Search:

Type: Posts; User: Balibe

Page 1 of 12 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    102

    The basic lead/lag that Carrier offers in their...

    The basic lead/lag that Carrier offers in their PICS's are only for the chillers. They don't offer anything in the package units.

    Not sure which PIC's you have in the package units, but you will...
  2. Replies
    1
    Views
    250

    The UCM's should be Comm4 as the CCP is 1997. If...

    The UCM's should be Comm4 as the CCP is 1997. If you have Rover with Comm4 cable you can check. With the relay board in the VariTrac CCP, there should be no comm to the RTU.

    You should be able to...
  3. Replies
    3
    Views
    358

    SketchUp ???? (http://www.sketchup.com/) It is no...

    SketchUp ???? It is no longer owned by Google, Trimble Navigation bought it in 2013 .....
  4. Thread: Trane varitrac

    by Balibe
    Replies
    5
    Views
    338

    Contact your local Trane salesman for the...

    Contact your local Trane salesman for the VariTrac software and cable. All they have for download on their website is update v12sp6.

    If you have Rover, you can access the zone controllers but...
  5. Thread: Trane varitrac

    by Balibe
    Replies
    5
    Views
    338

    Version 6- uses HyperTerminal, beige panel cover...

    Version 6- uses HyperTerminal, beige panel cover with a 2 line lcd display. Version 10+ uses VariTrac software, white panel cover with touch screen.
  6. Thread: MCS CONTROLLS

    by Balibe
    Replies
    1
    Views
    191

    I have integrated a few of these controllers. The...

    I have integrated a few of these controllers. The ones I have dealt with have been programmed specifically for the chiller/scu it controls and not a generic program.

    I would call their tech...
  7. Replies
    40
    Views
    12,986

    FYI ..... Each software requires a separate key...

    FYI ..... Each software requires a separate key to use the software. The ComfortView Key will not work with NSTV and requires additional adapters. The NSTV USB Converter/Key will not work with...
  8. Replies
    3
    Views
    272

    Below are the LED indications, these are for the...

    Below are the LED indications, these are for the BACnet flavor. There does not seem to be a way to reset the card. Verify the 24vac, if someone switched the + and Com to the translator & chiller pic...
  9. Replies
    9
    Views
    406

    I also use comfortsite, the drawing is not there...

    I also use comfortsite, the drawing is not there in the elibrary or under the unit information. From the unit manuals, you have the correct drawing number. There were two units originally ordered,...
  10. Replies
    9
    Views
    406

    Post the serial number of the unit, it will be...

    Post the serial number of the unit, it will be easier to lookup with that versus the drawing number .....
  11. Replies
    4
    Views
    311

    A filter for displayname like *DPR* will show all...

    A filter for displayname like *DPR* will show all points with DPR in the name. Works good if you have several points like DPR_O_1, DPR_O_2, etc.

    There is also the option above the filter to narrow...
  12. Replies
    8
    Views
    526

    I have used the gateway linked below for comm4...

    I have used the gateway linked below for comm4 vav's, it has worked great with no issues for a couple years. I have not used it on anything else but comm4 vav's, but it states it also works with...
  13. I also like to use the SunPostion. If you need it...

    I also like to use the SunPostion. If you need it earlier/later, just add/subtract to the angle. Typically just a couple degrees
  14. Replies
    3
    Views
    423

    To reiterate mcquire07, the controller must be...

    To reiterate mcquire07, the controller must be off the network for the controller to reply it's address when scanned with 0,0. It is rare, but there a few devices that will not reply to 0,0 like...
  15. Replies
    3
    Views
    280

    It is a separate program, you will find it in the...

    It is a separate program, you will find it in the Programs\ComfortView folder with all the other shortcuts ....
  16. Replies
    5
    Views
    646

    You can globally broadcast a single point from a...

    You can globally broadcast a single point from a CC6400 only if the point name is the same in all controllers needing it and the point is writable. The fire shutdown (FSD) in Plinks is a network...
  17. Thread: Ivu server

    by Balibe
    Replies
    4
    Views
    227

    Witt no DHCP server as you are directly...

    Witt no DHCP server as you are directly connected, it will take longer for i-Vu to provide the DHCP to the computer versus a network with a DHCP server.

    Once the i-Vu fully restarts and you have...
  18. Replies
    13
    Views
    678

    Try 85760430 I did an OPM with 17 units on it...

    Try 85760430

    I did an OPM with 17 units on it with a Chipkin FieldServer. This password is in the config file. I also integrated a CSC panel with Chipkin FieldServer and it was the same password....
  19. Replies
    7
    Views
    623

    I have had a similar issue in the past, so make...

    I have had a similar issue in the past, so make sure you verify ..... The older HMI panels may not work with a LCI/BCI. If they are that old you may need to also replace the HMI panel so a LCI/BCI...
  20. Replies
    2
    Views
    309

    In addition to roadgear ..... Typically XIF's...

    In addition to roadgear .....

    Typically XIF's are used for LON integration. The AX platform will use the XIF to create a LNML, which will map out the points based on the XIF with point details...
  21. Replies
    4
    Views
    456

    We just had a similar issue with a BCI-R shipped...

    We just had a similar issue with a BCI-R shipped in a unit from Trane.

    Is this a newer unit with the 3 rotary dials for the address? What is the baud rate of your network? Trane ships them at...
  22. Replies
    12
    Views
    803

    If a program is created in Snap or edited by Snap...

    If a program is created in Snap or edited by Snap and saved, it cannot be opened with EquipmentBuilder. It can only be opened/edited with Snap.
  23. Replies
    16
    Views
    828

    I have never seen this error before either. Have...

    I have never seen this error before either. Have you sent the error thru your local support channels?

    The tech tools cable did not change. You cable sounds good as you find and start uploading.
    ...
  24. Replies
    16
    Views
    828

    If these are new controllers I would agree you...

    If these are new controllers I would agree you need v6.0. It would be a good idea to load the August Cumulative Patches into FieldAssistant before you upload. They have made driver changes since the...
  25. Replies
    1
    Views
    355

    Do you have the recent patches installed? The...

    Do you have the recent patches installed? The cumulative patch releases for i-Vu also need to be applied to Field Assistant, which will also patch Snap & Equipment Builder if installed.

    Start...
  26. Not sure if it is wise to remove the CCN...

    Not sure if it is wise to remove the CCN ComfortLink Controls and replace with another controller.

    Carrier sells an Open UPC that will convert the CCN controls to BACnet MS/TP. Not sure if you can...
  27. Version 6 and down is accessed with...

    Version 6 and down is accessed with Hyper-Terminal. Version 10 and up is accessed with Trane's Tracker software.
  28. Replies
    6
    Views
    663

    You can find older versions here .......

    You can find older versions here .... http://www.oracle.com/technetwork/java/javase/downloads/java-archive-downloads-javase7-521261.html

    There are version all the way back to v7u1 on this page,...
  29. Thread: Trane VSEE vav

    by Balibe
    Replies
    5
    Views
    524

    +1 .... don't reuse the existing assembly. We...

    +1 .... don't reuse the existing assembly.

    We retrofit a lot of these, they are very common in my area. We are in the process of doing two floors with 60 of these per floor.

    We pull the...
  30. Replies
    3
    Views
    419

    +1 Rover will not configure a BCU. You will...

    +1

    Rover will not configure a BCU. You will not be able to access the BCU with a display by just adding one. They are configured, setup and downloaded to a BCU with Summit.
  31. Replies
    20
    Views
    1,304

    Check the updates they gave you, the USB...

    Check the updates they gave you, the USB communications update is a driver not included in cumulative update released in August. The driver file should have been “drv_ivuexp_6-00a-023.driver” which...
  32. Replies
    20
    Views
    1,304

    What version? If v6.0 Standard with the USB...

    What version? If v6.0 Standard with the USB adapter, there is a new driver released in March that resolves communications issues. Controls Bulletin #IOB14003A references the update.
  33. It is a 26.8mb zipped file, if you have access it...

    It is a 26.8mb zipped file, if you have access it is downloadable from hvacpartners.com.
  34. Replies
    1
    Views
    232

    You have mail .......

    You have mail .......
  35. Replies
    4
    Views
    390

    With CCN you broadcast, with Open you will need...

    With CCN you broadcast, with Open you will need to read. Open will broadcast when a Linkage is setup.

    You want System Outdoor Air Temperature, which is found under Properties\Network Points....
  36. Replies
    32
    Views
    2,028

    Your FXWorkbench should be licensed for...

    Your FXWorkbench should be licensed for everything [all drivers/protocols]. I have never had an issue hooking up directly to lon networks with FXWorkbench and a USB Lon adapter.
  37. Replies
    35
    Views
    3,394

    +1 Getting old seeing this guy resurrecting...

    +1

    Getting old seeing this guy resurrecting all these threads that are over a year old .... each with a PDF attachment??
  38. Thread: Orion Controls

    by Balibe
    Replies
    1
    Views
    320

    http://orioncontrols.wattmaster.com/literature-new...

    http://orioncontrols.wattmaster.com/literature-new.html
  39. Replies
    7
    Views
    446

    Johnson Controls also has a wireless system that...

    Johnson Controls also has a wireless system that works well.
  40. I have one jobsite with this same issue, works...

    I have one jobsite with this same issue, works fine on my Verizon hot spot and all hardwired connections but will not connect with the customers AT&T hot spot. I always thought the issue was with...
  41. Replies
    10
    Views
    760

    I did some research with a v4.2 and v6.0. I will...

    I did some research with a v4.2 and v6.0. I will try to make this easy to understand, but there is no formula/logic (decoder ring) that will easily get you the info you want. You will need to have...
  42. Replies
    10
    Views
    760

    So you are looking at the points on the IP side...

    So you are looking at the points on the IP side of the Router and trying to figure out which VAV the BACnet points are assigned to?

    If so I can look at one of my sites on the IP side to see if...
  43. Replies
    10
    Views
    760

    You wil not see the address under network points...

    You wil not see the address under network points with a factory control program. All point address's under the network points tab will be ccn:\\link\point_info, the "link" can be changed to the...
  44. Replies
    3
    Views
    432

    Snap has a programming block for lead/lag under...

    Snap has a programming block for lead/lag under Misc\Proof. It does rotation based on runtime and failsafe if the lead does not proof. It will also generate fail & hand alarms if needed. If you have...
  45. Replies
    6
    Views
    415

    The 4th digit of the model number is the...

    The 4th digit of the model number is the Development Sequence. F = Sixth & G = Seventh. The breakdown is in one of the PDF's I emailed you.
  46. Replies
    6
    Views
    415

    Model Number: SXHFC6040M56C79D6001BELRT8PK Job...

    Model Number: SXHFC6040M56C79D6001BELRT8PK
    Job Name: Concord Park
    Shipped: 10-16-1997

    The original model number breakdown does not show an LCI. The unit documents only go back so far. I found...
  47. Replies
    6
    Views
    415

    From my understanding is the older panels do not...

    From my understanding is the older panels do not support the LCI. I don't know when the change occurs. Not 100% but think you can replace the panel with a newer version that works with an LCI. That...
  48. Replies
    11
    Views
    923

    When you right click the VAV graphic and edit...

    When you right click the VAV graphic and edit UCM, you are in the UCM. You can use Summit to modify the settings. They are live settings in the UCM versus a local saved database.
  49. Replies
    11
    Views
    923

    UCM address of 1 on the dipswitch will be VAV...

    UCM address of 1 on the dipswitch will be VAV address 65 in Tracer. Address 2 will be 66, etc .....

    There should be a sticker inside one of the VAV's showing the dipswitch address scheme ....
  50. Thread: CCN Issue

    by Balibe
    Replies
    10
    Views
    609

    How are you changing the broadcast acknowledger...

    How are you changing the broadcast acknowledger [BA]?

    These are Gen2 VVT?

    Older Gen2 VVT will not talk CCN without a Gateway. Only Gen3 and up will talk CCN.

    If they have a display and 4...
Results 1 to 50 of 553
Page 1 of 12 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event