Search:

Type: Posts; User: joe2003

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Thread: overflow

    by joe2003
    Replies
    7
    Views
    830

    overflow

    We have had 3 geo systems that after running about 9 months to 1 year on a pressureless system all of a sudden overflow fluid from the QT center, we have flushed them with the flush cart until all...
  2. Replies
    5
    Views
    771

    Thank You cmajerus

    Thank You cmajerus
  3. Thread: oil

    by joe2003
    Replies
    0
    Views
    445

    oil

    Worked on old quaker oil stove today and oil regulator not working properly. Model #HB4308D60. S#37914. Is there a company out there that still sells this type of equipment. I want to replace this...
  4. Thread: Leak

    by joe2003
    Replies
    5
    Views
    717

    If it would stop a leak why would one not like...

    If it would stop a leak why would one not like it? Is it harmful for compressor?
  5. Thread: Leak

    by joe2003
    Replies
    5
    Views
    717

    I have a customer with a refrigerant leak in his...

    I have a customer with a refrigerant leak in his lineset which is in a wall which goes up 3 stories to an evaporator in the attic. I did an isolation test on system to determine that leak was there....
  6. Thread: overloads

    by joe2003
    Replies
    3
    Views
    531

    What are the reasons for a compressors internal...

    What are the reasons for a compressors internal overload to open?
  7. Thread: question

    by joe2003
    Replies
    11
    Views
    1,011

    sublimation was the term i was looking for. Thank...

    sublimation was the term i was looking for. Thank you
  8. Thread: question

    by joe2003
    Replies
    11
    Views
    1,011

    very funny everyone, but i still haven't seen an...

    very funny everyone, but i still haven't seen an answer. LOL
  9. Thread: question

    by joe2003
    Replies
    11
    Views
    1,011

    if one were to change 32 degree ice to a vapor,...

    if one were to change 32 degree ice to a vapor, what is the term used to describe this?
  10. Thread: oil

    by joe2003
    Replies
    4
    Views
    621

    I went on an oil furnace maintenance a couple...

    I went on an oil furnace maintenance a couple months ago and serviced system. Routine maint.. I don't have my readings in front of me right now to tell you but everything was running and ok. ...
  11. Thread: stack temp

    by joe2003
    Replies
    12
    Views
    2,242

    furnace approximately 8-9 yrs old

    furnace approximately 8-9 yrs old
  12. Thread: stack temp

    by joe2003
    Replies
    12
    Views
    2,242

    filters are clean, vents open. Bard furnace, I...

    filters are clean, vents open. Bard furnace, I don't have the model and serial # at this time with a becket burner, I believe the model was AG but I am not certain.
  13. Thread: stack temp

    by joe2003
    Replies
    12
    Views
    2,242

    Oil furnace no.2 fuel oil. What would a normal...

    Oil furnace no.2 fuel oil. What would a normal stack temperature be, what would be considered too high or too low? If too high what would be causes and if too low, causes. I have been told between...
  14. Thread: capacitors

    by joe2003
    Replies
    7
    Views
    945

    Am I not asking the question right?

    Am I not asking the question right?
  15. Thread: capacitors

    by joe2003
    Replies
    7
    Views
    945

    What causes the high voltage reading across the...

    What causes the high voltage reading across the terminals of a run capacitor??
  16. Thread: low cooling

    by joe2003
    Replies
    5
    Views
    724

    been up for 7 days

    been up for 7 days
  17. Thread: low cooling

    by joe2003
    Replies
    5
    Views
    724

    units been on for 3 7 days, bulb is not...

    units been on for 3 7 days, bulb is not insulated. I am having this debate in another post about the insulated txv. That post was from today, go ckeck it out. I think that is the problem too
  18. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    Originally posted by beenthere [B]With a...

    [QUOTE]Originally posted by beenthere
    [B]With a txv, if you take your indoor wetbulb, you know what your keaving drybulb temp should be.

    Does it get to set point but continue to run, or is the...
  19. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    indoor wet bulb not taken because txv metering...

    indoor wet bulb not taken because txv metering device, od ambient 85-90, I took coil delta but i'm not sure what it was at this time, complaint is unit not shutting off
  20. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    go to my earlier post to get that info, thanks

    go to my earlier post to get that info, thanks
  21. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    then why does my suction pressure never move, do...

    then why does my suction pressure never move, do u think the the TXV could be stuck open and refrigerant is free flowing through coil??
  22. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    inside the plenum or inside the coil case what is...

    inside the plenum or inside the coil case what is the difference, because i don't understand
  23. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    it was not a cased coil. sheet metal was built...

    it was not a cased coil. sheet metal was built around the coil, thats what i call the plenum, am i incorrect?????
  24. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    final answer

    final answer
  25. Thread: TXV

    by joe2003
    Replies
    22
    Views
    1,463

    Does a TXV bulb need to be insulated if it is...

    Does a TXV bulb need to be insulated if it is inside the plenum on the outlet of the evaporator?? I have a new replacement that has low cooling and the unit runs all the time. I spoke of this unit...
Results 1 to 25 of 48