    Called 3 suppliers today and all said the same...

    Called 3 suppliers today and all said the same thing:

    5 jugs max, without corporate approval (EPA trying to discourage hoarders) and the prices have gone way up.
    Guess it'll make replacement...
  2. Replies
    3
    Views
    685

    New Carrier System

    I just changed my 58MVB out to the 59MN7 furnace with the 25VNA048 (personal use prices from Carrier are nice). Have yet to hook up the heat pump since the electrical circuit is a touch small. I...
  3. Replies
    22
    Views
    1,637

    Do you have a return grill in your ceiling...

    Do you have a return grill in your ceiling somewhere? That duct should be connected to the grill somehow. And yes, measure the incoming air at the grill and right before the furnace. I've seen...
  4. Replies
    5
    Views
    697

    And food, and gas and everything else :/ Metal...

    And food, and gas and everything else :/

    Metal prices are going through the roof! The only good thing is it's making the recycling more profitable. Reclaiming and paying for recycling of refer...
  5. Replies
    3
    Views
    763

    Discharge shouldn't be 40 degrees at the...

    Discharge shouldn't be 40 degrees at the register. Unless you're wanting to freeze that coil. Mid to upper 50's maybe.
  6. Discharge of 105 degrees is what I was told the...

    Discharge of 105 degrees is what I was told the unit could maintain (in the comfort setting I'd assume). And at 22 degrees you should get about 100% capacity since it's near or at 100% capacity of...
  7. Replies
    3
    Views
    453

    Also if you are manually turning the thermostat...

    Also if you are manually turning the thermostat down 5 or 6 degrees when its 90 degrees, it's going to take the air conditioner longer to cool the house down than when it's 80 outside and your house...
  8. Replies
    16
    Views
    1,286

    If he knocked it off, it wouldn't be a drier. ...

    If he knocked it off, it wouldn't be a drier. Maybe a high or low pressure switch? Or was it a snap on type device? Like for temperature.
  9. Replies
    9
    Views
    2,527

    Also 5-ton units are not as efficient as the...

    Also 5-ton units are not as efficient as the smaller units due to the physical size. They could be but then they would be 5' tall and 4' square.

    Carriers new 25VNA has the same cabinet size for...
  10. Thread: carrier

    by bartdude
    Replies
    21
    Views
    1,427

    Type in FA4ANF in Google and you'll find the...

    Type in FA4ANF in Google and you'll find the documents online.
  11. Replies
    35
    Views
    5,125

    New Infinity Stat will be needed to show all the...

    New Infinity Stat will be needed to show all the new info.

    Article on it: http://www.achrnews.com/Articles/Feature_Article/BNP_GUID_9-5-2006_A_10000000000001016449
  12. Replies
    35
    Views
    5,125

    Some ratings are out on AHRIdirectory.org Type...

    Some ratings are out on AHRIdirectory.org
    Type in 25VNA for the outdoor unit and FE4 for the indoor unit (that or leave them blank and type in Min HSPF = 12 and search).

    The heating capacities at...
  13. I saw some limited info on it last month. Can't...

    I saw some limited info on it last month. Can't recall the compressor manufacturer but they said it was one Carrier uses a lot.
    Inverter control modulating down to 40% capacity (30% with Infinity...
  14. Replies
    7
    Views
    547

    Carrier still makes them but we've only installed...

    Carrier still makes them but we've only installed maybe 1/year and mainly in commercial jobs. But have done some in residential where a vertical discharge wouldn't work.
  15. Replies
    9
    Views
    857

    A lot of suppliers sell these so there may be...

    A lot of suppliers sell these so there may be stock around for first company units.
  16. There should be some paperwork in the box showing...

    There should be some paperwork in the box showing what orifices to use at what elevation etc. That or in the original installation manual for the furnace I believe it shows it might show it there...
  17. Replies
    20
    Views
    2,269

    Might look into a different coil, but the higher...

    Might look into a different coil, but the higher efficiency A/C's require more coil surface area which get squeezed into small cabinets and up the restriction. Some of the coils cabinets I've seen...
  18. Replies
    42
    Views
    3,678

    Carrier serial #'s: 7 digits = pre 1969 (so it...

    Carrier serial #'s:

    7 digits = pre 1969 (so it looks to be a 1963?).
    1 letter (A-L, A=Jan, B=Feb...)+ 6 digits = 1970 - 1979
    1 letter (M-Z, M=Jan...) + 6 digits = first part of the 80's
    Much...
  19. Replies
    8
    Views
    3,838

    The HPA6 has a full wrap around coil, whereas the...

    The HPA6 has a full wrap around coil, whereas the HNA6 is 3 sided. The greater coil area is helping the efficiencies, but also making it more $$. But they do get some great numbers on those units...
  20. Replies
    40
    Views
    2,496

    This thread sure got hijacked :D Might look...

    This thread sure got hijacked :D

    Might look into the HPA6 as well. Some higher efficiency's as well as 2 stage. Actually gets some better efficiencies than the Infinity due to its larger coil...
  21. Yes, I used your link ;) I've always had...

    Yes, I used your link ;)

    I've always had trouble with that site but somehow it worked this time.
  22. ARI says: Broan, Frigidaire, Maytag, Nordyne,...

    ARI says:
    Broan, Frigidaire, Maytag, Nordyne, Nutone, Tappan, Westinghouse (all the same).
  23. Replies
    17
    Views
    2,609

    MIght also look at the new 25HPA6 2 speed unit. ...

    MIght also look at the new 25HPA6 2 speed unit. Getting some really nice performance with that unit!
  24. Replies
    2
    Views
    703

    Need to install per the Goodman installation...

    Need to install per the Goodman installation manual,
  25. Replies
    12
    Views
    826

    Had a customer order one of these online. He had...

    Had a customer order one of these online. He had us install it early this year and he hasn't had any complaints. He researched for about a month. Had to install additional vents in the attic to...
Results 1 to 25 of 169