  1. Sometimes the contracts are bid to be losers so...

    Sometimes the contracts are bid to be losers so that the real money comes in with pull-through work.
  2. That is not preventative maintenance...but it...

    That is not preventative maintenance...but it does seem like a waste of money.
  3. Replies
    78
    Views
    3,460

    When I use a watt meter, I use a 3 phase watt...

    When I use a watt meter, I use a 3 phase watt meter which will do single phase too so no problem there.
  4. Replies
    78
    Views
    3,460

    You have forgotten to multiply by the square root...

    You have forgotten to multiply by the square root of the number of phases.

    W = V * I * PF * SQRT (#)

    For a single phase system, the square root of 1 is 1. For 3 phase systems, the square root...
  5. Replies
    78
    Views
    3,460

    if we are still talking about the CRJ3-0300-TF5...

    if we are still talking about the CRJ3-0300-TF5 on R22 then

    at 200 psig condensing pressure and 45 psig evaporating pressure with 10F Subcooling and 20F Suction Superheat, then you get:

    26,500...
  6. Replies
    78
    Views
    3,460

    That is not watts...that's VA. There is a big...

    That is not watts...that's VA. There is a big difference.

    Watts is a smaller number than VA.
  7. Replies
    71
    Views
    19,515

    It isn't that we don't want chemical-free...

    It isn't that we don't want chemical-free systems...i REALLY want this "technology concept" to work....it is just that I have to deal-with and clean-up after it doesn't.
  8. Replies
    12
    Views
    395

    Find out what pump you need for job. Plot your...

    Find out what pump you need for job. Plot your system curve on that chart and compare that system to the minimum flow rate of your boilers or chillers or whatever equipment you have in the loop....
  9. Replies
    5
    Views
    339

    Nope. Do not open the secondary valves until the...

    Nope. Do not open the secondary valves until the primary system is offline and it's valves are closed.
  10. Replies
    1
    Views
    205

    Bad wiring harness connection?

    Bad wiring harness connection?
  11. Replies
    12
    Views
    395

    A single, 3-way valve with an auto flow valve in...

    A single, 3-way valve with an auto flow valve in the bypass line sized for minimum flow rate as far from the pump as possible and you are done. Easy. Easy to size. Easy to maintain. Easy to setup.
  12. Replies
    5
    Views
    339

    I worked on a system that was similar to this but...

    I worked on a system that was similar to this but it was 3 separate condensing units with 3 different evaporators and a 4th condensing unit as a back up. The 4th condensing unit was piped so that it...
  13. Replies
    19
    Views
    2,973

    "Power Consumption" is very different than amp...

    "Power Consumption" is very different than amp draw....while the 2 are related they are not the same.
  14. Replies
    40
    Views
    1,402

    sometimes you have to dig hard to find the root...

    sometimes you have to dig hard to find the root cause...great job!
  15. Replies
    19
    Views
    2,973

    Does it come in a garlic oil or peanut oil...

    Does it come in a garlic oil or peanut oil variety? I personally like cooking with them instead.
  16. Replies
    40
    Views
    1,402

    Your coils have some kinks it them. I think you...

    Your coils have some kinks it them. I think you have some restrictions.
  17. Replies
    40
    Views
    1,402

    We ain't all that serious sometimes!

    We ain't all that serious sometimes!
  18. Replies
    65
    Views
    2,075

    Are you sure that it is R22? Lots of things would...

    Are you sure that it is R22? Lots of things would have to fail/get bypassed to get that kind of head pressure. R410a would most likely be the refrigerant.
  19. Replies
    11
    Views
    484

    What are going to bench test it for? No matter...

    What are going to bench test it for? No matter what "speed" you select, it is going to run close to 1800 RPM with no load but the rotor.
  20. Replies
    16
    Views
    730

    Local 0.5

    Local 0.5
  21. Replies
    16
    Views
    730

    Air Gnome got into the duct and is eating all of...

    Air Gnome got into the duct and is eating all of the air.

    You have an obvious restriction of some kind. Going to have to get up there to check. Could be an engineering error too.
  22. Replies
    34
    Views
    1,611

    I suppose in some areas, a crane is more...

    I suppose in some areas, a crane is more expensive and of course it does depend on height/reach required.
  23. Replies
    34
    Views
    1,611

    I like the catapult idea! Sometimes a crane is...

    I like the catapult idea! Sometimes a crane is much cheaper. It doesn't sound like it would be but sometimes it really is versus a couple extra guys and all of the standing around time that seems to...
  24. Something else to keep on mind is whether the...

    Something else to keep on mind is whether the TXV's bulbs are on the correct coil. Since the TXV equalizer lines are so close together and essentially at the same suction pressure, they don't really...
  25. Shut off the HGBP valve to setup the TXV's....it...

    Shut off the HGBP valve to setup the TXV's....it can be done but it just complicates things. The biggest problem that I see with dual valve setups and HGBP is the lack of check valves in the HGBP...