  1. In the install manual for the Armstrong Heat Pump...

    In the install manual for the Armstrong Heat Pump we just installed it actually showed a diagram using liquid R22 for flushing the existing line set.
  2. Replies
    29
    Views
    4,841

    Oil Burner Basics

    A friend asked me to take a look at their oil burning furnace. I have worked on exactly 2 of these in the past ten years, as our furnaces around here are all LP, Natural, of electric.
    I was...
  3. Replies
    2
    Views
    539

    Gauge accuracy

    What is a good way to check your gauges to know they are reading correctly? I usually check them against each other to make sure they read the same against the same pressure, but how do I know if...
  4. Replies
    24
    Views
    2,122

    I will check back with them tomorrow to see if...

    I will check back with them tomorrow to see if the pilot was causing any problems.

    \
  5. Replies
    24
    Views
    2,122

    The reason I am confused is that there is about...

    The reason I am confused is that there is about 10 foot of uninsulated duct between the evap coil and the furnace and it is not sweating. I thought that would rule out high humidity in the furnace...
  6. Replies
    24
    Views
    2,122

    This is an old natural draft furnace. Is it...

    This is an old natural draft furnace. Is it possible that the hot outdoor air would travel back down the flue and condense on the walls of the cold heat exchanger?
    I did notice the pilot was on...
  7. Replies
    24
    Views
    2,122

    Heat Exchanger sweating

    Went to a house today that complained of water dripping from the furnace. The setup is an older horizontal gas furnace with a evap coil on the return side. The water is dripping from the heat...
  8. Replies
    14
    Views
    2,117

    I see some of the distributors here are now...

    I see some of the distributors here are now paying for recovered R22. Not sure how much, as it depends on purity, but it sure beats having to pay to take it to be recycled.
  9. Replies
    29
    Views
    2,914

    Just curious, how much are your distributors...

    Just curious, how much are your distributors charging for R22?

    I bought a 30# cylinder today for $.
  10. Replies
    11
    Views
    1,308

    As you learn how, pay attention to the...

    As you learn how, pay attention to the "percentage" of the total system charge you are adding. For example, a system that holds 14 pounds will require quite a bit more refrigerant to lower...
  11. Replies
    13
    Views
    2,345

    Same coils here. All EDD's. I would like to see...

    Same coils here. All EDD's. I would like to see at least a little labor compensation. I talked to a couple Tempstar dealers and their distributor was working on the same thing. I would think they...
  12. Replies
    13
    Views
    2,345

    Well, I figured I wasn't the only one having...

    Well, I figured I wasn't the only one having problems. Found another one this past Saturday. This was the start of its third cooling season.
    We haven't gotten anything for a labor compensation,...
  13. Replies
    13
    Views
    2,345

    ICP Evap coil leaks

    We have carried Heil products for about 10 years now and have recently been having a BUNCH of evap coils with leaks. Some are right at the 5year old mark, while others are only on their second...
  14. Replies
    3
    Views
    1,259

    What is the problem? Are neither furnaces...

    What is the problem?
    Are neither furnaces firing?
  15. Replies
    10
    Views
    1,157

    The 16x25 hole in the furnace is big enough, but...

    The 16x25 hole in the furnace is big enough, but the 16x25 filter has a much higher resistance, so the FILTER needs to have a larger area. The above described transition will accomodate that larger...
  16. Replies
    230
    Views
    49,776

    Sticky: Poll: We have sold Heil exclusively for about 10 years...

    We have sold Heil exclusively for about 10 years now.
    Started seeing a lot of evap coil leaks this summer on coils right at the 5 year old mark. Also change an occasional heat exchanger on the...
  17. Replies
    24
    Views
    1,498

    Bringing in fresh air will be a necessity with a...

    Bringing in fresh air will be a necessity with a foamed in house. Everything seals so tightly that the air you breathe, moisture from showers/cooking, vapors from the carpet and construction odors...
  18. Replies
    7
    Views
    1,037

    I would make sure the humidifier is getting good...

    I would make sure the humidifier is getting good run time. If the humidistat is bringing the humidifier on properly, even when the furnace burners are off, the humidity level will eventually rise. ...
  19. Thread: Fuses

    by nehvacman
    Replies
    7
    Views
    689

    If you can find them, some of the older Lennox...

    If you can find them, some of the older Lennox furnaces/air handlers used a clear glass tube fuse. It is different in that it has a couple metal "ears" on the one end that allow it to twist into the...
  20. Replies
    21
    Views
    1,856

    I would agree with the oversized pipe being a...

    I would agree with the oversized pipe being a problem. Depending on how high the vent is running and how much of an offset there is a 5" B-vent is probably plenty, maybe even a 4" would work. Check...
  21. Replies
    16
    Views
    2,769

    I edited my post from before. I realized my...

    I edited my post from before. I realized my infiltration was off. 1800 main floor plus about half of the basement would equal 2809 ft2 X 10 foot (9'ceiling + 1' joist space) =28090 ft3.

    Code...
  22. Replies
    16
    Views
    2,769

    Correct. Ground source heat pump, open loop...

    Correct. Ground source heat pump, open loop (pump and dump) system.

    It looks like I will need 33,000 BTu sensible/6,000 Btu latent, and 46,000 btu heating.

    Does that sound about right for...
  23. Replies
    16
    Views
    2,769

    Correct. 1800 square foot main floor and 1800...

    Correct. 1800 square foot main floor and 1800 square basement. There will not be insulation under the basement floor.

    What other types of wall insulation do you recommend to get better than...
  24. Replies
    16
    Views
    2,769

    Edit. After posting that I realized my...

    Edit. After posting that I realized my Infiltration was a little off. My volume is 2809 which makes my total 2580 BTU. That would bring my sens total to 33,063.
  25. Replies
    16
    Views
    2,769

    Ok. I changed my summer TD to 25 and came up...

    Ok. I changed my summer TD to 25 and came up with about 36,000 sensible. Looks like the Hydron 3-ton will give 39.3 BTU Hi and 29.6 BTU low cooling.

    The main floor square footage is 1873. The...
  26. Replies
    16
    Views
    2,769

    Load Calculation

    I'm pretty new to doing load calculations so I was wondering if anyone would be willing to give me some guidance.

    75deg winter TD, 30deg summer TD near Omaha, NE

    I am working on a 1800 ft2...
  27. Replies
    4
    Views
    2,099

    The cost of the fuel your furnace will burn...

    The cost of the fuel your furnace will burn (natural gas/propane/fuel oil) Vs. the cost of electricity in the area will be the key factor in your decision.

    Here in Neb. heat pumps generally...
  28. I think this furnace will. Give it a try and...

    I think this furnace will.

    Give it a try and let us know.
  29. Replies
    0
    Views
    425

    New Heil 80% and 90% furnaces

    Just wondering what anyone thinks of the new style Heil furnaces. Any pros or cons from the installers?

    We've put in our first of the 90%ers and thought everything went smooth. Did have a...
  30. That "CONT" tap will be powered any time the COOL...

    That "CONT" tap will be powered any time the COOL and HEAT taps are not powered. So basically the fan will run all the time.
Results 1 to 30 of 30