a mention of testing the TXV. Maybe the power element lost its charge?
    ...
  15. Yes, it is available as a separate part. I once...

    Yes, it is available as a separate part. I once ordered one (which is now on our parts stock shelf) hoping it was the problem that caused an unresponsive touch screen on one of our SCCs. However,...
  16. Okay...I'm not meaning to be insulting, BUT... ...

    Okay...I'm not meaning to be insulting, BUT...

    Since we're going there, just please be aware that I don't know what model fryer you're looking at or how old it is. What's the model & serial...
  17. Could be a faulty alarm (speaker), a loose...

    Could be a faulty alarm (speaker), a loose connection, a faulty interface board or control board.
  18. Replies
    17
    Views
    969

    Yup. Done that and learned from it. ...or...

    Yup. Done that and learned from it.



    ...or not cut out soon enough.

    If only part of the evap coil is cooling due to a clogged cap or a low charge, but the stat's sensor is located further...
  19. Replies
    702
    Views
    17,670

    Mike20 hasn't made any posts in this forum yet,...

    Mike20 hasn't made any posts in this forum yet, therefore he cares less than we do. That veers into the realms of total apathy and sets a new benchmark for not caring.

    I'm impressed...but I don't...
  20. Replies
    702
    Views
    17,670

    I don't care either... The best sideways,...

    I don't care either...

    The best sideways, sunset picture I think Ive ever seen. :cheers:
  21. Replies
    702
    Views
    17,670

    A Viagra and Rogaine regime isn't advisable...

    A Viagra and Rogaine regime isn't advisable either.
  22. Replies
    702
    Views
    17,670

    What a great thread this is to dump our...

    What a great thread this is to dump our brain-droppings in. I feel so much better...
  23. Replies
    702
    Views
    17,670

    I sing karaoke.

    I sing karaoke.
  24. Replies
    702
    Views
    17,670

    I couldn't care less... Cowabunga - I...

    I couldn't care less...



    Cowabunga - I don't care...



    I don't care whether it makes it...
  25. Replies
    702
    Views
    17,670

    Oops! Spilt my beer while catching up with this...

    Oops! Spilt my beer while catching up with this thread.

    How careless I am.

    However, there's more in the fridge - specifically set and calibrated for another 32 1/2 beer to replace it.
    >
    >
    >...
  26. Replies
    45
    Views
    1,825

    HEY! I found a link to some great SOCKS! I'm...

    HEY! I found a link to some great SOCKS!

    I'm not going to post it though. I don't want to stir up any arguments.
  27. Replies
    702
    Views
    17,670

    Finally got around to using them. Still need a...

    Finally got around to using them.

    Still need a breaker bar to assist in busting through those BIG toe nails. Sorta resembles a small explosion...with dust flying everywhere and what not.
  28. Replies
    2
    Views
    1,092

    That looks pretty darned good. The few of...

    That looks pretty darned good.

    The few of those relics that I looked at were each an abomination of wiring, fuses bypassed, etc. Each one seemed to scream at me, saying "Hello there newby! ...
  29. Replies
    702
    Views
    17,670

    Bought me some new toenail clippers.

    Bought me some new toenail clippers.
  30. Replies
    41
    Views
    2,029

    Glad I don't do those anymore. I HATED doing...

    Glad I don't do those anymore. I HATED doing those.

    Never done a world grill, but did countless MWEs. A MWE in good condition and with everything working out without any issues could be done in...
  31. Replies
    702
    Views
    17,670

    I don't care that you don't think we care that...

    I don't care that you don't think we care that you cared to go out to some rural place in BF Paraguay to fix that.
    >
    >
    >
    >
    However, Ill bet that was a damn good beer!
  32. Replies
    34
    Views
    1,904

    The OP's two-and-a-half month old problem is...

    The OP's two-and-a-half month old problem is probably resolved. I think the symptoms in post #13 probably proves that post #2 was the correct answer.
  33. Replies
    702
    Views
    17,670

    Just got home from a few at the V. I held out to...

    Just got home from a few at the V. I held out to use my own bathroom. That went well.

    Went to walk out. Door became knob-less. Came off in my hand. A sudden door knob-ular defficiency. I got...
  34. Replies
    29
    Views
    2,788

    I'm in my fifties. My occasional driver is a...

    I'm in my fifties.

    My occasional driver is a pampered, 2005 Silverado 2500HD w/6L gas engine. VERY low miles since I bought it primarily for pulling a camper. It still looks new. It rides...
  35. Replies
    84
    Views
    3,426

    What would be their reasons to con you? Just...

    What would be their reasons to con you? Just wondering.

    Your question is a valid one, for your sake of wanting to remain abreast of the upcoming changes that will impact your trade and...
  36. Replies
    16
    Views
    1,166

    MCAS Yuma was my first duty station as a young...

    MCAS Yuma was my first duty station as a young Marine. I checked in there on Oct 3, 1979. A balmy 103. During my 3 1/2 years there, I think it got down into the 40s once or twice. Been awhile,...
  37. Replies
    38
    Views
    4,526

    That's Northcutt Inc. out of Wichita KS. They...

    That's Northcutt Inc. out of Wichita KS. They were served a notice from the EPA back in June. A FINDING OF VIOLATION. They'll change their tune pretty soon.
  38. Replies
    28
    Views
    1,876

    Just a brand of this draft inducer...

    Just a brand of this draft inducer...

    http://i824.photobucket.com/albums/zz168/ecdusit/draftinducer.jpg

    Just so happens to be the one I've got. I have a 20' long horizontal run for my...
  39. Replies
    38
    Views
    4,526

    Did they talk about it? Many survivors weren't...

    Did they talk about it? Many survivors weren't willing to.


    In my case, it was my uncle. He was ten years old when that natural gas explosion took his life and so many others.

    My grandmother...
  40. Replies
    11
    Views
    583

    The water in the reservoir initially chills as it...

    The water in the reservoir initially chills as it cascades down the plate during the beginning of the freeze cycle. As the water continuously cycles, the water eventually gets cold enough that it...
  41. Replies
    28
    Views
    1,876

    Mine's a XL80 also. The Tjernlund in-line draft...

    Mine's a XL80 also. The Tjernlund in-line draft inducer has been an issue...several times.

    Hey btglow2894, does your furnace-in-question have one? If so, is it working properly?
  42. Replies
    3
    Views
    328

    Took some prying, but I found a phone number. ...

    Took some prying, but I found a phone number. Avantco Refrigeration is 800-678-5517.
  43. Replies
    3
    Views
    328

    From what I read, all you're doing by your doing...

    From what I read, all you're doing by your doing that is merely locking or unlocking the option for accessing modifications to the parameters.

    Avantco's website gives me a 404 error when...
  44. Replies
    21
    Views
    2,464

    Someone like that can make your company look bad...

    Someone like that can make your company look bad in the eyes of the customers. Of course, if the customer becomes privy of his paltry performance, they may take the option of requesting a different...
  45. Replies
    37
    Views
    8,756

    Hey Ray's, For your privacy, please don't put...

    Hey Ray's,

    For your privacy, please don't put your email address in the open forum. The BOTS will harvest it. The MODs will be deleting that shortly. Log in and put your email address into your...
  46. Replies
    38
    Views
    4,526

    Also keep in mind that the R-22A products are...

    Also keep in mind that the R-22A products are marketed primarily to the consumers since they can buy it without any certification...AND...do their own gas-'n-go so they don't have to call a...
  47. Replies
    38
    Views
    4,526

    Exactly. I’ve expressed that...along with...

    Exactly.

    I’ve expressed that...along with NUMEROUS other such distinctions to the PRO-R-22A posters who attempt to defend its use over at Amazon. Thankfully, its availability there is slowly...
  48. Replies
    38
    Views
    4,526

    Skwsproul already posted this once. Here's the...

    Skwsproul already posted this once. Here's the EPA's stance on all things dubbed R-22A:

    http://www.epa.gov/ozone/snap/r22a.html

    The FBI got involved earlier this year:
    ...
  49. Replies
    70
    Views
    6,629

    Thanks. I think this about as SHAMEFUL of a post...

    Thanks. I think this about as SHAMEFUL of a post as I 've ever seen on the WALL OF SHAME.

    Here's a few scaled down copies of keviekev70's original photos of the condenser he found. Notice the...
  50. Thread: Transformers

    by ECtofix
    Replies
    11
    Views
    771

    The 24v secondary is a power source. It must be...

    The 24v secondary is a power source. It must be thought of as completely separate from the 120v circuit that supplies the primary.

    If one leg of the 24v secondary isn't connected to a ground,...