01-06-2013, 02:04 PM
Thread: Data Center Critical Cooling
by Cold shot- Replies
- 15
- Views
- 1,447
May have got away with it using 22, but never...
May have got away with it using 22, but never with 410 & POE oil. We fix a lot of these after poor install. Purge with nitro during all pipe work. Triple evac & use ACCURATE micron gauge.
ONLY... -
01-06-2013, 01:59 PM
Thread: Data Center Critical Cooling
by Cold shot- Replies
- 15
- Views
- 1,447
410a systems are even more prone to clogging LL...
410a systems are even more prone to clogging LL driers.
-
01-06-2013, 01:56 PM
Thread: Data Center Critical Cooling
by Cold shot- Replies
- 15
- Views
- 1,447
APC, Stulz, Data Aire... All are inferior to...
APC, Stulz, Data Aire... All are inferior to Liebert in my opinion.
Also, in-row cooling designs are the way to go.
LIEBERT IS THE CADILLAC OF CRITICAL ROOM COOLING! -
01-06-2013, 01:45 PM
Thread: Trane Voyager Condenser Fan Problems
by Cold shot- Replies
- 18
- Views
- 1,809
I have not seen that before, interesting. Must...
I have not seen that before, interesting. Must have a second contactor to run fan in opposite direction.
-
01-01-2013, 01:48 PM
Thread: Carrier RTU
by Cold shot- Replies
- 24
- Views
- 2,016
True, but there are several things that can be...
True, but there are several things that can be added. Air proving switch, freeze stat, low & high pressure switches, discharge line thermostats, phase monitors. All to protect the compressor.
-
12-31-2012, 05:07 PM
Thread: Carrier RTU
by Cold shot- Replies
- 24
- Views
- 2,016
Economizer would disable 1st stage mechanical...
Economizer would disable 1st stage mechanical cooling if outdoor conditions were suitable (sounds like they are) for free cooling. Suction line freeze stat on 2nd stage compressor or Low ambient...
-
12-31-2012, 05:00 PM
- Replies
- 2
- Views
- 508
Is it a semi-hermetic?
Is it a semi-hermetic?
-
12-31-2012, 04:58 PM
Thread: Silfos rings...
by Cold shot- Replies
- 10
- Views
- 1,305
Tried to get guys to use this at our company,...
Tried to get guys to use this at our company, they were too OLD SCHOOL. I think these rings eliminate using too much Silfos on joints (a lot of techs do this to make sure no leaks). Also works very...
-
12-31-2012, 04:54 PM
Thread: Trane Voyager Condenser Fan Problems
by Cold shot- Replies
- 18
- Views
- 1,809
Carrier 38AKS condensing units with 2 fans do...
Carrier 38AKS condensing units with 2 fans do this too. #2 fan rotates backwards while #1 runs, when #2 is energized, it continues to run in wrong direction. A new capacitor fixes this.....for a...
-
12-31-2012, 04:50 PM
Thread: VRF Systems - Would you recommend one?
by Cold shot- Replies
- 11
- Views
- 1,033
Poll: Our company learned this the hard way...
Our company learned this the hard way too......MITSUBISHI'S ARE THE ONLY MINI SPLIT & VRF'S WE INSTALL NOW! CITY MUTI IS A GREAT PRODUCT.
-
12-31-2012, 12:00 PM
Thread: multi-city units
by Cold shot- Replies
- 13
- Views
- 1,413
Use a high quality electronic vacuum gauge (not...
Use a high quality electronic vacuum gauge (not your $100 variety). Gotta trust your tools!
-
12-31-2012, 11:25 AM
Thread: Calculating GPM
by Cold shot- Replies
- 29
- Views
- 2,048
Find the cooler gpm in the Manufacturers IOM...
Find the cooler gpm in the Manufacturers IOM book. There will be a minimum & maximum GPM graph where you can plot your FT./head. You will need to get cooler entering water psi & cooler leaving...
-
12-31-2012, 11:10 AM
Thread: multi-city units
by Cold shot- Replies
- 13
- Views
- 1,413
I have installed 3 of the City Multi systems- a...
I have installed 3 of the City Multi systems- a great tip is to inventory your refrigerant tubing (lengths) & save the unused pieces from each branch line. Measure those left over pieces & subtract...
-
12-31-2012, 11:02 AM
Thread: multi-city units
by Cold shot- Replies
- 13
- Views
- 1,413
Just use a good recovery machine & keep recovery...
Just use a good recovery machine & keep recovery tanks cool.
-
12-31-2012, 11:01 AM
Thread: Arc flash training
by Cold shot- Replies
- 20
- Views
- 2,057
Personally, I use my rubber gloves & leather...
Personally, I use my rubber gloves & leather protector gloves when I feel it is necessary. Mostly when I am working inside an electrical panel, motor starter control cabinet etc. Also voltage...
-
12-31-2012, 10:45 AM
Thread: Heat pump Acid test.
by Cold shot- Replies
- 13
- Views
- 933
Burnouts in Heat Pumps are very troublesome...
Burnouts in Heat Pumps are very troublesome because of the possibility of getting debris in the check valves, reversing valve etc. I would encourage the customer to replace the unit before heading...
-
12-31-2012, 10:41 AM
Thread: Heat pump Acid test.
by Cold shot- Replies
- 13
- Views
- 933
I use Acid Away & install suction & liquid line...
I use Acid Away & install suction & liquid line replaceable core driers w/ HH cores. Run system for a couple days, remove suction core, replace liquid line core drier with standard core drier & run...
-
12-31-2012, 10:32 AM
Thread: GCS3 ignition failure
by Cold shot- Replies
- 11
- Views
- 1,024
Time for a new RTU!
Time for a new RTU!
-
I was referring to the Challenger & Minimates. I...
I was referring to the Challenger & Minimates. I have worked on the ICOM In-Row with digital scroll R410 & 407C. I have not been to the ICOM class yet.
-
Lieberts very good machines & are easy to work on.
Lieberts very good machines & are easy to work on.