Search:

Type: Posts; User: GrumpyPawPaw

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    1,927

    Sorry, need to be a little more specific. "In...

    Sorry, need to be a little more specific.
    "In order to leave the flare connections accessable, I would run the lines to the opposite end of the unit to enter the wall. Right?"
    I am talking...
  2. Replies
    9
    Views
    1,927

    Ductless on interior wall

    We have installed a few ductless units, running the lines directly through an exterior wall. Now looking at installing some indoor wall units on interior walls, so it brings up a few concerns....
  3. Replies
    16
    Views
    2,186

    Dosen't dropbox use the cloud?

    Dosen't dropbox use the cloud?
  4. Replies
    16
    Views
    2,186

    Need a techi geek for ipad

    Got an ipad2, to put a bunch of service manuals etc on. I need step by step instructions on this. Been trying for a couple of weeks. No prob getting the manuals onto the office desk top. (windows) I...
  5. Replies
    102
    Views
    14,917

    PCB's

    Bring back the good ole PCB's. ....on second thought, this is great!!! $$$
  6. Replies
    39
    Views
    5,758

    If bad valves, it wouldn't have returned to...

    If bad valves, it wouldn't have returned to normal pressures.
  7. Replies
    67
    Views
    11,087

    Biggest problem you have, when you are learning...

    Biggest problem you have, when you are learning to use Stay-Brite, is over heating. Hard for you 'blow till it glows' guys !
  8. Replies
    1
    Views
    644

    I guess you are reading from each terminal to...

    I guess you are reading from each terminal to ground? if so: your meter's voltage is building a capacitance until it reaches infinity. Recommend you meg the compressor.
  9. Replies
    39
    Views
    5,758

    My above question applies when the unit is...

    My above question applies when the unit is malfunctioning. I'm assuming the condenser fan was running? Condenser fan shutting off, when your not there? Check fan amps and the cap.
  10. Replies
    39
    Views
    5,758

    Is the suction line very cold? If not I would...

    Is the suction line very cold? If not I would suspect the internal releif valve in the compressor.
  11. Replies
    32
    Views
    3,857

    Tried many tires. We now only run Michelin. With...

    Tried many tires. We now only run Michelin. With brand new tires it is not as bad ....but it gets worse as the tire dosen't wear evenly all around.
  12. Replies
    32
    Views
    3,857

    Here in Texas it dosen't get that cold (except...

    Here in Texas it dosen't get that cold (except when I get near my wife at bedtime):whistle:
    Brakes: 40K miles. We change our own oil(Mobile 1 synthetic) so that cost is not too bad.
    My son loves...
  13. Replies
    29
    Views
    4,770

    Yeah, I'm concerned about cracks due to boat...

    Yeah, I'm concerned about cracks due to boat vibration.
  14. Replies
    32
    Views
    3,857

    've been driving a Freightliner Sprinter since...

    've been driving a Freightliner Sprinter since 2008. Love it! You can stand upright in it, like humans are designed to. When I get something out of one of our econolines, is like crawling into a...
  15. Replies
    32
    Views
    3,857

    I set ours up myself also. eg: the guy (with the...

    I set ours up myself also. eg: the guy (with the butt crack half way up his back) sits on the opposite side from the 7 refrigerant bottles.:LOL:
  16. Replies
    29
    Views
    4,770

    Ability to withstand vibration is another...

    Ability to withstand vibration is another concern. The spine fin condenser coils, for example, vibration will cause the coil of alum tubes to settle 6 to 8 inches, and the bottom tube will rub a hole...
  17. Replies
    58
    Views
    17,494

    Sticky: Poll: Marine/commercial/ industrial

    Marine/commercial/ industrial
  18. Replies
    27
    Views
    4,418

    Completely agree with AlcoMech. Change...

    Completely agree with AlcoMech. Change compressor, install suction dryer. When you get it up and running, you must find what caused the comp failure, or you will be doing it again...just a matter of...
  19. Replies
    29
    Views
    4,770

    Maye if everyone is getting into it, they will...

    Maye if everyone is getting into it, they will put their heads together and work all the bugs out.
  20. Replies
    29
    Views
    4,770

    The advantage of aluminum, to my marine...

    The advantage of aluminum, to my marine customers, is less corrosion. On copper/alum coils, within a couple of years the heat transfer between the alum fins and the copper tubes greatly decreases,...
  21. Replies
    32
    Views
    3,857

    1999 thru 2008, e250 & E350" same prob. Never...

    1999 thru 2008, e250 & E350" same prob. Never could get the balance right. Took em to several places, including truck frame and front end specialty shop.:gah:
    But the alum wheels solved it.:grin2:
  22. Replies
    29
    Views
    4,770

    Thanks! I just ordered some. :cheers:

    Thanks! I just ordered some. :cheers:
  23. Replies
    32
    Views
    3,857

    :eek:Ford puts the rims on their trucks!

    :eek:Ford puts the rims on their trucks!
  24. Replies
    29
    Views
    4,770

    Are you talking about micro-channel or spine fin...

    Are you talking about micro-channel or spine fin type of coils?
  25. Replies
    29
    Views
    4,770

    Still, No good dependable method. Hope the...

    Still, No good dependable method. Hope the manufactures have a easy replacement program, with coils readly avaib!
Results 1 to 25 of 37
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event