    Electric Heater... SCR, SSR, TRIAC

    On the following design would a SCR, SSR or TRIAC be required?

    http://img688.imageshack.us/img688/4663/neptronic2.jpg

    When do we need them?

    Are they usually in the heater, in the termostat...
  2. Replies
    15
    Views
    2,666

    What is this "pulse thing" in comparison to...

    What is this "pulse thing" in comparison to 0-10vdc, 2-10vdc, 4-20mA?
  3. Replies
    15
    Views
    2,666

    http://img194.imageshack.us/img194/8539/neptronic....

    http://img194.imageshack.us/img194/8539/neptronic.jpg
  4. Replies
    15
    Views
    2,666

    Thanks guys with the illustration (figure 3.18...

    Thanks guys with the illustration (figure 3.18 page 8) of this electric duct heater and all your input I finally understood.
    ...
  5. Replies
    15
    Views
    2,666

    I'm confused... Are they 24 VAC or normaly...

    I'm confused...

    Are they 24 VAC or normaly open dry contact? Or are these the same?

    Is the 24v coming from the heater controler?
  6. Replies
    15
    Views
    2,666

    Again that sheet specifies that... Digital...

    Again that sheet specifies that...

    Digital Inputs: Relay dry contact
    Economizer Output: 0 to 10 VDC
    But it doesn't specify what Y1, Y2, W1, W2 are

    Newbie here... if you know what it is please...
  7. Replies
    15
    Views
    2,666

    I have the spec sheet and installation...

    I have the spec sheet and installation instructions too

    but can't see where they specify what type of control links the thermostat to the heater controler.

    Maybe it says and I just can't...
  8. Replies
    15
    Views
    2,666

    Thermostat "Energizes on call" Y1 and W1

    Working with the Johnson T600 series thermostat

    And Y1, Y2, W1 and W2 are "Energizes on call"

    Is this a 0-10VDC signal or a 24v output... is it pulse or on/off.
  9. Also NFPA 96 indicates that fire dampers are not...

    Also NFPA 96 indicates that fire dampers are not to be installed on exaust ducts of cooking hoods. Would this also apply to the residential?
  10. I found that NFPA 90A doesn't apply to the...

    I found that NFPA 90A doesn't apply to the venting of clothes dryers. Would this imply that fire dampers are never used on cloths dryer ducts?
  11. Dryer and Stove hood dire damper ?????

    http://img24.imageshack.us/img24/7241/woodframe.jpg

    Building: 3 story / 15 unit condo

    If I have a fire rated ceiling and my duct riser (3.25x10) crosses that barrier to go outside do I need to...
  12. Pressure loss through a dryer vent hood

    Hi again guys
    I'm trying to figure out the pressure loss through a dryer vent hood. Can't quite find anything in the ASHRAE loss coefficient tables. But I have an old version.

    ...
  13. Replies
    1
    Views
    509

    Help with fan, pressure, flow, rpm

    I have a system with 3 filter section (pre filter, medium and HEPA)

    I took these measurements with the HEPA filters out (therefore less pressure drop in the system):

    5700 CFM, 5.3" H2O and 2100...
  14. Replies
    11
    Views
    2,135

    I know about the rule, what I really want to know...

    I know about the rule, what I really want to know is specifically where it comes from.
  15. Replies
    19
    Views
    1,088

    More specific questions: I presume for a two...

    More specific questions:
    I presume for a two stage single compressor system... the size of the evaporator and condenser remain the same.
    Does the Evaporator coil (ADP) remain at the same...
  16. Replies
    19
    Views
    1,088

    Pro membership where? Thanks for the link...

    Pro membership where?

    Thanks for the link Powell I will check that out!
  17. Replies
    19
    Views
    1,088

    Some A/C applications seem to have a two stage...

    Some A/C applications seem to have a two stage compressor.

    Low stage (used in normal conditions 80% of the time) and high stage (used during high demands 20% of the time).
  18. Replies
    19
    Views
    1,088

    Refrigeration help required

    Looking for a good book to understand some refrigeration concepts.

    Want to understand concepts like 2 stage compressors vs 2 compressors vs 2 circuits cooling system.

    Do they come with...
  19. Replies
    11
    Views
    2,135

    My Outside Air is at 90F, 50% HR and 38.4...

    My Outside Air is at 90F, 50% HR and 38.4 BTU/lb
    My Inside Return Air is at 70F, 50% HR and 25.4 BTU/lb
    My Air Mixture is around 76F, 53% HR and 29.1 BTU/lb

    The Air Mixture will exit the...
  20. Replies
    6
    Views
    604

    Nice software but what I want really is a rooftop...

    Nice software but what I want really is a rooftop or split system selection software nothing more. To analyze the psychrometric side of things, not really to calculate charges.
    Want to observe the...
  21. Replies
    6
    Views
    604

    It's only for learning purposes. I'm new to the...

    It's only for learning purposes. I'm new to the industry and I work in an office where I can't test any equipment to see how it reacts to changing entering conditions or set point.
  22. Replies
    6
    Views
    604

    Can I find one online? Any company at all,...

    Can I find one online? Any company at all, doesn't matter?

    Anyone has the Lennox product selection software?
  23. Obviously I was referring to the air leaving the...

    Obviously I was referring to the air leaving the cooling coils before any type of reheat.

    From a calculation point of view, do we consider that it's almost always at 90% RH.

    For instance is the...
  24. Air leaving cooling equipment always 90% ???

    Is the air leaving cooling equipment always considered to be at 90% RH?
  25. Replies
    6
    Views
    604

    Need a software AC UNIT SELECTION

    Looking for a selection software (air cooling unit any brand) that would provide me with different pyschrometric specs.
    Where I can punch in a required room conditions or entering air conditions and...
Results 1 to 25 of 50
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event