Search:

Type: Posts; User: Boise500

Search: Search took 0.01 seconds.

  1. My thoughts about the superheat should be lower. ...

    My thoughts about the superheat should be lower. I believe the valve will ignore the load, and will strive to maintain the superheat setting of the valve. I left the superheat setting at 10...
  2. Gentlemen, thank you so much for you input. I...

    Gentlemen, thank you so much for you input. I talked to the Randell Factory again this morning. The first conversation since new gas, tev,...etc. They explained the manufacturing process of this...
  3. Pressure reading at comp, five feet of line from...

    Pressure reading at comp, five feet of line from evap outlet, using 3 month old Fluke 52 II with clamp on probe, on sanded clean suction line.

    Randell explained the circuitry to me.

    Liquid line...
  4. The only tiny fan in the static rail, is in a 12"...

    The only tiny fan in the static rail, is in a 12" box, that sits loose in the rail, and plugs into an electrical socket in the rail wall. When plugged in, it also closes a circuit which allows a...
  5. Randell says the air temp in the rails should be...

    Randell says the air temp in the rails should be 25 - 30 degrees, it is running at about 50 degrees. They have all the holes filled. And stock with pre-cooled pans.
  6. Prep table raised rail starving/serpentine separation?

    Working on a Randell Model 8411M, 111" long, 4 lower doors and full length raised rail. Original tag says 134A, but has R404 comp and tev's. Bottom works fine. With the bottom stat turned off, so...
  7. Replies
    18
    Views
    2,725

    Your statement: After initial harvest, the right...

    Your statement: After initial harvest, the right side evap takes a couple cycles to build ice and then harvest seems more difficult (evap doesnt seem to get hot enough to dump ice). Is this normal?
    ...
  8. Replies
    4
    Views
    652

    Supco even has the best info of cap suppliers, in...

    Supco even has the best info of cap suppliers, in each package.
  9. Thread: Anthony Doors

    by Boise500
    Replies
    9
    Views
    2,395

    There is a learning curve on Anthony doors. The...

    There is a learning curve on Anthony doors. The people at Anthony is also challenging. Check the Manufacturing Date in the glass, to help with what series you are working on, if they are old.
  10. Replies
    13
    Views
    1,342

    WI freezers don't have to pump down to defrost. ...

    WI freezers don't have to pump down to defrost. The liquid in the evap will turn to gas. Some manufacturers put in a solenoid just for cheap insurance in case the tev doesn't seat on shut down.
  11. Replies
    8
    Views
    749

    What was the outcome???

    What was the outcome???
  12. Replies
    14
    Views
    1,492

    Sometimes a balanced port valve can be a little...

    Sometimes a balanced port valve can be a little to responsive, if it hunts, add a layer of electrical tape between the bulb and the suction line. After you rule the normal causes out.
  13. Replies
    39
    Views
    2,875

    Some people top off R12 systems with hotshot, and...

    Some people top off R12 systems with hotshot, and have experienced no problems.
  14. Replies
    6
    Views
    547

    also check to make sure you're not adding water...

    also check to make sure you're not adding water continuously, that would keep the water from getting cold fast enough.
  15. Please post your outcome, when you get to the...

    Please post your outcome, when you get to the bottom of your water problem.
  16. Replies
    4
    Views
    696

    Measuring length and diameter is ok, if using...

    Measuring length and diameter is ok, if using original refrigerant.
  17. Replies
    22
    Views
    2,110

    If anyone finds the specs on when the different...

    If anyone finds the specs on when the different oil break down, please post it. Thanks
  18. Thread: freezer floor

    by Boise500
    Replies
    10
    Views
    1,164

    We took care of the problem by riveting down some...

    We took care of the problem by riveting down some aggressive non slip metal, more money, but permanent.
  19. Thread: Hoshizaki KM

    by Boise500
    Replies
    7
    Views
    574

    A Hoshi that has had high head, or high evap...

    A Hoshi that has had high head, or high evap defrost temps, have been known to have the evap separate, your might want to check this just to cya.
  20. Thread: Rental car

    by Boise500
    Replies
    15
    Views
    1,165

    Driving a strange car in a strange environment,...

    Driving a strange car in a strange environment, might be an additional consideration.
  21. Replies
    21
    Views
    2,252

    Do Over, you sound like a perfectionist, not a...

    Do Over, you sound like a perfectionist, not a bad thing.
  22. Thread: Black Mold

    by Boise500
    Replies
    16
    Views
    1,670

    The EPA has instructions for the homeowner to...

    The EPA has instructions for the homeowner to clean up less than 35sq ft of mold. Mold is usually only harmful if someone has an allergy. Main issues, put structure in a negative air balance, kill...
  23. Replies
    9
    Views
    2,587

    Should your system dry out the air to much, build...

    Should your system dry out the air to much, build a 3/16" dam with silicone around the evap drain hole. This will help some of the condensate to re-evaporate into the air.
Results 1 to 23 of 23