Search:
Type: Posts; User: skunky
Search: Search took 0.02 seconds.
-
02-12-2008, 07:07 PM
Thread: Condenser motors overheating.
by skunky- Replies
- 15
- Views
- 4,930
Is your head Pressure than it Should be In Hot...
Is your head Pressure than it Should be In Hot Weather?
I am in Texas and If you have a unit on the roof with 105 Degree ambient and 112 Degree heat index Due to Humidity Then It will Run Very Hot... -
02-12-2008, 06:58 PM
Thread: Singer refigeration unit.
by skunky- Replies
- 9
- Views
- 2,311
AN Electric Valve?
DO you mean the Pump Down Solenoid? Also if you Low pressure Cut out is set right it would not run In an 18 inch vacuum
-
01-26-2008, 03:25 PM
Thread: Taylor Soft Serve
by skunky- Replies
- 14
- Views
- 1,331
Oh sorry forgot about the Product flowing into...
Oh sorry forgot about the Product flowing into condenser make sure the drip tray is installed it is a long black tray that slides into a slot in the side that catches any overflow from the back...
-
01-26-2008, 03:19 PM
Thread: Taylor Soft Serve
by skunky- Replies
- 14
- Views
- 1,331
Each Night at the Machine Should be broke Down...
Each Night at the Machine Should be broke Down and sanitized with Taylor Sanitizer or you can use bleach and water they recommend Of course you use the powder Sanitzer that you mix with water ...
-
12-31-2007, 04:36 PM
Thread: True parts? Can I substitute ?
by skunky- Replies
- 10
- Views
- 1,028
mallory timers
There is a universal timer made by supco that has and adjustment on the defrost times that i use in every 115v application I run across that has the mallory type timers
-
414
I have not had any problem with 414 On some of the older systems you cant clear the sight glass I just charge the system by amp draw on the Compressor but make sure the box is warm when you start and...
-
12-31-2007, 04:21 PM
Thread: coil temps
by skunky- Replies
- 6
- Views
- 784
do you mean saturation temp or Delta T across...
do you mean saturation temp or Delta T across coils?
-
12-31-2007, 04:17 PM
Thread: Taylor bearing Problem?
by skunky- Replies
- 2
- Views
- 528
taylor
are you having the same problems with both cylinders?
-
12-31-2007, 04:16 PM
Thread: Snyder General Walk-in Cooler
by skunky- Replies
- 18
- Views
- 1,940
If you are just needing the door gasket then just...
If you are just needing the door gasket then just get a sample from one corner measure the gasket and you can order from RHS catalogue
-
12-31-2007, 04:14 PM
Thread: Snyder General Walk-in Cooler
by skunky- Replies
- 18
- Views
- 1,940
door parts
check the brand of doors you have the most likely are made by anthony
but should have model tag up on door frame either in front of back behind the frame that you can see from inside the cooler -
12-31-2007, 04:12 PM
Thread: Snyder General Walk-in Cooler
by skunky- Replies
- 18
- Views
- 1,940
Snyder general
Snyder General products were manufactured By a ICP or Indoor Comfort products Same Company that made Arco aire and Temp star Equipment find A local dealer for Arco aire and they may be able to help...
-
12-31-2007, 04:08 PM
Thread: Line Tap For Large Diameter Pipe
by skunky- Replies
- 9
- Views
- 1,455
Line tap
If you are wanting to pierce the line to recover the refrigerant they make a tool that is a pair of vise grips with a piercing port on it that will pierce the line when you squeeze them on the line...
-
12-29-2007, 07:14 PM
- Replies
- 59
- Views
- 6,503
That is a common situation people who know...
That is a common situation people who know Nothing about Air Conditioning or refrigeration always think it is low refrigerant charge then are shocked when you tell them it is something else
-
12-29-2007, 07:06 PM
Thread: manitowoc 452 self contained
by skunky- Replies
- 48
- Views
- 2,942
If water was running when machine was not running...
If water was running when machine was not running then Float valve is stuck open but that would have been evident when you first looked at the machine
-
04-24-2005, 08:05 PM
- Replies
- 7
- Views
- 1,405
i hate 409a never use it any more I have found...
i hate 409a never use it any more I have found that hot shot 414b works much better plus youdont have to mess with the polyester oil with the hotshot
-
04-24-2005, 08:03 PM
Thread: adjusting hot gas pres.with amperage.
by skunky- Replies
- 21
- Views
- 1,949
get the box as hot as you can run thru derost and...
get the box as hot as you can run thru derost and open doors then set the cpr valve by amp draw and set it within ten % of run load amps and it should be fine
-
04-24-2005, 07:58 PM
Thread: Need serious help
by skunky- Replies
- 23
- Views
- 1,824
If you are trying to cool your pc they have water...
If you are trying to cool your pc they have water coolers that work great out on the market now check into that it has a closed loop water circuit with a tower that has radiator type of coil with a...
-
04-24-2005, 07:47 PM
Thread: convert hoshizaki cube to flake?
by skunky- Replies
- 10
- Views
- 982
cheaper to buy a flaker and install than do that...
cheaper to buy a flaker and install than do that voght ice machines make ice grinder that the cubes fall into after harvesting but i dont think hoshi has anything like that
-
I have seen that in a lot of ice machines but not...
I have seen that in a lot of ice machines but not that new of a machine it should be under warranty and i would just replace the evaporator sometimes if someone used non nickel safe ice cleaner in...
-
04-24-2005, 07:19 PM
Thread: I think they are trying to KILL us early!
by skunky- Replies
- 103
- Views
- 11,133
We dont do any maintenances after 5 pm due to the...
We dont do any maintenances after 5 pm due to the overtime rates the customer is not going to pay overtime for it and we dont pay any of our techs overtime unless it is a paying overtime call unless...
-
04-24-2005, 07:15 PM
Thread: I think they are trying to KILL us early!
by skunky- Replies
- 103
- Views
- 11,133
Yep been there and done that are the maintenances...
Yep been there and done that are the maintenances they are giving you mostly residential? If so it sounds like you work for a telemarketing company if that is the case get out fast!!! there are way...
Results 1 to 21 of 21