Search:

Type: Posts; User: Alantoy13

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    7
    Views
    526

    I've had one in my home unit since 2010 with no...

    I've had one in my home unit since 2010 with no problems yet. If you have a 14 inch wide furnace it's going to be a tight fit. Mine is in a lennox g40 series. Nice quiet motors.
  2. Replies
    7
    Views
    526

    I've had one in my home unit since 2010 with no...

    I've had one in my home unit since 2010 with no problems yet. If you have a 14 inch wide furnace it's going to be a tight fit. Mine is in a lennox g40 series. Nice quite motors.
  3. Replies
    16
    Views
    1,108

    Wouldn't matter at that point. The motors already...

    Wouldn't matter at that point. The motors already bad so it's worth the effort to try.
  4. Replies
    16
    Views
    2,254

    I like the fill the drum idea, maybe 2 5 gallon...

    I like the fill the drum idea, maybe 2 5 gallon buckets would be more practical?


    Doesnt work like that with an open pipe, there is no pressure on it so that would be free flow. You must have a...
  5. Replies
    12
    Views
    1,439

    You should have saw this coming and ran for the...

    You should have saw this coming and ran for the hills before you started even repairing anything chiller warranty related. Better yet you get what you deserve trying to think that you could beat out...
  6. Replies
    6
    Views
    1,433

    Ya know gauge hoses, manifolds, and hose seals...

    Ya know gauge hoses, manifolds, and hose seals all play a fairly large part in a good micron gauge and a bad one. Check them first!
  7. Replies
    5
    Views
    878

    Carpet fans.... very inventive!

    Carpet fans.... very inventive!
  8. Replies
    6
    Views
    895

    I've had to replace a lot of boards on the xp14...

    I've had to replace a lot of boards on the xp14 xp15 and xp19 because they never would bring on defrost or I would get continuity through R & Y1.
  9. Replies
    4
    Views
    449

    They make duct wrap go to a home improvement...

    They make duct wrap go to a home improvement store and ask an associate.
  10. I've only seen a hand full of coils that have...

    I've only seen a hand full of coils that have what seems to be elect. conduit on refrig. lines. They never had any armaflex, I think that was their way or reducing the number of fitting used, played...
  11. Replies
    30
    Views
    3,615

    Never heard of a heat pump that was low on...

    Never heard of a heat pump that was low on charge, so that allowed the compressor to stay running. Now low on charge and not keeping up with the home, but he already stated that the tstat wouldn't...
  12. Replies
    4
    Views
    527

    Checking a temp rise would be one way to check...

    Checking a temp rise would be one way to check and see if it was working. BUT REALLY you need to get on the phone and call a service tech who knows what they are doing with water source heat pumps.:D
  13. If you are really worried about it remove the...

    If you are really worried about it remove the piston and replace it with a txv. Very smart devices!
  14. Replies
    2
    Views
    827

    I agree panning, ductboard, mastic, and silicone...

    I agree panning, ductboard, mastic, and silicone go along way.
  15. Replies
    7
    Views
    990

    If you have a two stage condenser unit doesn't...

    If you have a two stage condenser unit doesn't that require a two stage t stat? Or do they have a jumper like some furnaces???
  16. You need to either one, cough up enough money to...

    You need to either one, cough up enough money to get yourself a new system to cool your other floors. Or get some window a/c's and put them in. Anything else will just make you a hack.
  17. Replies
    63
    Views
    5,241

    Okay so I was laying in bed Thursday night and...

    Okay so I was laying in bed Thursday night and thought about my a/c. What could be wrong, how do I know that its not over charged? So I borrowed a scale and proceeded to pull the charge out. 5lbs 8...
  18. Replies
    63
    Views
    5,241

    Outdoor temp has been low 50's. Suction line...

    Outdoor temp has been low 50's. Suction line frosts up, or I have a leak at one of my txv fittings. was charged. gota go to work.
  19. Replies
    63
    Views
    5,241

    Txv is a 26k34 and is a non bleed type??? and I...

    Txv is a 26k34 and is a non bleed type??? and I also have compressor numbers.

    AW207ET-035
    T6292C 194858 AW5528G
    V200

    Thats all thats stamped on top of the compressor case.
    Been to cold...
  20. Replies
    63
    Views
    5,241

    Your not the only one to say that, but with the...

    Your not the only one to say that, but with the pressures the way they are in the off cycle, I have a hard time believing that a crankcase heater will take care of the issue. Though I could be...
  21. Replies
    63
    Views
    5,241

    I played with the unit once more before dark. I...

    I played with the unit once more before dark. I let it turn on and run for about thirty minutes, it turned off and I decided to crack open both sides of my manifold just a little. They equalized out...
  22. Replies
    63
    Views
    5,241

    Is there a way of testing them? like with multi...

    Is there a way of testing them? like with multi meter?
  23. Replies
    63
    Views
    5,241

    What type of hard start kit should I obtain?

    What type of hard start kit should I obtain?
  24. Replies
    63
    Views
    5,241

    Have the comp. time delay set to 5 min the max my...

    Have the comp. time delay set to 5 min the max my termostat would allow.
  25. Replies
    63
    Views
    5,241

    I don't know alot about hard start kits, I...

    I don't know alot about hard start kits, I installed this one that has the relay and cap all built into one.?? I got it off a retro I was on and installed it onto mine, it said for 4,00btu - 100,000...
  26. Replies
    63
    Views
    5,241

    okay heres all I know about this unit Carrier Mod...

    okay heres all I know about this unit Carrier Mod #38CK030310 Ser#099E07353
    Older unit. When The compressor works, it cools and charges like a dream, im serious.
  27. Replies
    63
    Views
    5,241

    so how would I know what the correct cap would...

    so how would I know what the correct cap would be, I don't see alot on the name plate. contact manufactuer? How?
  28. Replies
    63
    Views
    5,241

    Okay so i went and got the work van today and did...

    Okay so i went and got the work van today and did what you said. I reclaimed all refrigerant( I do have a universal license), took apart txv to check screen, all clean like brand new. Blew nitro...
  29. Replies
    63
    Views
    5,241

    I'm not trying to claim to be the best, I'm new,...

    I'm not trying to claim to be the best, I'm new, but not dumb I know what HCFC's and CFC's do to our environment. I do own a reclaimer and reclaim bottles so whats so wrong with purging with r22 into...
  30. Replies
    63
    Views
    5,241

    Okay the RLA on it is 14.2, when it restarts it...

    Okay the RLA on it is 14.2, when it restarts it pulls low fourtys and cuts out. No I didn't do a vacuum on the system, I only press tested with nitrogen, then purged with 22. yes new evaporator,...
  31. Replies
    63
    Views
    5,241

    I just changed the coil out a week ago and added...

    I just changed the coil out a week ago and added txv, chaged filter when I was down there. Yes the compressor does try to start and it pulls amps and then just stops pulling any current, then in a...
  32. Replies
    63
    Views
    5,241

    Used multi meter to check run cap, it looked new...

    Used multi meter to check run cap, it looked new and check out like it was new off by .5 on herm. Added old start cap, didn't do much.
  33. Replies
    63
    Views
    5,241

    Compressor start up

    Hello, I'm new to this so I'll explain. I am an installer and not into service very much. My own condensing unit at home is acting funny. When i turn the thermostat on to call for cool the first time...
Results 1 to 33 of 92