Search:

Type: Posts; User: ptbrunet

Search: Search took 0.00 seconds.

  1. Replies
    27
    Views
    8,015

    I'd be interested in reactions to this article:...

    I'd be interested in reactions to this article:
    http://allergyclean.com/news/rciproducesozone.htm

    I see there is a non-ozone version of RCI. Are there any studies showing negative aspects of...
  2. Thread: UV Lights

    by ptbrunet
    Replies
    66
    Views
    41,226

    Still battling DSS. I Just read this article...

    Still battling DSS. I Just read this article.

    Since this was written 3 years ago I'm interested in current use and possible success with Bronz-Glow or AST Electrofin.

    Thanks, Pete

    p.s. and...
  3. Thread: UV Lights

    by ptbrunet
    Replies
    66
    Views
    41,226

    Eliminator RPT HO

    My 1.5 year old HVAC system started exhibiting a very bad DSS (Dirty Socks Syndrome) smell when I turned it on during the Christmas break. I would like to buy the most economical and cost effective...
  4. Replies
    29
    Views
    3,535

    From Mayguy: 2nd stage should kick in any time...

    From Mayguy:

    2nd stage should kick in any time you bump up the temp a couple of degrees.

    Is the set up menu set right?

    #170 to 8

    They wire up W2 at both t-stat and furnace?
  5. Replies
    29
    Views
    3,535

    Tech support from Honeywell told me that the...

    Tech support from Honeywell told me that the RTH7400 will make a stage 2 call if the temp is bumped up 5 or 6 degrees. So I bumped it up 10 degrees (not 1 degree at a time as I did to test the stage...
  6. Replies
    29
    Views
    3,535

    How do I tell if my TStat (Honeywell RTH7400) is...

    How do I tell if my TStat (Honeywell RTH7400) is making a stage two heat request? I was able to tell if it was making a stage two AC request by bumping down the set point one degree each time the...
  7. Replies
    29
    Views
    3,535

    The condenser fan does change speeds on an ASX16...

    The condenser fan does change speeds on an ASX16 but it's a very subtle change.
  8. Replies
    29
    Views
    3,535

    Looks like it's working now after a rewire. ...

    Looks like it's working now after a rewire. Amana has purple for the low stage and yellow for the high stage and that threw the installer off. Now getting 4 amps on low and 6 amps on high. I am...
  9. Replies
    29
    Views
    3,535

    >Also, one of the units (the other one) gets into...

    >Also, one of the units (the other one) gets into a state where the fan stays on a low speed for a very long period of time but the compressor doesn't kick in.

    I determined today that what's...
  10. Replies
    29
    Views
    3,535

    Response from Honeywell: The thermostat has...

    Response from Honeywell:


    The thermostat has an internal algorithm that determines the use of second stage of heating and cooling. The algorithm evaluates how far the room temperature is away...
  11. Replies
    29
    Views
    3,535

    >787*50% for 30 seconds Actually, The...

    >787*50% for 30 seconds

    Actually, The AMV80905CXB's lowest speed is 563.
  12. Replies
    29
    Views
    3,535

    I also have a question about how a 2 stage TStat...

    I also have a question about how a 2 stage TStat works. In particular, I'm interested in information on how a Honeywell RTH7400 works with respect to it's stage 1/2 heat/cool algorithms. Is there a...