  1. Replies
    6
    Views
    616

    We have used the media you ask about, like 270...

    We have used the media you ask about, like 270 indicated if you don't have enough cond fan power you can do more harm than good.

    I have found those thin sponge filters to be worthless if there is...
  2. Replies
    23
    Views
    2,121

    If building looses power expect to looses lots of...

    If building looses power expect to looses lots of co2, and expect to spend lots of time recharging it!

    They seem to use more energy than a conventional rack system, at least in our applications.
    ...
  3. All that work for nothing

    All that work for nothing
  4. Replies
    7
    Views
    471

    No slime, a kind of an aqua green. We don't...

    No slime, a kind of an aqua green.

    We don't use any dye (at least that's what my guys tell me Ha!)

    I think I'm gonna hunt that dye thing, but I looked over past service history today and the...
  5. Replies
    7
    Views
    471

    Drier core green

    Pulled out drier cores (liquid line) the other day that were green.

    Low temp, scotch foursome rack, 404a, POE lubricant, oil clean.

    I'm guessing copper sulfate what you all think?
  6. Yep, I have my last drum of r12 to an aviation...

    Yep, I have my last drum of r12 to an aviation mechanic.

    Don't tell your wife.
  7. I would check those line sizes for proper minimum...

    I would check those line sizes for proper minimum velocity.

    As Mike says how about those t-stat and solenoid valve per coil, I'm not sure that would be a good thing.

    I have used Zerol 150 to...
  8. Replies
    17
    Views
    1,291

    I have seen screens sucked in like an accordion....

    I have seen screens sucked in like an accordion.
    Like JP lots of powdered aluminum and iron powder, and like rock says since POE lots of soapy gook with the other mixed in.

    I still say need to...
  9. Replies
    19
    Views
    1,574

    Actually the motor and control board are not...

    Actually the motor and control board are not synchronized are they, doesn't the board drive the motor a certain number of steps regardless of where the motor is positioned?

    I'm thinking the motor...
  10. Replies
    5
    Views
    630

    Chops that was a great video I gain from your...

    Chops that was a great video

    I gain from your hours of research

    Thanks
  11. Replies
    5
    Views
    630

    Brian I do keep them laughing, but it's not my...

    Brian
    I do keep them laughing, but it's not my jokes it's the stupid stuff I do.
    I do like the FP they seemed a little hard to read in the sun (but I'm an old man and can hardly see anything)
    ...
  12. Replies
    17
    Views
    1,291

    Drill bit, I've been looking for that! Your...

    Drill bit, I've been looking for that!

    Your right probably all kind of scrambled parts in there, and it is probably plugging the oil intake screen.

    I have never had the "swap two legs" work...
  13. Replies
    17
    Views
    1,291

    I think you miss my point, if it throws a rod you...

    I think you miss my point, if it throws a rod you will blow oil out of the crank oil galley. Then you will have very low net oil pressure

    We don't have all the data but the suction looks high to...
  14. Replies
    5
    Views
    630

    Electronic manifold

    I'm going to get a set of electronic manifold, with micron gauge.

    I've had the Fieldpiece I liked them.

    Want to gets some ideas
  15. Replies
    17
    Views
    1,291

    How about the amp draw? Looks like lo head and...

    How about the amp draw? Looks like lo head and hi suction, is there vibration, if it's thrown a rod you can have very low net oil pressure.

    Refrigerant charge should not affect net oil pressure
  16. Replies
    38
    Views
    2,488

    H-10 worth the extra money and trouble, a little...

    H-10 worth the extra money and trouble, a little harder to use, much mire accurate when properly used, just my opinion
  17. Replies
    19
    Views
    1,574

    Most of my experience is with the Sporlan CDS...

    Most of my experience is with the Sporlan CDS valves

    I have found that when you have to reset the control board (or power it off) often that you generally end up replacing the operator (motor)....
  18. Replies
    44
    Views
    4,044

    Do you think most top techs are more interested...

    Do you think most top techs are more interested in real world training than an actual certification?

    I know I like the half and one day seminars that are about stuff I work on like supermarket...
  19. Replies
    56
    Views
    3,291

    Well it's 2013 and RSES is still here, I don't...

    Well it's 2013 and RSES is still here, I don't say that in a boasting way recent years have been tough.

    We do need to keep and grow our membership in a big way. We really need the support of the...
  20. Does anybody know of a dependable portable...

    Does anybody know of a dependable portable detector that read direct ppm?
  21. Replies
    27
    Views
    5,394

    Wouldn't the bulbs actually be connected parallel...

    Wouldn't the bulbs actually be connected parallel to the windings?
  22. Thread: Amp meter

    by steve wright
    Replies
    57
    Views
    6,331

    Thanks to all you for your input it is very...

    Thanks to all you for your input it is very helpful.

    I'm going to try the Fluke 376 or 902, I currently have a Fluke 30 so I'm comfortable with it.

    Thank so much
  23. Replies
    4
    Views
    1,312

    Removed sorry no *

    Removed sorry no *
  24. Replies
    10
    Views
    2,351

    Gary makes an important point you are using cfm...

    Gary makes an important point you are using cfm you have to look at mass flow in #/min
  25. Thread: Amp meter

    by steve wright
    Replies
    57
    Views
    6,331

    Strkout I saw where it has the hold but does...

    Strkout

    I saw where it has the hold but does it hold max hold like when checking peak LRA?
  26. Replies
    17
    Views
    2,167

    Hey I'm at 41 years and the only thing I know for...

    Hey I'm at 41 years and the only thing I know for sure is the more I learn the more there is to learn.

    In the field there are many things like instrument error that can make not add up.

    :grin2:...
  27. Thread: Amp meter

    by steve wright
    Replies
    57
    Views
    6,331

    Amp meter

    What are some good meters that will lock in peak amps?
  28. Replies
    17
    Views
    2,167

    It does for resistive loads the CCH is resistive....

    It does for resistive loads the CCH is resistive.

    You are right that it will not work with capacitive or inductive loads.
  29. Replies
    43
    Views
    6,204

    Better to eat crow with us than the customer! ...

    Better to eat crow with us than the customer! They make you eat the feathers too.

    Your doing what you should staying with the problem, I bet they will understand
  30. Replies
    30
    Views
    3,702

    Yea I agree. Sometimes you can add a little AB...

    Yea I agree.

    Sometimes you can add a little AB lubricant and it will help bring oil back
  31. Replies
    17
    Views
    2,167

    If you google copeland AE 4-1312 then go the list...

    If you google copeland AE 4-1312 then go the list of CCH for described scroll comp.

    They are heater wire not solid state in this range size.

    You might be waiting a while for them to get back. ...
  32. Thread: AB Oil

    by steve wright
    Replies
    10
    Views
    1,815

    I don't know about Copeland but Genetron R422C...

    I don't know about Copeland but Genetron R422C says it will work with MO AB or POE lubricants, hence no oil change.

    My experience tells me that the AB will have fewer oil return problems in your...
  33. Replies
    17
    Views
    2,167

    Most of those heaters I've seen about 70 watts...

    Most of those heaters I've seen about 70 watts (with comp # we can find out exactly) with 230V that wold be about 0.3 amps. Hard to read.

    To get more accurate reading you can loop wire five times...
  34. Replies
    15
    Views
    2,333

    Are you saying you have less superheat after the...

    Are you saying you have less superheat after the heat exchanger? Colder at the outlet of heat exchanger than the inlet?
  35. Replies
    30
    Views
    3,702

    If that comp had mineral oil and you put r401...

    If that comp had mineral oil and you put r401 without changing to alky oil I bet comp seizing up.

    As a last ditch effort you might try some Supco 88, sometimes it works sometimes not.
  36. Replies
    15
    Views
    2,210

    While you have that valve plate off you want to...

    While you have that valve plate off you want to check piston and bore for wear and damage, if it is air cooled (no oil pump) you will need to check the wrist pin too.

    When you drop a suction valve...
  37. Replies
    47
    Views
    7,847

    FYI to all regarding CM Exam, Jayson Goff will be...

    FYI to all regarding CM Exam, Jayson Goff will be presenting a CM Prep Session at the RSES Conference next week (11-14-2012 to 11-16-2012).

    There will be a lot of other educational stuff going on...
  38. Replies
    24
    Views
    3,570

    Installing a systematic leak detection system...

    Installing a systematic leak detection system will help and i guarantee you it will pay for its self. But like jp says you gotta fix the leaks.

    If the store is r22 and has a high concentration...
  39. Replies
    38
    Views
    3,640

    now your talking Mike

    now your talking Mike
  40. Replies
    38
    Views
    3,640

    That is a good point if you make everything up...

    That is a good point if you make everything up ahead of time you could prob change real quick.

    Most of those nozzles are removable, i wont say easily though, if it is corroded in it could be tough.
  41. Replies
    38
    Views
    3,640

    Mikeacman that was meant for Mrak you all were...

    Mikeacman that was meant for Mrak you all were talking about all kind of misspelled stuff your post 14 I think, I sure don't cast stones cause I'm the worst.

    I did think it was interesting how our...
  42. Replies
    38
    Views
    3,640

    Another point is if system was charged during the...

    Another point is if system was charged during the summer they may not have put enough in to flood the condenser during lower ambients when the OROA (or LAV) valve comes into play it will loose liquid...
  43. Replies
    38
    Views
    3,640

    Are we still talking about Mrak's unit? I'm...

    Are we still talking about Mrak's unit? I'm confused but that dont take much.
  44. Replies
    38
    Views
    3,640

    Does that unit have hot gas bypass

    Does that unit have hot gas bypass
  45. Replies
    38
    Views
    3,640

    As josey Whales would "say I recon so"

    As josey Whales would "say I recon so"
  46. Replies
    38
    Views
    3,640

    Doing some amazing things I cdnuolt...

    Doing some amazing things




    I cdnuolt blveiee taht I cluod aulaclty uesdnatnrd waht I was rdanieg. The phaonmneal pweor of the hmuan mnid aoccdrnig to rscheearch at Cmabrigde Uinervtisy, it...
  47. Replies
    21
    Views
    4,537

    Believe it or not Trane Application Guide...

    Believe it or not Trane Application Guide SS-APG001-EN says "to slope 1/4" to 1" per 10 feet of run toward the evaporator"

    We were installing some 80 ton splits about 15 years ago when i got this....
  48. Replies
    8
    Views
    1,488

    I would consider using two condensing units so...

    I would consider using two condensing units so you would have some redundancy
  49. It really warms as it collects moisture. I'm not...

    It really warms as it collects moisture. I'm not talking about reactivation. It is transient but you can sense it when compared to entering liquid temp going into the drier. It does not affect...
  50. Driers warm as they pick up moisture, I think you...

    Driers warm as they pick up moisture, I think you defiantly have a leak, with POE oil and moisture you are going to be making acid big time.

    I didn't see where you had changed the drier maybe I...
Results 1 to 50 of 167
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event