Search:

Type: Posts; User: bradysmill

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    7
    Views
    580

    Thanks for all, I originally thought that the old...

    Thanks for all, I originally thought that the old controllers were built on Api technology and had to be reconfigured so the Fx would see it, but I uderstand now that Api and Lns is a database on the...
  2. Replies
    7
    Views
    580

    All good sugestions....I heard that keeping the...

    All good sugestions....I heard that keeping the API and LNS together was hard to do, so what I am hearing all of you say is this;
    Pull the Suc 200 (I think thats what it is on the front end) then...
  3. Replies
    2
    Views
    481

    Try a ROOTS meter. Check out the web link, I am...

    Try a ROOTS meter. Check out the web link, I am sure you will find what you are looking for. I have used these for many years.
    ...
  4. Replies
    7
    Views
    580

    Api & Lns Together On Same Lon Network

    I came across an interesting application today and wanted to put it out here for discussion.
    I have a CIRCON building with 30 water source heatpumps that have the UHC-203 series F controllers that...
  5. Replies
    18
    Views
    2,744

    jgrahm, there is no address in your profile.

    jgrahm, there is no address in your profile.
  6. Replies
    9
    Views
    1,151

    Did you check voltages going to pump and is it...

    Did you check voltages going to pump and is it physically running?

    (Just so you know ahead of time..) If you replace the bench pump you should also calibrate the system....expensive to buy the...
  7. Replies
    9
    Views
    1,151

    some of these have two filters in series with...

    some of these have two filters in series with each other...are you sure you checked all of the tubing for obstructions....the pumps do go bad sometims but...

    You can get the lit from the nearest...
  8. Here is the link........... ...

    Here is the link...........

    http://www.microsoft.com/windows/products/winfamily/virtualpc/default.mspx
  9. Replies
    18
    Views
    2,744

    I have station level username and password to do...

    I have station level username and password to do most programming while on the pc, but cannot open the admin tools to change users and all that admin tool can do.
    I'm sorry, Host level is the UN and...
  10. Replies
    9
    Views
    1,151

    This "bench flow loss" is most always going to be...

    This "bench flow loss" is most always going to be nothing more than a clogged filter...there should be a "white" filter on the end of the small hose coming from the "bench pump" I used to keep quite...
  11. Replies
    3
    Views
    500

    Wow, I remember them when they 1st came out....I...

    Wow, I remember them when they 1st came out....I think they were grey...then they upgraded to the blue ones and by that the old apogee was upgraded. If I remember right, I thought they were...
  12. Replies
    9
    Views
    712

    Have you verified your Delta P with a manometer...

    Have you verified your Delta P with a manometer and then checked the cfm on the sticker located on the side of the unit? Could be that you really are low on flow or have a sensor pickup tube that is...
  13. Replies
    18
    Views
    2,744

    Tried it and others....hyperterminal can get the...

    Tried it and others....hyperterminal can get the password? I'm all ears, would be surprised to see that work....any details?
  14. Replies
    18
    Views
    2,744

    Hey guys, I am going back in the morning and I...

    Hey guys, I am going back in the morning and I will try the user name and passwords that Bobby sugested.....I will let you guys know.
  15. Replies
    18
    Views
    2,744

    Talon Staefa admin username and password?

    Anyone know a backdoor username and password for a Staefa workstation using Talon? with R2 programming?
    We need full access to network. Long story....
  16. Replies
    9
    Views
    2,400

    Cant get to the "HI=170" sign in.....I'm now...

    Cant get to the "HI=170" sign in.....I'm now thinking it MUST have to do with the Vonage line (VOIP) I am dialing in on.

    I did not question that at first because I can connect with JCI stuff by...
  17. Replies
    9
    Views
    2,400

    Robertshaw had the account and lost it....PC is...

    Robertshaw had the account and lost it....PC is on site and have no problem with the Operator Interface....There is an existing modem on site and is hooked to Port 1 of the main controller board (not...
  18. Replies
    20
    Views
    2,689

    POWERHEAD has it right....I have a building that...

    POWERHEAD has it right....I have a building that is a state DEP lab, with 110 fume hoods and all are phoenix controlled...Nothing but the best for DEP. Cogeneration plant, heat recovery units and...
  19. Replies
    9
    Views
    2,400

    DMS 3500 HyperTerminal

    What am I doing wrong.....Have a Siebe DMS 3500 with a modem on the job....am dialing in from home....tried diff bauds and stuff, with auto detect and get through the handshake but "auto detect"...
  20. Replies
    19
    Views
    1,747

    CITRIC ACID

    CITRIC ACID
  21. Replies
    19
    Views
    1,747

    It is a slower process but that is what you...

    It is a slower process but that is what you want---You never want to clean any tubes with a fast process.
    Time to do the job varies on the condition of the equipment, size of the system...
  22. Replies
    0
    Views
    632

    Staefa Talon username and password

    Anyone know a backdoor username and password for a Staefa workstation using Talon? We need full access to network. Long story....
  23. Thread: York YPAL

    by bradysmill
    Replies
    6
    Views
    2,836

    Did see a wiring revision pasted over the...

    Did see a wiring revision pasted over the original, will look into this...
  24. Thread: York YPAL

    by bradysmill
    Replies
    6
    Views
    2,836

    That would be great....would be an interesting...

    That would be great....would be an interesting class.
    I think you are right----Copelands are the way to go for sure, is York shipping Copelands as a replacement or just get the Copeland rack from a...
  25. Replies
    8
    Views
    1,553

    Got my spring yesterday. Had them ship a piston...

    Got my spring yesterday. Had them ship a piston too....Baltimore gave me a lead time of 2-3 weeks for the NEW style disch head gasket (there is an old and a new style)
    Chicago offered to send me...
Results 1 to 25 of 191
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event