05-19-2012, 07:29 PM
- Replies
- 6
- Views
- 717
What were your pressures? Air cooled? Cycling...
What were your pressures? Air cooled? Cycling cond fan? Headmaster?
Head pressure change? We're you measuring at the comp leads or breaker? -
05-03-2012, 08:48 PM
Thread: Compressors tripping
by Senior1- Replies
- 6
- Views
- 559
Agree
Agree
-
05-02-2012, 12:44 PM
Thread: Need help with 3 phase power
by Senior1- Replies
- 54
- Views
- 2,544
You are reading a voltage drop across a load like...
You are reading a voltage drop across a load like a CCH, wired to line side of contactor. Meter making the circuit, or grounded side of control transformer.
-
04-26-2012, 09:01 PM
Thread: Duct Sizing---Again
by Senior1- Replies
- 10
- Views
- 832
Old rule of thumb! RA=, 1 sq ft/ton@400cfm/ton
Old rule of thumb! RA=, 1 sq ft/ton@400cfm/ton
-
04-26-2012, 08:42 PM
Thread: HVAC guy needing Comm ref Mech Help
by Senior1- Replies
- 42
- Views
- 1,816
Nail head, meet hammer, ;-)
Nail head, meet hammer, ;-)
-
04-26-2012, 08:29 PM
Thread: Confused and Frustrated
by Senior1- Replies
- 35
- Views
- 1,806
Thought we were talking a/c, my bad.
Thought we were talking a/c, my bad.
-
04-26-2012, 08:26 PM
Thread: Confused and Frustrated
by Senior1- Replies
- 35
- Views
- 1,806
Remember, more moisture removal=less dry blub...
Remember, more moisture removal=less dry blub temp split. (latent vs sensible stuff)
That said, generally, slightly low sub cooling and slightly high superheat
= slightly low freon. Ya, need wet... -
04-26-2012, 08:06 PM
Thread: Confused and Frustrated
by Senior1- Replies
- 35
- Views
- 1,806
Does not compute........ Adding heat to evap...
Does not compute........ Adding heat to evap increases subcooling?
-
04-26-2012, 07:49 PM
Thread: HVAC guy needing Comm ref Mech Help
by Senior1- Replies
- 42
- Views
- 1,816
newbie here, common suction? How is the oil...
newbie here, common suction? How is the oil separator piped and is the oil pressure switch wired correctly? Unloading? Staged? Pump down or selinoid drop? Just thinking out loud.
-
04-25-2012, 08:17 AM
- Replies
- 7
- Views
- 525
Manufactures could care less how hard it is for...
Manufactures could care less how hard it is for you to get that info. They would rather you sell a unit.
Careers are made at the factory level by saving a nickel per unit.
Another question,... -
04-22-2012, 09:44 AM
Thread: High super heat.
by Senior1- Replies
- 34
- Views
- 2,861
high superheat an low SC,,, add two lbs and get...
high superheat an low SC,,, add two lbs and get back to us. Remember a txv is a constatant superheat device, if you add freon and the SH starts going down, you were flashing in the LL . 40 ft is...
-
04-22-2012, 09:36 AM
Thread: AC Tune Up
by Senior1- Replies
- 123
- Views
- 4,643
feast and famine, nature of the beast, did it for...
feast and famine, nature of the beast, did it for decades, save in the summer, hunt n fish in the spring fall.
We even hade one tech that would go to job sites and let freon out systems so he... -
04-19-2012, 07:50 PM
- Replies
- 15
- Views
- 814
Walmart window unit in the bedroom is your...
Walmart window unit in the bedroom is your friend. I keep an old one in the garage, same price as putting wifey up in a motel for one night.
-
04-19-2012, 07:18 PM
Thread: 410a moisture issues.
by Senior1- Replies
- 15
- Views
- 1,168
Hygroscopic =hyDroscopic, damn computer!
Hygroscopic =hyDroscopic, damn computer!
-
04-19-2012, 07:15 PM
Thread: 410a moisture issues.
by Senior1- Replies
- 15
- Views
- 1,168
Which is the reason I recommend HOs that have a...
Which is the reason I recommend HOs that have a good r22 system keep them. POE are bad juju with moisture. Did anyone mention POEs are 5 times more hygroscopic as mineral oil. (or was that 10 times)
-
04-19-2012, 06:51 PM
Thread: SEER in the real world.
by Senior1- Replies
- 27
- Views
- 1,226
You are correct, same in the south. Clean the...
You are correct, same in the south.
Clean the cond/evap/blower wheel of an old system, you just saved the same amount as new system. (all else being same, correct charge, air flow,etc.)
I have... -
04-18-2012, 10:35 PM
Thread: Lennox HS-21 Help
by Senior1- Replies
- 16
- Views
- 870
LOL,,that made me laugh, I remember a GE RTU,...
LOL,,that made me laugh, I remember a GE RTU, about 50 ton HP in the 80's or so, opened the panel and all black wires with 30 relays:gah:
-
04-18-2012, 09:52 PM
Thread: AC Tune Up
by Senior1- Replies
- 123
- Views
- 4,643
Yep, big company I worked for had high school...
Yep, big company I worked for had high school kids doing PMs, and polishing the OD unit so it looked like they did something. Old people, I do many for free on my time.
-
04-18-2012, 09:47 PM
Thread: AC Tune Up
by Senior1- Replies
- 123
- Views
- 4,643
Heating,,, gas,,,,PM? Yes, Have a good night ;-)
Heating,,, gas,,,,PM? Yes, Have a good night ;-)
-
04-18-2012, 09:07 PM
Thread: AC Tune Up
by Senior1- Replies
- 123
- Views
- 4,643
Delta t CHANGE on a known working system is good...
Delta t CHANGE on a known working system is good info for the home owner to monitor THEIR system, any change, call me.
The problem is we techs have been pushed to SELL, SELL,SELL! The high seller... -
04-18-2012, 07:59 PM
- Replies
- 16
- Views
- 908
LOL,,, I have seen leaving the txv bulb hanging...
LOL,,, I have seen leaving the txv bulb hanging out in the attic considered a fix by some:gah:
-
04-18-2012, 07:36 PM
Thread: AC Tune Up
by Senior1- Replies
- 123
- Views
- 4,643
Forgot to add, I have seen just as many new...
Forgot to add, I have seen just as many new system failures as old.
-
04-18-2012, 07:24 PM
Thread: AC Tune Up
by Senior1- Replies
- 123
- Views
- 4,643
You just stated the problem, most RESIDENTIAL...
You just stated the problem, most RESIDENTIAL PM's are for cash flow only. I'm sorry to jump in late, but I agree with Flash, I also have over 20 yrs exp.
If you have an old draft type gas... -
04-15-2012, 05:08 PM
Thread: Checking airflow
by Senior1- Replies
- 25
- Views
- 1,632
Heat rise is good for ele heat fan coils except...
Heat rise is good for ele heat fan coils except in the summer. If its 95 outside and you are troubleshooting, last I want to do is heat the customers already hot house up more. I have a electronic...
-
04-14-2012, 01:57 PM
Thread: Assessing heat pump chagre (winter)
by Senior1- Replies
- 21
- Views
- 869
Carrier heating check chart, model will change...
Carrier heating check chart, model will change info of course.
http://www.xpedio.carrier.com/idc/groups/public/documents/techlit/38ydb-1xa.pdf
Ps, read small print