    This needs to posted to everyone! I have had...

    This needs to posted to everyone! I have had several problems with this happening. My OEM supplier has not said anything about any one having this problem. I will be contacting them and asking them...
  2. Replies
    19
    Views
    1,315

    After looking at it again yesterday, I believe it...

    After looking at it again yesterday, I believe it maybe the txv on the condensening unit. While in a/c it worked great. All pressures were great. As soon as switching to heat head pressure shot...
  3. Replies
    19
    Views
    1,315

    Both units are matched. I installed them less...

    Both units are matched. I installed them less than a year ago. Had to replace the txv on the indoor unit this summer.
  4. Replies
    19
    Views
    1,315

    Head pressure on Heating

    Ok Need a little help.

    I have a aire ease 4shp14le136p-6

    When the cooling is on all pressures look good. As soon as I go to heat the pressure shoots straight up to hi pressure and kicks off...
  5. Replies
    12
    Views
    1,680

    Got one driving me crazy

    Ok here it goes... I got one driving me crazy.This is a heatpump. In a dentist office the hyg. area the grils are turning on the heat in the morning then turning on the ac when in the afternoon....
  6. Thread: Pro member

    by swamprunner
    Replies
    4
    Views
    562

    Pro member

    How to become pro member. Not sure how to do it. Thanks I was told I needed one more post.
  7. Replies
    18
    Views
    1,573

    Indoor coil is fine, even cleaned it. Orfice...

    Indoor coil is fine, even cleaned it. Orfice metering device. And crmont you maybe correct. Maybe I just need to spend a little more time over there and look a little deeper and longer. But It is...
  8. Replies
    18
    Views
    1,573

    Dont Have them with me now. I'm sure its not...

    Dont Have them with me now.

    I'm sure its not the unit size or miss match, because these apt. Have been here for several years. Several units in the complex all the same. Even hooked up to the...
  9. Replies
    18
    Views
    1,573

    crmont, Sorry for getting it backwards. I checked...

    crmont, Sorry for getting it backwards. I checked the heat strips with a amprobe. and my volt meter.

    I did get it backwards and will go back and correct it.
  10. Replies
    18
    Views
    1,573

    I am a "pro" not looking for you to fix it. Just...

    I am a "pro" not looking for you to fix it. Just if anyone else has seen these kind of numbers and cant find the problem. I am not DYI. I know you have to post a good bit on here to be a "pro". How...
  11. Replies
    18
    Views
    1,573

    I own a business in South carolina. Tiger Town...

    I own a business in South carolina. Tiger Town Services. Been doing it all my life. Not many will stump me but I cant find a thing wrong. The only other thing is maybe it's not doing it or not...
  12. Replies
    18
    Views
    1,573

    Help with no problem but not cooling

    I have a unit 2 ton a/c heat pump.

    NOT COOLING.... Out side air 90 deg. inside temp 82.

    HI side line temp 92 deg. Hi side pressure 285 psi

    Lo side line temp 55 deg. Lo side pressure 85
    ...
  13. Thanks guys. I think I have a better...

    Thanks guys. I think I have a better understanding of this now. I'm thinking a good application for such device would be a server room, kitchen and such where the weather outside is cool but you...
  14. So what you are saying is keeping the head...

    So what you are saying is keeping the head pressure hi by shutting the fan off you get better efficiency out of the unit. So why should you not do this to all the units.

    Another question is about...
  15. What is the point in that?

    What is the point in that?
  16. Hi pressure switch for cond. fan control

    What is the purpose of putting a hi pressure switch on the cond. fan to turn on and off depending on the hi pressure? I have ran across a few of these.
  17. I called techsupport and he said it was was the...

    I called techsupport and he said it was was the txv in the condensing unit. All I know to do is evacuate the system replace the txv and pull vacumm and recharge. Thanks for your in put.
  18. It was in the heating mode and I am from sc

    It was in the heating mode and I am from sc
  19. how hi was the head pressure and how long would...

    how hi was the head pressure and how long would it run before a problem existed. This unit will only run a few... let's say less than 2 min.
  20. HTRGUY, the fan seems to be running great and the...

    HTRGUY, the fan seems to be running great and the coil is clean.
  21. the low pressure was reading around 52 and the Hi...

    the low pressure was reading around 52 and the Hi side went above 400

    Outside temp was 50 and the inside was around 68

    both units were put in at the same time. around 5 years old.
  22. rhhem problem with Hi head pressure and normal low pressure

    I was looking at a rhhem a/c yesterday and within sec. my head pressure shot up and my lo pressure looked normal. I'm thinking I have a blockage some where. The guy who in stalled this system has...