Type: Posts; User: l123

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    10
    Views
    3,918

    Red Link Gateway and the...

    Red Link Gateway and the www.mytotalconnectcomfort.com are totally uselss if you put the thermostat in Vacation mode. You are locked out of adjusting remotly anything on the thermostat in vacation...
  2. Goodmanhorizontl air haldler - one piece vs. three pieces

    Please tell me which one is better, easier, less install problems
    Goodan 4T units for horizontal low attic (acces is easy via large stair opening):
    (1) AVPTC48
    (2) NBVC2000 + CHPF4260 + TXV (field...
  3. The End

    So the whole duct-work installed by the incompetent Arizonan hvac dealer was removed. It was replaced by newly designed by a degreed engineer duct and was executed in metal, flexes were limited to to...
  4. Replies
    1
    Views
    606

    Carrier Infinity -newest software version?

    What is the newest Infinity Thermostat software version?
    What is the newest Infinity 50XT software version?
    Should Carrier rep have available a computer diagnostic hardware or his only tool is...
  5. In the classes you took did they specify under...

    In the classes you took did they specify under what conditions (I guess static pressure as measured by the system itself) the system shuts itself off? I guess it is acting when it gets a certain...
  6. The uninsulated elbow is attached directly to the...

    The uninsulated elbow is attached directly to the outside metal so it conducts - the area about hand width on either side of that is nice and cold under Arizona sun.

    As to this thing not going...
  7. Just for kicks - this after they said they...

    Just for kicks - this after they said they cleaned the house 3 times. This is old insulation from the attic blown out of the existing ducts that has been cleaned before they started.:D
  8. I still need to answer some of yhour other...

    I still need to answer some of yhour other questions:

    The elbow is about 46" x 16" , metal divided in the center into equal halfs. It appears that on the inside it has a 1/4" black fiber (fiber...
  9. Carrier Infinity- at what static pressure it shuts down?

    Carrier Infinity 15 Packaged - does it shut down when the message to clean or change airfilter or consider duct change?
    Is there certain static pressure at which the unit stops working for a number...
  10. Is the Satisfaction Guarantee or money back from...

    Is the Satisfaction Guarantee or money back from Carrier?

    The static pressures are from the Infinity - see teh pictures on the other post.
    But they did meassure the pressure in each side of teh...
  11. Please take a look at the pictures in my today's...

    Please take a look at the pictures in my today's post. The elbow has less than 2.5 inch straight run before it turns, it blows into 22x22x36 plenum. But the openings in the machine are h16xw14 and...
  12. Maybe because it was just switched from the COLD...

    Maybe because it was just switched from the COLD cycle test?
  13. Install in Arizona accordingly to Arizona Standard

    A lot of photographs: http://picasaweb.google.com/ArizonaInstall

    All welcome to review, comment, site authorities violated, etc.
    The install started May 18 and we are not done yet on May 30....
  14. Does this mean that the elbow cannot be beginning...

    Does this mean that the elbow cannot be beginning at the machine? This would mean that 99% residential installs in Arizona are improper - which I am sure by now they are anyway.
  15. Elbow size matters on packaged Infinity15 5T unit?

    The saga continues. What should be the size/dimension of the 90 deg elbow connecting the Infinit15 5T packaged unit through the roof. The machine is 2000 cfm, and has factory supply & return openings...
  16. Interesting non-fix and results

    The installer put his Magnehelic to the elbow on the roof and got 0.5 on supply and 0.1 on return. He said supply is the problem I said return is the problem. At the very same time the Infinity...
  17. If you show us will fix - that is their approach...

    If you show us will fix - that is their approach to advertised 36 point QC. As to the static ressure - the answer was we might be able to get it to 1.0 but cannot guarantee that and will never get to...
  18. Small correction - the 100 outside temp was from...

    Small correction - the 100 outside temp was from the sensor mbakong in the sung on the black painted iron. The actual temps did not get above 95 in my location.
  19. Actually I used your suggestion and selected...

    Actually I used your suggestion and selected someone who was branded as one of the best in the area. I am sorry I did not go with the second choice which was selected using my reasonablness criteria.
  20. Urgent help - Carrier Infinity 15 Packaged new install problem

    Yesterday, I got the new install of a 5T Infinity heat pump (replaced nearly 5T Goetl) by Carrier Authorized dealer in Arizona. The "Exterior Static Pressure" is about 1.25" at 1750 cfm and goes up...
  21. Replies
    9
    Views
    501

    I am sure he did not ask for my 30 years. But he...

    I am sure he did not ask for my 30 years. But he did ask for the corrective reaction . My mood does not matter it is responders' comment attitude that requires correction. Your comment is jusr as...
  22. Replies
    9
    Views
    501

    I know who I am looking for, and the operative...

    I know who I am looking for, and the operative word is: reasonable - as in reasonable quality of work for a reasonable price and ability to reasonably follow manufacturer's installation manual and...
  23. Replies
    9
    Views
    501

    Carrier contractor needed in Phoenix area.

    Carrier contractor needed in Phoenix area.
    Need a reasonable contractor to replace a 5T packaged unit with Carrier packaged or split.
    Could you recomend someone please?
  24. Replies
    16
    Views
    2,059

    Double check the size of ground loop. The rule of...

    Double check the size of ground loop. The rule of thumb is 300 ft/1T.
    This would mean 4x300=1200 ft for your ground loop.
    Because there is not much spacing within each 150' bore, that bore is not...
  25. Replies
    0
    Views
    1,263

    Any ground source hp installer in phoenix area

    I am searching for a reasonable residential ground source hp installer in Phoenix AZ area? Anyone out there?