08-04-2011, 11:26 AM
Thread: NAE BAcnetIP
by JNorton- Replies
- 4
- Views
- 430
No, you just have to setup the bacnet IP in the...
No, you just have to setup the bacnet IP in the jace and make sure it is enabled off of the correct Ethernet adapter. Should work once everything is enabled in the jace.
-
08-04-2011, 11:25 AM
Thread: Cooling Compressor Pressure Sensors
by JNorton- Replies
- 3
- Views
- 798
Cooling Compressor Pressure Sensors
I have an odd problem any thoughts would be appreciated.
I have a set of screw compressors that have suction and discharge ports on the lines with a PV09AV Veris (0-10V) pressure sensor.
The... -
08-04-2011, 11:11 AM
Thread: NAE BAcnetIP
by JNorton- Replies
- 4
- Views
- 430
NAE is backnet IP compliant. Just do a discovery...
NAE is backnet IP compliant. Just do a discovery with backnet IP on the Jace.
-
06-10-2011, 08:06 AM
Thread: Trane ReliaTel BACnet Controller
by JNorton- Replies
- 7
- Views
- 1,191
I did set the binary output 1 to BAS control. ...
I did set the binary output 1 to BAS control. Also set the out of service points for the unoccupied setpoints to false. I don't have any trouble writing to the temperature setpoint and the occupied...
-
06-09-2011, 06:39 PM
Thread: Trane ReliaTel BACnet Controller
by JNorton- Replies
- 7
- Views
- 1,191
No the unit maintains the arbitrary unoccupied...
No the unit maintains the arbitrary unoccupied setpoints, which don't reflect any available setting.
-
06-09-2011, 01:00 PM
Thread: Trane ReliaTel BACnet Controller
by JNorton- Replies
- 7
- Views
- 1,191
Trane ReliaTel BACnet Controller
I'm setting up a few RTU's with the ReliaTel controllers on board. I was testing the Unoccupied mode and can't seem to get the controller to reflect the unoccupied setpoints when the unit is in...
-
02-26-2011, 06:48 PM
Thread: Protocessor BacNet Comm With Jace
by JNorton- Replies
- 6
- Views
- 653
What are the identifying features of the BTL...
What are the identifying features of the BTL listed protocessor board? If it is dip switches then we don't have that. We are currently using the legacy board.
-
02-25-2011, 07:34 PM
Thread: Protocessor BacNet Comm With Jace
by JNorton- Replies
- 6
- Views
- 653
Thanks for the thoughts, I will be using the...
Thanks for the thoughts, I will be using the contact info on Monday.
I don't necessarily think it is the Jace but I don't have much control over the protocessor board. I know how to pull the... -
02-24-2011, 06:23 PM
Thread: Protocessor BacNet Comm With Jace
by JNorton- Replies
- 6
- Views
- 653
Protocessor BacNet Comm With Jace
I'm having an issue with a AAM branded Jace communicating with a protocessor board in a boiler.
The boiler that contains the protocessor board has a switch on the front that shuts down all...