  1. Replies
    25
    Views
    1,797

    These arent perfect answers but thoughts to think...

    These arent perfect answers but thoughts to think of. Good questions.

    Remember higher temps = higher pressures. whatever the metering device. A slightly low system wont show the same pressures as...
  2. Replies
    8
    Views
    4,011

    The beer in the walk-in needs to be colder 34-36...

    The beer in the walk-in needs to be colder 34-36 degrees preferably.
    The glycol loop needs to be somewhere under 30 but this only removes heat buildup from the tap lines. Most run around 25 deg...
  3. Replies
    14
    Views
    3,705

    Appreciate all your inputs. Living and...

    Appreciate all your inputs.

    Living and learning still.
  4. Replies
    14
    Views
    3,705

    Chuck the oil is saturated with it. Cracker I...

    Chuck the oil is saturated with it.

    Cracker I saw that copeland bulletin in your link, thanks.

    Instead of saying the only solution I should have said is system replacement the best solution....
  5. Replies
    14
    Views
    3,705

    R134a and green slime anyone?

    Green slime in refrigerant. Heard of it never seen it but then I have only been in the biz for a few decades.

    Maybe someone can help identify this.

    I have a small R134a system, 8' cold well...
  6. Replies
    1
    Views
    588

    Alternate refrigerant recovery.

    Good sense and logic says recover all refrigerants. I allways attempt to recover as complete as possible.
    An unintentional accidental release recently of R404a caused me to try and understand just...
  7. Replies
    84
    Views
    5,173

    I recently looked at published internet equipment...

    I recently looked at published internet equipment pricing. Shipping costs are extra.

    When compared to our sell prices we are very close pricewise on every item they list with our ship and handling...
  8. Replies
    11
    Views
    2,120

    yep If I remember right that was a particularly...

    yep
    If I remember right that was a particularly nasty store. Is that the one with a million pigeons on the roof. They had moved into and shat over all the equipment. Equip was pretty old and heat...
  9. Replies
    11
    Views
    2,120

    In the late 90s I was with a company where we did...

    In the late 90s I was with a company where we did the service and maintenance on around 240 KM stores in the southwest.
    We had one guy who did all the PM inspections in all of AZ. 6 or7 guys in AZ...
  10. Replies
    2
    Views
    729

    Thankyou Powell Yeah I knew it was a 98 model...

    Thankyou Powell

    Yeah I knew it was a 98 model changeout. guess I should have know the A too but didnt register.
  11. Replies
    2
    Views
    729

    Oil questions conversion 404a

    Copeland mn#LACA-0131A-TAC-800 sn#CT98102235

    Putting a closed up bakery on line after a 4 year shutdown. System is at least 30 years old no condenser tag.

    W/IN freezer system flat leaks found...
  12. Replies
    23
    Views
    1,165

    :) I know this thread is going astray but I think...

    :) I know this thread is going astray but I think all you answered the OPs question very well.

    I wasnt talking about a 40 ton just a 2 ton my newest guy was working on today. His logic was that...
  13. Replies
    23
    Views
    1,165

    "It isn't the amount of time, it's how clean he...

    "It isn't the amount of time, it's how clean he gets the system when doing it. It can take a lot longer to clean a large system than a small system"

    Sorry I just went through this with a tech...
  14. 50k BTU/h Too much air flow, motor set on high...

    50k BTU/h
    Too much air flow, motor set on high speed, duct too large, low gas pressure, fan delay, all these need to be checked by your service company.
    Check the temperature rise across the...
  15. Replies
    12
    Views
    942

    Check with wright/hennepin electric (whe.org) I...

    Check with wright/hennepin electric (whe.org)
    I have several customers who are monitored by them. they can do temperature, water, fire, burglar whatever. and they serve a wide area around the TCs...
  16. Thread: Hallowell HPs

    by airon
    Replies
    8
    Views
    884

    oops double post. How do I just delete these?

    oops double post.

    How do I just delete these?
  17. Thread: Hallowell HPs

    by airon
    Replies
    8
    Views
    884

    Thanks coldin utah I'll see if I cant figure out...

    Thanks coldin utah I'll see if I cant figure out that E.
    50% is a nice savings.
  18. Replies
    16
    Views
    1,460

    ERV/HRV simply exchange the air in the home. HRV...

    ERV/HRV simply exchange the air in the home. HRV for the north country. They do not for the most part provide enough makeup air for a wood burner and exhaust.
    That said many folks do use them...
  19. Replies
    23
    Views
    5,438

    Whats your water temp? Outside temp? If the...

    Whats your water temp? Outside temp?
    If the system was sized correctly I wouldnt think there would be any need for electric backup at all.
    If your water (loop) temp is say 55deg then I would think...
  20. Replies
    18
    Views
    2,465

    You will not go wrong spending the extra 14 seer...

    You will not go wrong spending the extra 14 seer dollars for a 95% high efficiency variable speed 2 stage Goodman furnace. Those extra dollars will earn their way.
    ...
  21. Thread: boiler room

    by airon
    Replies
    8
    Views
    757

    Thats called a destabilizer. One who causes you...

    Thats called a destabilizer. One who causes you to slip and break the purple peeper out.
    Closely related to the gremlins that snicker from behind the pipes at 3AM wich cause unknown flame failures.
  22. Replies
    11
    Views
    513

    Vision pro 3h 2c w outside senser is all we use...

    Vision pro 3h 2c w outside senser is all we use for Goodman equipment and find them to be the most effective and efficient. Readily adjustable operating points at the stat.
    When install costs are...
  23. Thread: Hallowell HPs

    by airon
    Replies
    8
    Views
    884

    Thankyou Gary. There are afew threads on these...

    Thankyou Gary.

    There are afew threads on these units I see.

    They do appear to make sense at low temps ( to -30 deg f) in my area normal mid winter lows to -10. El co-op power costs at .09. Off...
  24. Thread: Hallowell HPs

    by airon
    Replies
    8
    Views
    884

    Hallowell HPs

    Hi does anyone have any direct experience with the Hallowell heat pumps.

    Installed, monitored or have one themselves? Is the cooling side good? does the staging operate on the cooling side?
    Any...
  25. Replies
    15
    Views
    1,627

    Turboaire refrigerated boxes.

    I happen to like these units, especially their prep tables. In comparison to other units built today I think they are better. Some of their low end upright R/ins are as advertised and priced...