  1. Replies
    3
    Views
    738

    thanks for the response. if i decide to take the...

    thanks for the response. if i decide to take the position i would be joining a Johnsons Controls team that runs a facility. so i am sure i would get a good mix of both ends. sounds like since i have...
  2. Replies
    5
    Views
    704

    you are correct. i was mistaken/confused with my...

    you are correct. i was mistaken/confused with my response
  3. Replies
    5
    Views
    704

    we use 2558 on my site. CTL TEMP is whatever your...

    we use 2558 on my site. CTL TEMP is whatever your heating or cooling setpoint is. so if your box is in HEAT mode, CTL TEMP is the heating setpoint. vice versa for COOL mode. i am not familar with...
  4. Replies
    3
    Views
    738

    Going from Siemens to Johnsons

    I am looking to possibly take on a new job in another building. My only experience with controls/building automation has been with siemens. I have gone to several customer classes for siemens and...
  5. Replies
    10
    Views
    1,228

    Does anyone have WCIS?

    Does anyone have WCIS?
  6. Replies
    10
    Views
    1,228

    The application is 2558. BACnet VAV with demand...

    The application is 2558. BACnet VAV with demand control ventilation(CO2) including Chilled beam and floating or analog output.
  7. Replies
    10
    Views
    1,228

    The TEC will control the CWV. Only PPCL i will...

    The TEC will control the CWV. Only PPCL i will need to write is a table statement for the dewpoint sensor that will be hooked up to AI3.
  8. Replies
    10
    Views
    1,228

    yeah Im adding a CW zone valve for chilled beams....

    yeah Im adding a CW zone valve for chilled beams. all the VAVs on our site were flashed by siemens over the summer with the same application to speed up the PID loop for chilled water. I have been...
  9. Replies
    10
    Views
    1,228

    i already have the MIN and MAX CFM settings put...

    i already have the MIN and MAX CFM settings put in the TEC and on the initial values. it does have a flow tube with Hi and Lo going back to the TEC. i suppose my only real concern is setting up the...
  10. Replies
    10
    Views
    1,228

    first VAV start up

    Need a little help.

    company i work for is doing an inhouse renovation project. took a room that was used for file storage and making it into a workspace. we demo'ed out the old VAV, and put in a...
  11. Replies
    3
    Views
    679

    when first opening the graphic, do the points...

    when first opening the graphic, do the points have the intial value when opened? or the values not showing up at all?
  12. Replies
    14
    Views
    1,083

    turns out the intial values were set up wrong....

    turns out the intial values were set up wrong. one TEC intial value for CRTLADDRESS was 70 and the other was 0.
  13. Replies
    14
    Views
    1,083

    thats what ive done the last few times with...

    thats what ive done the last few times with system activity log. esp with the one that goes to 70. nothing comes up. only other thing would be someone is hooking up to the TEC directly and changing...
  14. Replies
    14
    Views
    1,083

    Siemens Apogee with BACnet IP. Most FLN devices...

    Siemens Apogee with BACnet IP. Most FLN devices are MS/TP. The TECs and Field Panels are BACnet.
  15. Replies
    14
    Views
    1,083

    that along with the facility i work in is run on...

    that along with the facility i work in is run on battery backup until generators kick in so i dont ever loose power to devices. i would go along the lines of it being some MS/TP network fluke.
  16. Replies
    14
    Views
    1,083

    BACnet you can change the address(subpoint#1)...

    BACnet you can change the address(subpoint#1) through global commander. I know someone had changed the one once on accident. then i had to goto the room sensor and plug into the TEC to change it back...
  17. Replies
    14
    Views
    1,083

    neither loses its application. one goes to 70...

    neither loses its application. one goes to 70 (like someone messed up in global commander trying to change a setpoint) and the other has gone back to 0. I know that the one that has gone to 70 is not...
  18. Replies
    14
    Views
    1,083

    TEC losing control address

    had a few TECs loose their control address several times the last few months. at first i was thinking this was due to some of the operators accidently commanding the address instead of setpoints. i...
  19. Replies
    134
    Views
    26,579

    CIS please Email Address Removed

    CIS please

    Email Address Removed
  20. Replies
    0
    Views
    287

    TerminalServicesManager

    Recently just added a a new workstation into our network. We used to just remote into our DNS to get into Insight. Now that we have a new workstation we are not able to send messages to eachother...
  21. Replies
    1
    Views
    403

    Trending Issues

    First Post.

    We've been having an issue on our site with DataAire CRUs not giving us proper trending data. about 2 years ago the trending info we got was good. nothing has changed from two years...