Search:

Type: Posts; User: smilies

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Pretty sure the chiller dreams popped at Hussmann...

    Pretty sure the chiller dreams popped at Hussmann a couple months ago. They dabbled under Ingersoll Rand, as they do have the means, but wasn't really clicking as Hussmann stand alone. They hired a...
  2. Thread: Smoke stick?

    by smilies
    Replies
    14
    Views
    825

    The smoke sticks I used from the supply house...

    The smoke sticks I used from the supply house emptied out that side of store. A journeyman recommended incense sticks and it works really well without the heavy smoke. I place 3-4 on the top shelf...
  3. What was the oil mgmt system used with the...

    What was the oil mgmt system used with the Hussmann TD? I ask because there are several stores with a similar setup; 2 comps for LT, 2 for MT and 2 for HT...all on common piping and one receiver. ...
  4. Replies
    17
    Views
    1,871

    Incandescent bulbs are also resistive loads. ...

    Incandescent bulbs are also resistive loads. They are heaters.
  5. Replies
    9
    Views
    1,497

    :grin2::grin2::grin2:

    :grin2::grin2::grin2:
  6. Replies
    16
    Views
    4,007

    I've also bought THESE...

    I've also bought THESE thanks to another link posted here years ago. Seems all they have left are part #'s RF3, RF16, RF67 and RF72.
  7. Replies
    16
    Views
    2,817

    I had nothing to add by the time I read this, but...

    I had nothing to add by the time I read this, but I am impressed by your follow through with this issue. Can see why John speaks highly of you.
  8. Thread: 2006 E350

    by smilies
    Replies
    7
    Views
    884

    Which is voted funniest movie of all time...

    Which is voted funniest movie of all time
  9. Replies
    4
    Views
    710

    Another tip. Use the recovery machine to pump...

    Another tip. Use the recovery machine to pump into the suction header instead of tanks.
  10. Replies
    30
    Views
    3,305

    Yes, and sadly after the "PM" has been completed.

    Yes, and sadly after the "PM" has been completed.
  11. Replies
    6
    Views
    690

    Yup, have several, 410a Munters units in the...

    Yup, have several, 410a Munters units in the desert run over 600# discharge, but that PT scale is wrong,
  12. Thread: R409a problems

    by smilies
    Replies
    19
    Views
    2,843

    If the thermostat is satisfying and shutting...

    If the thermostat is satisfying and shutting down, why not turn down the thermostat?? Also, you may have overcharged the unit, torch the receiver to find the level.
  13. Replies
    19
    Views
    2,430

    I phone up the guy on EVERY callback. Not an ass...

    I phone up the guy on EVERY callback. Not an ass chewing, just a 'this is what I found' deal. If he has pride, things will change. If not, talk to the boss. I also tell every guy that I want a...
  14. Replies
    11
    Views
    1,122

    Take a glance at the TXV external equalizer, see...

    Take a glance at the TXV external equalizer, see if it is bypassing into the suction, it may be why the suction line is a lot colder than the other unit but the coil itself is warm. Or the coil is...
  15. Replies
    10
    Views
    1,485

    IR here...we get 100% match up to 6% deduction. ...

    IR here...we get 100% match up to 6% deduction. Trane must have had it better because ours did not get axed.
  16. Replies
    17
    Views
    2,115

    An experienced manager is more understanding that...

    An experienced manager is more understanding that the newly promoted hot shots. Finding those are satisfying, though.
  17. It it's 134a, that HPC needs to be at least 100#...

    It it's 134a, that HPC needs to be at least 100# lower and the CFM cut in lower
  18. Thread: RTU smokie

    by smilies
    Replies
    12
    Views
    1,469

    Thanks, ascj

    Thanks, ascj
  19. Thread: TXV bypass

    by smilies
    Replies
    5
    Views
    846

    That is not a bypass. It also does not equalize...

    That is not a bypass. It also does not equalize high and low side in the off cycle, as some believe. That senses pressure at the outlet of multicircuited coils to compensate for the bigger pressure...
  20. Thread: TXV bypass

    by smilies
    Replies
    5
    Views
    846

    Are you talking about the external equalizer???? ...

    Are you talking about the external equalizer???? Is this 'bypass' coming off the valve body or the piping before the valve??
  21. Thread: RTU smokie

    by smilies
    Replies
    12
    Views
    1,469

    Dern, was hoping this was some kind of new thing,...

    Dern, was hoping this was some kind of new thing, or some plausible explanation.
  22. Replies
    5
    Views
    817

    Including the ambient fans up top and the fans...

    Including the ambient fans up top and the fans under the roof panels?
  23. Replies
    25
    Views
    2,361

    #2 can happen if a mechanical subcooler is being...

    #2 can happen if a mechanical subcooler is being used to increase capacity. If the rack is a little low then the liquid is no longer at 50*F but a lot warmer. All the fixture TXV's open up, trying...
  24. Thread: RTU smokie

    by smilies
    Replies
    12
    Views
    1,469

    RTU smokie

    Reefer guy here but saw this and it interested me. The first 2 pics are one unit and the second 2 pics are another unit. That PVC goes to a smoke detector inside the blower compartments and, as you...
  25. Replies
    28
    Views
    4,727

    Yes, I see it done. It then gets replaced with a...

    Yes, I see it done. It then gets replaced with a commercial grade 20a device. The sparky showed me the code where it was acceptable. Mostly, it just gets wired in hot off of coil power.
    Oh, the...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event