  1. Another HO bites the dust.

    Another HO bites the dust.
  2. He is the same tech who tells HO his refrigant is...

    He is the same tech who tells HO his refrigant is stale, and it needs changed.
    Stud
  3. That furnace has a single stage PSC motor. The...

    That furnace has a single stage PSC motor. The furnace does not support 16 SEER.

    Another homeowner bites the dust.

    Goodman is a good product, poor HVAC installs give them a bad name.

    STUD
  4. If they were worth their salt, they would hand...

    If they were worth their salt, they would hand you a AHRI copy of the cert. also register it on line for you, give you a copy.
    Hacks will hope you don't register it on line, it would only give you a...
  5. That cased evap coil has a piston, not sure you...

    That cased evap coil has a piston, not sure you can get 16 SEER, need the furnace mod number
  6. I hope you haven't paid them yet. They sound like...

    I hope you haven't paid them yet. They sound like hacks. Post pictures of your concerns. Did they pull a permit, have it code inspection and size it IAW manual J ?
  7. Ask for an AHRI certificate. If the contractor is...

    Ask for an AHRI certificate. If the contractor is a pro he should have given him one. Make sure he registered it on line for you to get Warranty
  8. No I don't do home warranty. I do believe in...

    No I don't do home warranty. I do believe in haveing integrity in charging a fair price. I knew a contractor who would add a XXX.xx in his invoice for EPA compliance. He would tell them he had to it...
  9. Beenthere, $ to put old compressor in truck,...

    Beenthere,

    $ to put old compressor in truck, give them the option. While the HO is not looking why not get their billfold.
    Stud
  10. Replies
    7
    Views
    214

    I hope that price includes a complete duct job...

    I hope that price includes a complete duct job and a high seer unit.
  11. Replies
    109
    Views
    5,893

    He is wrong

    He is wrong
  12. How do you think the warranty tech makes his...

    How do you think the warranty tech makes his money?
    Another home owner bites the dust.
    Disposal fee? What is there to dispose of, your refrigerant is gone?

    Stud
  13. Replies
    18
    Views
    887

    Your Carrier's small copper tube should be...

    Your Carrier's small copper tube should be insulated. I hope it's insulated in the wall to the indoor unit. It's low pressure, MD in outdoor unit.
    Tell your neighbor to call contractor back out and...
  14. some things don't look exactly right on that load...

    some things don't look exactly right on that load calculation. what do they mean by equipment load
  15. Red flag, 5 tons for 2000 sq ft? What did the...

    Red flag,
    5 tons for 2000 sq ft? What did the manual J show as sensible heat gain?
    Can u post the manual j work sheet?
    400 sq ft per ton doesn't sound good.
    Stud
  16. There is heat energy down to -459 fahrenheit,...

    There is heat energy down to -459 fahrenheit, theoretically a heat pump can remove energy.
    Keep your heat pump running even at low OAT.

    STUD
  17. Replies
    3
    Views
    464

    Randy, Read the instruction, if you don't have...

    Randy, Read the instruction, if you don't have them do a web search. Call Honeywell tech support for help. If all fails call a Nate certified/licened HVAC tech for a service call.

    STUD
  18. Replies
    47
    Views
    3,767

    Had complaint of odors from duct work. Furnace...

    Had complaint of odors from duct work. Furnace with cased coil in closet, took the coil cover off and on top of the slant evap coil was a lb of raw hamburger meat.
    Manager said last tenets left mad....
  19. Replies
    38
    Views
    2,407

    What is the name of your company? I'm retiring, I...

    What is the name of your company? I'm retiring, I can recommend some of my customers.
    Like you, HVAC is my passion. Good luck.
    Stud
  20. are you changing out the air conditioning coils?

    are you changing out the air conditioning coils?
  21. if this is a new heat pump call the installers...

    if this is a new heat pump call the installers back out something is wrong. If they say a 45 breaker is fine get another Tech.
  22. Replies
    13
    Views
    1,265

    Tecjunkie, don't get a service contract on a 14...

    Tecjunkie,
    don't get a service contract on a 14 year old unit.
    Have a service call and have them clean the coils.
    Any company you get is going to try to sell you a unit.
    Stud
  23. Replies
    13
    Views
    1,265

    The service contracts that get me is the ones...

    The service contracts that get me is the ones that are twice a year on a heat pump. How can a heat pump need checked twice a year.
    Also how can a new heat pump need service? A new HP should only...
  24. Contractor needs to address the ductwork. The...

    Contractor needs to address the ductwork. The unit is only as good as the installation. Demand quality from contractor. Stud
  25. I would think quiet and comfort in a bedroom...

    I would think quiet and comfort in a bedroom would be paramount.
    Stud
  26. Did you and the contactor consider a ductless min...

    Did you and the contactor consider a ductless min split? That system is to big for 500 sq ft

    Stud
  27. I hope all works out. There are lots of HVAC ...

    I hope all works out. There are lots of HVAC contractors who are very good at what they do and follow ACCA guidelines. Look at your case, who benefited from oversized A/C system, not you. The...
  28. Teddy Bear, This is stud, you are giving the ho...

    Teddy Bear,
    This is stud, you are giving the ho to much info, the bottom line is the house sized IAW manual j,d and s. Did they follow ACCA installation procedure. I think not.

    How can we advise...
  29. you do not have enough return. contractor should...

    you do not have enough return. contractor should have corrected that when he wanted to put a 5 ton in. That unit is a top of the line unit, two stage with var sp blower gas furnace. You are probably...
  30. Where to start, do you know a good lawyer? Let's...

    Where to start, do you know a good lawyer? Let's let my peers chime in on this thread, see what they say. I'm to mad right now, another home owner bits the dust. Where in Texas are you? How old is...
  31. Five tons for 1800 square feet, do you think...

    Five tons for 1800 square feet, do you think maybe you want to look at that. What did the manual J worksheet call for?

    You are in big trouble you will always have a humidity problem. what's next...
  32. Where are you getting its against epa rules to...

    Where are you getting its against epa rules to install a R-22 system? Its against the EPA to manufacture a R-22 system, with R-22 in the system. Manufacturing found a loop hole in the rule, and can...
  33. If you found a 10 seer, R-22 brand new in the...

    If you found a 10 seer, R-22 brand new in the box, split or package unit, you can install it. The EPA/government does not care. Manufacturers can't make anything less than 13 seer since,2006. They...
  34. Replies
    10
    Views
    1,014

    recommend a thermostat for me

    I need a non programmable 2 stage thermostat that will bring on auxiliary heat on long run time instead of two degree setting change. Example, if tsat is not satisfied in ten minutes, the second...
  35. I sure hope you didn't pay them already. Why do...

    I sure hope you didn't pay them already. Why do contactors keep oversizeing. Looks like the attic has plenty of room, why didn't they mount it horizontal. Putting a return filter at the unit, how...
  36. Replies
    2
    Views
    559

    I miss that sorry disregard

    I miss that sorry disregard
  37. Replies
    2
    Views
    559

    y'all seen this?

    http://sporlanonline.com/smart/
  38. Replies
    6
    Views
    519

    did you read the instructions?

    did you read the instructions?
  39. Thread: A/C Renew

    by HVAC/Stud
    Replies
    31
    Views
    4,661

    I agree!

    I agree!
  40. Thread: A/C Renew

    by HVAC/Stud
    Replies
    31
    Views
    4,661

    I will stick by experience " only oil and...

    I will stick by experience " only oil and refrigrant should be in a system" , I don't care how many manufacturing service guidance or put out. If there is a problem do a recall and pay to have it...
  41. Thread: A/C Renew

    by HVAC/Stud
    Replies
    31
    Views
    4,661

    Only two things should be in the system, oil and...

    Only two things should be in the system, oil and refrigrant.
    Stud
  42. Replies
    11
    Views
    969

    I install Rinnai. The venting for them is slanted...

    I install Rinnai. The venting for them is slanted down so condensation does not flow back to unit. This setup looks more like a 90+ furnace.
    Read the venting instructions. Call the company and ask...
  43. Replies
    11
    Views
    969

    What brand is the Tankless?

    What brand is the Tankless?
  44. Replies
    9
    Views
    835

    why don't you fix the leaks then weigh in a...

    why don't you fix the leaks then weigh in a charge?
    Stud
  45. Replies
    13
    Views
    1,348

    Not easy but it can be cleaned. I cleaned one...

    Not easy but it can be cleaned. I cleaned one last week. Any HVAC technician should be able to call tech support and get help.
    Ductless/mini splits are the future of HVAC.
    You need to find the...
  46. Replies
    39
    Views
    2,826

    Jtrammel Will a $20 bill work? Stud

    Jtrammel
    Will a $20 bill work?

    Stud
  47. Replies
    7
    Views
    911

    Did the HVAC contractor install tonnage IAW...

    Did the HVAC contractor install tonnage IAW Manual J and Manual D?
    Sounds like over sized and ecm/CFM setup wrong.

    Stud
  48. Replies
    14
    Views
    1,012

    Gravity, You still need to flow nitrogen. Don't...

    Gravity, You still need to flow nitrogen. Don't advise a new tech on something that goes against industry standard. Any amount of heat will cause oxidation. Don't take short cuts.
    Stud
  49. Replies
    5
    Views
    670

    I would be more concerned with the right size...

    I would be more concerned with the right size unit. was a manual J and Manual d completed.
    5 tons is a lot.

    Stud
  50. Replies
    14
    Views
    1,012

    Oxy/acetylene the only way to go, get on get off...

    Oxy/acetylene the only way to go, get on get off quickly. Flow nitrogen and you will have no problem.

    Stud