Search:

Type: Posts; User: shavedneon

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    38
    Views
    1,634

    Just like every other tool, it's always better to...

    Just like every other tool, it's always better to have it, (or two, or three), and not need it....
  2. Thanks guys, as always great information. I am...

    Thanks guys, as always great information. I am completely unfamiliar with chimneys and liners as we have VERY few homes with chimneys here, very few basements. Only seen a few boilers, I may try...
  3. Thanks, I've shown that to the inspectors and...

    Thanks, I've shown that to the inspectors and they go back to the venting tables and want it shown there. I haven't been able to find the corrugated piping venting tables, if they exist. I think they...
  4. We can't get the inspector to approve the...

    We can't get the inspector to approve the flexible connector unless it's a dedicated flue, where did you get the chart to get it approved in this case (common vent)? Tried it about 3 times...
  5. Replies
    15
    Views
    2,386

    Reminds me of one that we did at my last company,...

    Reminds me of one that we did at my last company, it was cross the street from town hall. They made us move it 20' cross the roof, and rooftop duct to the penetrations so that it wasn't visible from...
  6. Replies
    11
    Views
    1,339

    Enough fur to start my own cat

    Call for water on floor/ condensate problem, completely impacted coil. Of course they claim to change the filter monthly.505211505221
  7. Replies
    35
    Views
    5,619

    I've gone thru 3 of these stupid hoses just this...

    I've gone thru 3 of these stupid hoses just this season. All three have split the inner hose somewhere in the middle. The warranty has covered each of them, so it's not that bad, I love the...
  8. Thread: Got shocked

    by shavedneon
    Replies
    48
    Views
    3,493

    I've probably opened thousands of disconnects...

    I've probably opened thousands of disconnects without ever thinking twice, it's gotta be a once in a lifetime thing( at least I hope). Has anyone EVER seen this happen or heard of the cover to the...
  9. Thread: Got shocked

    by shavedneon
    Replies
    48
    Views
    3,493

    502801 I own the breaker/ disco now, went back...

    502801
    I own the breaker/ disco now, went back and replaced with a fused disconnect, swapped out faulty 90amp in the panel, changed the compressor and cleaned the coil the following day. Picture of...
  10. Thread: Got shocked

    by shavedneon
    Replies
    48
    Views
    3,493

    Ok guys, I'm still here. It's our very busy...

    Ok guys, I'm still here. It's our very busy season here in the desert. I made a video for my wife to see right after it happened, it's very unprofessional and not edited at all but maybe you can see...
  11. Thread: Got shocked

    by shavedneon
    Replies
    48
    Views
    3,493

    Got shocked

    501401501411
    Just opened the disconnect on the roof and tried to lock it open using both hands, the door hit the aluminum four wire and white sparks all over, 3rd degree burns on both hands and thru...
  12. I've always wanted a half mute button on tv and...

    I've always wanted a half mute button on tv and stereos, and even car radio, sometimes you don't want to completely mute it.
  13. Replies
    11
    Views
    639

    Thanks for your responses. I guess my opinion is...

    Thanks for your responses. I guess my opinion is kind of like how some people feel about goodman, where it's not exclusive or that anyone can get them. Like someone doing side work or something. I...
  14. Replies
    11
    Views
    639

    What POS/ CC systems does everyone use?

    My brother in law is an HVAC contractor, talking with him the other day, he's using the square reader. My opinion is that square is more for guys without licenses and not very professional. He says...
  15. Thread: AEROSEAL

    by shavedneon
    Replies
    35
    Views
    2,152

    I set up the aeroseal operation at my last...

    I set up the aeroseal operation at my last company, had great results. We sealed over 150 houses in the first year of sealing. The worst house I sealed was 625 cfm of leakage, sealed it down to 3...
  16. Unit is an 04 Trane 14 SEER 5ton packages...

    Unit is an 04 Trane 14 SEER 5ton packages heatpump.

    I've never heard of any constant fan rebate. That's just bizarre. It was pulling like 1.3 amps or somewhere around there, kinda makes sense, I...
  17. Same thing here, it's been fan on fan off without...

    Same thing here, it's been fan on fan off without a call for a few years, it stopped on its own last year sometime. When it came back it was full speed, not ramping up and down. Another tech threw a...
  18. Just had the exact same problem, started with the...

    Just had the exact same problem, started with the board, just replaced the module, fingers crossed. What did you end up doing to fix yours?
  19. Replies
    0
    Views
    292

    BNIB REFCO Vacuum pump

    Brand new in box, 5CFM vacuum pump by REFCO, 115v, 2 stage, designed specifically for HVACR service, 1/2 HP, 25 microns, 1/4" and 3/8" flares
    Model number ECO-5
    Asking $200 OBO
    Shipped from zip...
  20. Replies
    8
    Views
    2,656

    Try to seal this duct !!

    At a home to perform an aeroseal, as I walked in I see can lights in the hallway ceiling (where the duct runs). The guys he hired to install the can lights just hacked into the ductwork. He will now...
  21. Replies
    3
    Views
    692

    Try to seal this duct

    At a home to perform an aeroseal, as I walked in I saw can lights in the hallway ceiling (where the duct runs). The guys he hired to install the lights just hacked into the duct.338701338711338721
  22. roof top flex duct with PVC support structure

    I took this picture a few years ago, I need to go back by and see what it looks like now. Can you believe this crap?
  23. Replies
    13
    Views
    1,886

    Flex duct won't last a year outside here. The...

    Flex duct won't last a year outside here. The mylar jacket is quickly disinegrated. Legally the flex can't be installed outside, I've seen it fill with water on new construction before the roofing is...
  24. Replies
    16
    Views
    2,347

    of course it's a goodman

    DeltaT, The whole thing was a good laugh, the maint. guy was getting pist at me for taking pictures, I asked who did THIS, he finally fessed up.
    heres a couple more pics of that service port.
  25. Replies
    13
    Views
    1,886

    Mark, Basically, the cooler sat on the angle iron...

    Mark, Basically, the cooler sat on the angle iron stand in the corner of the picture, flex duct connected to swamp cooler duct that fed into the soffit. Up near the eaves, very close to the roof.
Results 1 to 25 of 86
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event