Search:

Type: Posts; User: klrogers

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Thread: Jace and SMS

    by klrogers
    Replies
    0
    Views
    121

    Jace and SMS

    Anyone using and can recommend a good external serial GPRS modem for use with a Jace to send SMS messages? We are currently using the Tridium supplied internal modem with a wireless SIM card and high...
  2. 522421Set up an alarm class lets say...

    522421Set up an alarm class lets say "BoilerFailAlarmClass", then route that to your email recipient (and console recipient usually). Use this new class it the set up of your alarm extension.
  3. +1, pity we can't do N2 tunnelling ;)

    +1, pity we can't do N2 tunnelling ;)
  4. You have to create identical alarm classes in...

    You have to create identical alarm classes in both the Jace and the Supervisor to use 'use existing'
  5. Do you have %alarmData.msgText% in the body of...

    Do you have %alarmData.msgText% in the body of your email recipient?

    Kevin
  6. Thread: HVAC Pro

    by klrogers
    Replies
    21
    Views
    711

    Get the B&B USOPTL4 and you can then connect...

    Get the B&B USOPTL4 and you can then connect directly on the N2 network, you should disconnect any other supervisory controls from the network, i.e. N30, FX60 etc. If you want to connect using the...
  7. 521031 Change the "Replace" with "Use...

    521031

    Change the "Replace" with "Use existing"

    Kevin
  8. Thread: HVAC Pro

    by klrogers
    Replies
    21
    Views
    711

    I have heard that some guys have been able to...

    I have heard that some guys have been able to install it on Windows 7, but that might have been a 32 bit version of Win 7. Myself I put it on a virtual machine (VmWare) running XP. Not sure if it...
  9. Thread: Economizers

    by klrogers
    Replies
    5
    Views
    519

    Try this for starters ...

    Try this for starters

    http://www.virginiaair.com/index.php/contractors/documents/hot-sheets/doc_download/462-honeywell-economizer-troubleshooting

    Kevin
  10. Replies
    2
    Views
    205

    Should be as simple as animating the background...

    Should be as simple as animating the background property of the bound label, right click on it, choose animate, choose boolean to simple, choose colors for True and false.

    Kevin

    EDIT: if you...
  11. Replies
    1
    Views
    235

    If you had access to the Vykon Pro module then...

    If you had access to the Vykon Pro module then there is a built in module that would do the job.

    515971

    515981


    Kevin
  12. Replies
    5
    Views
    396

    I see your are in Virginia, and you are talking...

    I see your are in Virginia, and you are talking about Southeast, do you mean Southeast Virginia, if so are you talking about Damuth Trane?

    Kevin
  13. Replies
    13
    Views
    291

    I know of such commands for Ax Jaces, not sure if...

    I know of such commands for Ax Jaces, not sure if there is such a thing for R2 ones, the Ax ones are not recommended to be used according to the powers that be, they should be used only as a last...
  14. Replies
    2
    Views
    195

    For the first question, you could modify the...

    For the first question, you could modify the setpoint checkbox widget from kitPx to achieve the required actions, just take any the checkbox graphic and use a normal button to toggle between...
  15. Replies
    12
    Views
    357

    Make sure that you enter the facet is '...

    Make sure that you enter the facet is ' maxOverrideDuration' note the first letter is in lowercase, small things like that can throw you for a loop.

    Kevin
  16. Replies
    6
    Views
    588

    One of many options might be...

    One of many options might be http://www.pelicanwireless.com/

    Kevin
  17. I think that ones level of access controls who...

    I think that ones level of access controls who can use that feature, I don't have that ability.

    Kevin
  18. Replies
    17
    Views
    1,064

    Exact Logic have a good range of BACnet...

    Exact Logic have a good range of BACnet compatible thermostats, I can't comment on their quality having never used them.

    https://www.exactlogic.com/BACNet

    Kevin
  19. Thread: Lon Plug

    by klrogers
    Replies
    12
    Views
    607

    Check the dimensions, but I think this is...

    Check the dimensions, but I think this is probably the right one: http://www.digikey.com/product-detail/en/OSTTJ0211530/ED10554-ND/1588359
  20. Replies
    13
    Views
    763

    OK ascj, please forward them to me, I will pass...

    OK ascj, please forward them to me, I will pass on to the next requester.

    Kevin
  21. Replies
    32
    Views
    1,376

    See: ...

    See: http://www.industrialcontrolsonline.com/pdf/specifications/family2362-specifications.pdf

    Shows that 16g is an option.

    Kevin
  22. Replies
    6
    Views
    442

    If you have full access to Niagara Central: ...

    If you have full access to Niagara Central:

    https://community.niagara-central.com//ord?portal:/dev/wiki/PxPages_Fail_to_Load_After_Installing_Java_7_Update_65

    3.7.106 must be fully up to date...
  23. Replies
    29
    Views
    1,487

    I recently got a service/utility cart similar to...

    I recently got a service/utility cart similar to Osiyo's, a bit smaller and probably not of the same quality. http://www.northerntool.com/shop/tools/product_200344165_200344165 I am thinking of...
  24. Replies
    29
    Views
    1,487

    Well not withstanding their claims, I don't think...

    Well not withstanding their claims, I don't think I would want to risk putting my laptops that close to powerful magnets.

    Kevin
  25. Replies
    29
    Views
    1,091

    Is it possible that the port got changed during...

    Is it possible that the port got changed during commissioning?

    Kevin
  26. Replies
    33
    Views
    4,612

    At least it said "at least 486" if it said a 486...

    At least it said "at least 486" if it said a 486 processor must be provided, then you would had a job finding a suitable computer.
  27. Replies
    36
    Views
    1,506

    Using chrome v35 or 36 site seems to be...

    Using chrome v35 or 36 site seems to be constantly loading and times out. Firefox seems OK.
  28. Is the XP operating system recognizing the...

    Is the XP operating system recognizing the network card in the new computer? Have you changed the driver for the network card to one for the new computer? Is the network card in Summit set to look at...
  29. Replies
    3
    Views
    399

    It has to be done via your support channel,...

    It has to be done via your support channel, Project and Owner are embedded in the license file, any attempt to change the license file will cause the license to become invalid.

    Kevin
  30. Replies
    7
    Views
    334

    wireless + historical building = lots of...

    wireless + historical building = lots of headaches, be prepared to install lots of repeaters, wireless gateways etc.

    Kevin
  31. Hardware all VFD's, and if connected to comm ...

    Hardware all VFD's, and if connected to comm wire that is a separate trunk from the other controllers. Too often comm wires connected to VFD's even when done exactly to manufacturer's and protocol...
  32. Replies
    5
    Views
    477

    Not sure that the T775 was ever networkable

    Not sure that the T775 was ever networkable
  33. Thread: Intellastar

    by klrogers
    Replies
    6
    Views
    407

    Intellastar

    Anyone had anything to do with these people: https://www.intellastar.com/

    Any feedback from anyone is welcome, I have been asked by upper management to see if it's something we should look into,...
  34. Replies
    6
    Views
    516

    I'm sure cutting the barrel plug off does wonders...

    I'm sure cutting the barrel plug off does wonders for the UL listing ;)

    Kevin
  35. Replies
    2
    Views
    914

    I'm not an expert, but I do have some ISN stuff...

    I'm not an expert, but I do have some ISN stuff for sale if you need anything, this is pre-Connexsys stuff.

    Kevin
  36. Replies
    15
    Views
    805

    Check out ...

    Check out http://www.bb-elec.com/Products/USB-Connectivity/USB-to-Serial-Adapters/Mini-USB-to-Serial-Converters.aspx

    Also read up on the locked serial number, it can help when you have several...
  37. Thread: LG V-net

    by klrogers
    Replies
    20
    Views
    1,627

    + 1

    + 1
  38. The way I would deal with this would be to use a...

    The way I would deal with this would be to use a pxInclude for one of the controllers, or indeed both of the controllers. What I mean by that is put all the points from controller A on pxA and points...
  39. Replies
    4
    Views
    248

    I have never had that problem, but remember...

    I have never had that problem, but remember reading a while back that the installation must be done using a windows login that has full administrator privileges. Installing the software has a regular...
  40. It is certainly a complex set of calculations to...

    It is certainly a complex set of calculations to figure out the correct OA with any VAV system.

    This link will get you two spreadsheets that MIGHT help, I can't help you with using them, but my...
  41. Personally I would use an adjustable current...

    Personally I would use an adjustable current sensing switch.

    Kevin
  42. Replies
    8
    Views
    619

    Looks advanced for the timeframe.

    Looks advanced for the timeframe.
  43. Replies
    5
    Views
    391

    OK, so that anyone having this problem in the...

    OK, so that anyone having this problem in the future knows, it is a simple fix, the points have to have a "short name" not just DO1, AI2, or similar. Don't ask me way it will import AO's without a...
  44. Replies
    5
    Views
    391

    The Reaper took my DMO files and successfully...

    The Reaper took my DMO files and successfully imported them in a station using the FX workbench, he also took a copy of my station, run that on a FX workbench and could successfully import the DMO...
  45. Replies
    5
    Views
    391

    FX60 DMO File import

    Working on a project that is replacing an N30 with a FX60, not at job site yet but I do have the PRN and DMO files.

    I can get the PRN files to import and all the points seem to show up, but when I...
  46. Thread: best lap top

    by klrogers
    Replies
    30
    Views
    1,199

    Depending on the software you are using, a native...

    Depending on the software you are using, a native serial port (RS232) might be needed, sometimes a usb to RS232 adapter just does not cut it. Not many laptops are available with a true RS232 port...
  47. Replies
    21
    Views
    1,397

    What nobody carries a Simpson 260 in their tool...

    What nobody carries a Simpson 260 in their tool pouch these-days :) I don't carry one, but still sometimes use one on the bench. But the most important feature of any meter is the the user trusts...
  48. Replies
    8
    Views
    722

    Not trying to take over from Control Geek, but I...

    Not trying to take over from Control Geek, but I believe he means:

    Demand Controlled Ventilation usually using CO2 sensors to control amount of ventilation air as opposed to fixed amounts.
    ...
  49. Replies
    10
    Views
    676

    And 3.8 as the ability to import SVG graphics,...

    And 3.8 as the ability to import SVG graphics, not had a chance to play with that yet, but don't expect any great ability to produce inter-active gauges or graphs.

    Kevin
  50. Replies
    10
    Views
    676

    If you have access to Niagara Central here is the...

    If you have access to Niagara Central here is the link:

    https://community.niagara-central.com/ord?portal:/blog/BlogEntry/232

    Kevin
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event