  1. Replies
    10
    Views
    1,052

    I have an older 3.6 version. We have been phasing...

    I have an older 3.6 version. We have been phasing out Siemens and replacing it with Automated Logic. I have seen the new adapt statement, but cannot implement it in my facility.
  2. Replies
    2
    Views
    329

    I use pressure switches or transmitters just...

    I use pressure switches or transmitters just because of pricing. Most are hardwired to shut off booster pumps and broadcast alarms.
  3. Replies
    10
    Views
    1,052

    I assign virtual points to the P, I, and if used...

    I assign virtual points to the P, I, and if used D so I can tune the loop without re-downloading program. Become good friends with the dynamic plotter. It has helped me tune many loops as long as you...
  4. Replies
    4
    Views
    441

    Ok. I didn't know it ran as a service. Thanks!

    Ok. I didn't know it ran as a service. Thanks!
  5. Replies
    4
    Views
    441

    I believe I am using version 3.6. Do you recall...

    I believe I am using version 3.6. Do you recall how to disable the printer service?
  6. Replies
    4
    Views
    441

    Siemens/Insight printer question

    This is probably an easy one for the Insight gurus. I have a system that uses a dot matrix printer to print BLN alarms and messages. The paper is becoming quite expensive and hard to find. I want to...
  7. Replies
    37
    Views
    2,917

    I have used almost every control system...

    I have used almost every control system available. I recommend Automated Logic. My local dealer is great.
  8. Replies
    2
    Views
    431

    I agree. Don't change the name. IT pushed the...

    I agree. Don't change the name. IT pushed the same thing on me 2 years ago. It was a nightmare.
  9. Replies
    10
    Views
    970

    Got it! I had to add the tec with a Laptop....

    Got it! I had to add the tec with a Laptop. System profile kept rejecting it. Thanks
  10. Replies
    10
    Views
    970

    After I create my TEC and address it, what do I...

    After I create my TEC and address it, what do I put in the blank drop-down box for applications? It makes me select one before I can add the TEC to the FLN.
  11. Replies
    10
    Views
    970

    Thanks again. I only need to send the drives an...

    Thanks again. I only need to send the drives an input reference for speed command. Everything else is hardwired. I have no AO's so I'm stuck getting the FLN to work. I'll look for that application.
  12. Replies
    10
    Views
    970

    I will certainly try tomorrow. The default on...

    I will certainly try tomorrow. The default on adding a new TEC is blank. I do not recall any applications starting with a 6, but I will check. Thanks for the advice.
  13. Replies
    10
    Views
    970

    Built TEC on system profile, but it makes me...

    Built TEC on system profile, but it makes me select an application before I can add it. I added the only drive application I had. I believe it was 2734, but it didn't work.
  14. Replies
    10
    Views
    970

    Siemens Apogee FLN application 2721

    I networked two Yaskawa E7U drives on an FLN today, and I have no comm errors. However, I need application 2721 to map the points. Is there anyway to get this application? If I do get it, how do I...
  15. Replies
    4
    Views
    1,224

    The only programs I have on my disk are sitebook,...

    The only programs I have on my disk are sitebook, cf connect, cf terminal, m-alarm, m-password, m3 workstation, m-authorize, m-collector, m-explorer, m-graphics, modempro, and m-trend. Looks like I...
  16. Replies
    4
    Views
    1,224

    Retrieving my database in Johnson Controls

    Hello all! I work at a facility that has Siemens, ALC, and Johnson Controls. Needless to say I suck at Johnson Controls. I recently lost my hard drive on my Johnson Controls pc, and I had to...
  17. Thread: Datamate

    by Montani
    Replies
    1
    Views
    437

    Datamate

    Hello!

    My Datamate disk broke and I need to install it on a new laptop. I need to communicate with some Siemens TEC's. Can anyone hook me up? Is there a better program I can use instead?
  18. Replies
    0
    Views
    759

    Buffalo Forge Trye VPS Return Fan

    Hello!

    I am trying to calibrate return fan vanes and need some advice if anyone knows!

    Buffalo Forge Type "VPS" Adjustax Controllable Pitch Vaneaxial Fan
    Size 33BS
    Serial 86300735
    Max Blade...
  19. Replies
    32
    Views
    2,671

    Me812u with or without the lgr.

    Me812u with or without the lgr.
  20. Thread: HVACPro Gurus!

    by Montani
    Replies
    8
    Views
    900

    Thanks. Anyone have a newer copy? Im also looking...

    Thanks. Anyone have a newer copy? Im also looking for datamate.
  21. Thread: HVACPro Gurus!

    by Montani
    Replies
    8
    Views
    900

    Thanks! Is it freeware?

    Thanks! Is it freeware?
  22. Thread: HVACPro Gurus!

    by Montani
    Replies
    8
    Views
    900

    HVACPro Gurus!

    Hello!
    I have HVACPro v. 8.03. I am running it on windows XP. When I connect to an N2 cabinet it freezes my laptop. I am able to see the current values, its just locked up. Is there a newer version...
  23. Replies
    13
    Views
    777

    That did it! Tera Term works great! Thank you...

    That did it! Tera Term works great! Thank you Paul_C!
  24. Replies
    13
    Views
    777

    Drivers

    Yes, windows xp drivers.
  25. Replies
    13
    Views
    777

    Siemens comm help!

    Hello! I am trying to phase out my old laptops and bought a new dell with windows xp. I got a brand new radio shack rs232 to usb converter, and a new rj11 to rs232 converter. I set up hyperterminal...
Results 1 to 25 of 25