  1. you should check air flow,make sure its not...

    you should check air flow,make sure its not shutting off on high limit.Also make sure that prving switch is not loosing its draft ,may have clogged tube on the inducer.
  2. Replies
    0
    Views
    398

    HONEYWELL L7224U aquastat

    has any one run into this problem that the c1 has a delay to shut off when the zone closes.
    It seem to run for a second after the zone closes.
  3. Replies
    0
    Views
    418

    L7224U honeywell aquastat

    Hello to everyone.
    Has any one noticed that the circulator side of aquastat has a delay when the zone valves shut off.
  4. Replies
    50
    Views
    4,890

    I see everybogys point with the switches. You...

    I see everybogys point with the switches. You can't foresee a block of ice if the unit has a problem due to system malfuntion or a era on a homeowner who doesnt do annual maintainance.
  5. Replies
    23
    Views
    4,436

    Not to sound stupid but from what i read he has a...

    Not to sound stupid but from what i read he has a new 410a system and a new air handler,Shouldnt that be a txv not a fixed orifice.
    and did he change the filter drier as well
  6. Thread: Lennox A/C

    by kw10925
    Replies
    9
    Views
    1,508

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  7. Replies
    50
    Views
    4,890

    I want to say thank you to all other techs for...

    I want to say thank you to all other techs for your input.I am sorry didnt get back sooner had family issues.I see that two is not a waste. two wet swiches are inportant so you dont have a mess on...
  8. Replies
    50
    Views
    4,890

    Double float switches

    Hello guys.
    Just would like to know your thoughts on haveing two float switches in your drain pan.
    My boss wants two on every install.Is it over kill or is he right.I am new with the company and to...
  9. Replies
    8
    Views
    1,319

    Sorry about the capitalzations. I performed an...

    Sorry about the capitalzations. I performed an ATU on the system.The nozzle
    size was incorrect,went to my spec book and found correct size.All the numbers were good in the 400s for stack . Dont...
  10. Replies
    8
    Views
    1,319

    it is stainless to top threw chimney. has a...

    it is stainless to top threw chimney. has a beckett burner on it. has a stainless cap also.i think because low nozzle size may be the cause.thanks writing me back.
  11. Replies
    8
    Views
    1,319

    chimney staining

    today i went to do an atu on a ect 05 boiler . checked nozzle size was small
    put in correct size . customer said that he had staining coming down his
    white chimney onto his slate roof . was it...
  12. Replies
    20
    Views
    3,004

    How do you check indoor coil to see if it is...

    How do you check indoor coil to see if it is dirty.
    I looked at the top looked clean. Filters were clean also.
    I did clean OD unit. Its rheem/ruud.
  13. Replies
    20
    Views
    3,004

    I am a newbee trying to do it right so forgive...

    I am a newbee trying to do it right so forgive me.
    The indoorcoil was not frozen only suctionline has lot of frost
    at outdoor at the time and onsideof compressor. Could it be
    that the day was not...
  14. Replies
    20
    Views
    3,004

    Suction line frost

    I was working on rheem/ruud 048-10 seer
    indoor coil looked clean and spotless.Cleaned outdoor unit.
    When doing my checks it would have frost up to the compressor.
    I had 55 psi on lowside/175 on...
  15. Replies
    3
    Views
    477

    heatmanager or outdoor reset

    Hello everyone
    Wanna know which is better the beckett heat manager
    or the taco zone panel with outdoor reset
    I am a tech that want to use one of these and then when a
    customer asks me how to...
  16. Thread: trane troubles

    by kw10925
    Replies
    58
    Views
    4,066

    I told him but still sends me on my own I ask to...

    I told him but still sends me on my own
    I ask to go with someone but doestnt
    says i should know it after going to different class
    this not the say as ojt
  17. Thread: trane troubles

    by kw10925
    Replies
    58
    Views
    4,066

    trane troubles

    :confused:
    I am learning the trade, and my boss is giving me jobs.
    Is trane XL1200 superheat or subcooling.
    I am trying my best,I want todo it correctly not half ass.
    How do you know if you have...
  18. Replies
    4
    Views
    819

    space-gaurd 2200

    have a space-gaurd 2200 media filter
    want to know which lennox merv box filter i can use
  19. Replies
    21
    Views
    1,205

    Cracked heat exchanger

    What other way is there to check for bad exchanger
    besides a visual inspection.
  20. The Way It Sounds It May Be The Motor Is It A...

    The Way It Sounds It May Be The Motor
    Is It A Old Style Motor. If It Is The Bearings Are
    Making The Ra Ra Ra Noise. Change Motor And Change
    Burner Coupling. Also Clear Oil Line Filter And...
  21. Replies
    7
    Views
    1,016

    ihave rig vent and soffit vents, never had this...

    ihave rig vent and soffit vents, never had this problem
    this is the first time it happened
  22. Replies
    7
    Views
    1,016

    thanks i appreciate the advive never had this...

    thanks i appreciate the advive
    never had this before i am stumped
    may need to cover all vent and give it a shot
  23. Replies
    7
    Views
    1,016

    Yes mrlight i have a seperate boiler and air...

    Yes mrlight i have a seperate boiler and air handler
  24. Replies
    7
    Views
    1,016

    condication buildup in airhandler

    I am woundering why that i am getting water build up in
    my supply duct . It is not running it is winter and most of my vents are
    covered. Never had this before,the pan has good amount of water
    in...
  25. Replies
    32
    Views
    4,216

    thanks guys for the info this will help alot. i...

    thanks guys for the info
    this will help alot. i am glad this site is here.
  26. Replies
    32
    Views
    4,216

    well gotta go got beeped to go on a no hw call

    well gotta go got beeped to go on a no hw call
  27. Replies
    32
    Views
    4,216

    thanks went to nefi in mass, boces, and other...

    thanks went to nefi in mass, boces, and other classes.
    i keep on learning.
  28. Replies
    32
    Views
    4,216

    I bin in the oil side for 7 yrs only couple...

    I bin in the oil side for 7 yrs
    only couple yrs for ac. thats on and off due to my main field
  29. Replies
    32
    Views
    4,216

    this was a new install Ijust want to do it right...

    this was a new install
    Ijust want to do it right
    not some fly by night tech
    when i am learning i want to learn correctly
    I just get little confused
    iam an oil tech. now i'm doing a/c work
    thank...
  30. Replies
    32
    Views
    4,216

    super heat\sub cooling

    I am just starting in ac work
    i get lost with the superheat and subcooling
    if the super heat is higher than what it is calling for
    you must add right anf if lower than what you need you
    must...