Search:

Type: Posts; User: Lifer

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Thread: BAYSTAT053A

    by Lifer
    Replies
    7
    Views
    553

    Thanks rundawg

    Thanks rundawg
  2. Thread: BAYSTAT053A

    by Lifer
    Replies
    7
    Views
    553

    Maybe I wasn't clear. The Trane stat number is...

    Maybe I wasn't clear. The Trane stat number is BAYSTAT053A. 415141
  3. Thread: BAYSTAT053A

    by Lifer
    Replies
    7
    Views
    553

    BAYSTAT053A

    I have been looking over the web for some installation instructions for this Trane t'stat tonight with no success. This has been teamed up with a THC092 R.T.U. Is there someone that can help me out...
  4. Replies
    4
    Views
    1,145

    We installed one this past winter here in S.E....

    We installed one this past winter here in S.E. NC, it has been a good running piece of equipment. Bryant system 4 tons and 4 zones. When I started it up the house was under construction and outside...
  5. Thread: Work boots!

    by Lifer
    Replies
    122
    Views
    17,637

    I'm wearing a new boot to me. Georgia Boot....

    I'm wearing a new boot to me. Georgia Boot. http://www.georgiaboot.com/ I have to say I am pleased with the fit. They had a pdf. file that you print and measure your size. I have been wearing mine...
  6. I have been using an H-10 for the past 20 yrs....

    I have been using an H-10 for the past 20 yrs. and have found that it is always done a great job at making money with leaks. I have seen other techs come and go, with other units and nothing beats...
  7. Thread: Heat Controller

    by Lifer
    Replies
    7
    Views
    968

    That's a Nordyne for sure. The fan is the same as...

    That's a Nordyne for sure. The fan is the same as the Nordyne, and with the plastic bottom it has to be Nordyne.
  8. Thread: H-10 guru's

    by Lifer
    Replies
    25
    Views
    2,570

    Bob the Bull has it right. I got my first H-10...

    Bob the Bull has it right.
    I got my first H-10 "B" back some 20 yrs ago.
    I love them and once you use them and get a feel for it then you will not leave it.
  9. Replies
    26
    Views
    5,170

    No aux. drain pan under unit here in NC that is...

    No aux. drain pan under unit here in NC that is code violation, and code is the minimun standard. What happened to the strapping the flexibile duct at least for the return duct. Shouldn't you put...
  10. Replies
    20
    Views
    3,761

    I live in wilmington NC and I have been using...

    I live in wilmington NC and I have been using Cal. Econo. systems. I have used Mr. Goins in the early days of the system 1000 controllers and I have had nothing but good service from both systems and...
  11. Replies
    2
    Views
    628

    I never use reclaimed refrigerant ALWAYS virgin...

    I never use reclaimed refrigerant ALWAYS virgin refrigerant.
  12. Replies
    47
    Views
    8,344

    So if the primary drain cloggs then water fills...

    So if the primary drain cloggs then water fills the emergency pan (under the air handler) and drains fine through the emergency drain line but doesn't shut off the system because it dosen't fill high...
  13. Replies
    7
    Views
    2,083

    Here on the coast of N.C. there is little heat...

    Here on the coast of N.C. there is little heat load and high cooling loads. The last gas pack I installed was around this time last year. Then I installed a GPG1230070 Johnstone supply told me that...
  14. Replies
    7
    Views
    2,083

    Hey Robo is there a way you can relay the need...

    Hey Robo is there a way you can relay the need for a low Btu gas pack in the goodman line say 50k.
  15. Replies
    15
    Views
    1,535

    I did as the instructions said but the unit shook...

    I did as the instructions said but the unit shook and fell out the window and hit the man walking down the street. Please write back and tell me how to get the window shut before the cops come and...
  16. Thread: Amana

    by Lifer
    Replies
    6
    Views
    854

    RoBoTeq, Hey If you would not like to recomend...

    RoBoTeq,

    Hey If you would not like to recomend a matching unit that is ok.
  17. Thread: Amana

    by Lifer
    Replies
    6
    Views
    854

    RoBoTeq, Thanks for the quick reply. ...

    RoBoTeq,

    Thanks for the quick reply.
    Changing the outdoor unit and I was wandering if a cplj or a cplt would match up ?
  18. Thread: Amana

    by Lifer
    Replies
    6
    Views
    854

    Hey can any one tell me what SEER rating is this...

    Hey can any one tell me what SEER rating is this system and does the air handler have a TXV

    Amana
    Indoor # BHA30FA002A
    Outdoor # RHD30A2A
  19. Replies
    14
    Views
    1,665

    r22 systems uses mineral oil and it doesn't mix...

    r22 systems uses mineral oil and it doesn't mix with P.O.E. oil that is used in 410 systems it is like water and oil.
  20. Replies
    14
    Views
    1,665

    Too late damage is already done to 410 system.

    Too late damage is already done to 410 system.
  21. Replies
    24
    Views
    2,212

    Did you do a load calc on the building? Sounds...

    Did you do a load calc on the building? Sounds like the equipment is under sized. Is the fan settings correct?
  22. Replies
    9
    Views
    3,543

    Variable speed is the way to go. Yes...

    Variable speed is the way to go. Yes dehumidification is great but also there is no cold starts in heat mode either. Trane VS units have a 50% setting for constant blower mode which is good for air...
  23. Replies
    37
    Views
    5,129

    I work with a oxy/acet set up that way I can...

    I work with a oxy/acet set up that way I can regulate the heat needed for the most part but when I go into an attic I take my mapp turbo torch.

    When I run line sets I use just heat to melt copper...
  24. Thread: Memorial Day

    by Lifer
    Replies
    4
    Views
    630

    Thank God Thank a Vet.

    Thank God

    Thank a Vet.
  25. Replies
    26
    Views
    2,441

    I don't know about your customers but we have...

    I don't know about your customers but we have only perferred customers.
    When a customer calls we try to serve their need in a timely fashion. If we don't someone else will.
  26. Thread: Leak detectors

    by Lifer
    Replies
    16
    Views
    1,827

    H-10 Everyone says that theirs is equal to the...

    H-10 Everyone says that theirs is equal to the H-10.

    I have been using mine for 10 years.

    Works great.
  27. Replies
    49
    Views
    3,238

    I set many a Trane units and I have had two with...

    I set many a Trane units and I have had two with a noise complaint that happened to be the hot gas tube knocking on the base. GOOD CALL Mark. I say give the dealer a try at fixing the noise and if...
  28. Thread: to pay or not

    by Lifer
    Replies
    8
    Views
    1,185

    Well be honest to the contractor and tell them...

    Well be honest to the contractor and tell them that you have got estimates that range from blank to blank and before they install that you would like them to do a calc.

    For me to do a block load...
  29. Replies
    17
    Views
    1,623

    Add nitrogen to 100 psig. and test with soap...

    Add nitrogen to 100 psig. and test with soap bubbles or leave over night.
  30. Thread: Goodman

    by Lifer
    Replies
    24
    Views
    2,859

    I once worked with a contractor that did...

    I once worked with a contractor that did apartment buildings and with them there it was about 1 percent that had problems and then with goodman it your cookie.
  31. Replies
    28
    Views
    3,809

    Here in my area insulation can't be crushed by...

    Here in my area insulation can't be crushed by straping and if it has been then a additional layer of insulation is required.
    All primary drains above a ceiling in to be insulated. I would also...
  32. Thread: Heat Pump

    by Lifer
    Replies
    32
    Views
    2,379

    Robo can you explain this. If this is true then...

    Robo can you explain this. If this is true then for the past 15yrs I have been missing this in my diagnosis.
    Are you talking about the heatpump or the air handler.

    Thanks.
  33. Replies
    5
    Views
    936

    I have one builder that pays me to bid a job and...

    I have one builder that pays me to bid a job and he is a great guy he knows what it is like.
    He is a great builder and I treat him right and he returns the favor.
    As long as I get a bill in be4...
  34. Replies
    19
    Views
    2,116

    Trane A/S recip compressors the rotolock kind are...

    Trane A/S recip compressors the rotolock kind are as tough as the scroll. Amer.Stand. has been putting them in for years and they have stood the test of time. Many of the dealers here have said why...
  35. Thread: Mold and AC size

    by Lifer
    Replies
    3
    Views
    1,187

    Airman You aren't saying that going with a...

    Airman
    You aren't saying that going with a lennox dealer insures that you don't get mold in your duct system ?

    Here in my area we are a heatpump area and yes I see moldy systems but there is...
  36. Replies
    6
    Views
    921

    Find a contractor that has done homes to E.P.A....

    Find a contractor that has done homes to E.P.A. standards for a Star Energy home then have them do the duct system to those standards and have it tested for leaks by a seperate firm that is impartial...
  37. Replies
    26
    Views
    3,405

    Here at this web site adv. energy offer a book...

    Here at this web site adv. energy offer a book that is a real help I live in wilmington NC after the hurricane Floyd this research company got a federal grant to come up with ways to dry out our area...
  38. Thread: Hot upstairs

    by Lifer
    Replies
    11
    Views
    1,968

    Putting in a duct fan in the return might blow...

    Putting in a duct fan in the return might blow dust off the other return filters in the system bacause there is less resistance there than the A coil.

    Leave the switch on the thermostat for the...
  39. Thread: heat pump choice

    by Lifer
    Replies
    5
    Views
    1,003

    I like florida's GTO series with the two...

    I like florida's GTO series with the two compressors. 40% -60% to 100% system
  40. Replies
    65
    Views
    7,024

    Dirty sock syndrome is when micororganisiums in...

    Dirty sock syndrome is when micororganisiums in the a coil leave their waste in the coil when the uniy goes to defrost that is when the waste gets moist and then unit goes to heat and the coil gets...
  41. Replies
    3
    Views
    1,016

    Hey The TWE031 control board set it for 2 ton...

    Hey
    The TWE031 control board set it for 2 ton on first 2 switches
    Then set next switches for 400 cfm
    Then next switches for enhanced mode
    then set the next 2 switches for 800 cfm
  42. Replies
    34
    Views
    3,495

    Here in NC you cannot install commercial cooking...

    Here in NC you cannot install commercial cooking equipment in a residence the Dept. of Insurance will not insure a house with it so when you try to get a cert. of occupation to move in inspection...
  43. Replies
    12
    Views
    1,810

    I worked at a hampton inn and there we finished...

    I worked at a hampton inn and there we finished the building and started another job a marioit for same builder and when we were at the marioit the fire sprinklers ah a pipe rupshure and flood 4...
  44. Replies
    26
    Views
    2,584

    I went to one of the sites and they refered me to...

    I went to one of the sites and they refered me to my company as a contractor that would install their units. I sent them an e-mail and thanked them for the thought of confidence but I asked them to...
  45. Replies
    8
    Views
    1,487

    F.H.P. Heatpumps have a lockout relay that looks...

    F.H.P. Heatpumps have a lockout relay that looks like a delay timer that may be going bad also all the other listed senireos. sorry about the spelling.
  46. Replies
    26
    Views
    2,584

    Go to the manufactures web site and read their...

    Go to the manufactures web site and read their warranty the warranty states no warranty for goods purchased over the internet.
  47. Replies
    11
    Views
    1,145

    I use a #8 X 3/4" zip screw I just start the...

    I use a #8 X 3/4" zip screw I just start the screw and let it bite into it then grab the screw with a pair of pliers and pull it out.
  48. Replies
    10
    Views
    1,022

    Sounds like the O circuit is energized some how.

    Sounds like the O circuit is energized some how.
  49. Replies
    10
    Views
    1,686

    I learned it from the Community College in my...

    I learned it from the Community College in my town at night. Check if your community college has the course. there I learned from a Man J book and a Man D book. This has been very helpful to me...
  50. Replies
    22
    Views
    5,641

    I use the 3" mastic tape on metal joints. I...

    I use the 3" mastic tape on metal joints.

    I use the UL181FB tape that has the thread in it for the flex to metal joint. The mylar tape seems to me will after time get hard and then dirty and fall...