Search:

Type: Posts; User: GenesisRefrig

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Evacuation recommendation for iPod that got wet

    OK, strange, I know... My son accidentally washed his iPod while doing laundry. Although it is very clean, I want to get the water out.

    I've done the bag of rice trick for two days, and it powers...
  2. Replies
    2
    Views
    675

    Homeowner Install

    Been working for 20 years. No heat call today. 120,000 BTU. Should have been 60,000 but more is better, right?

    Bottom return with a wooden plenum. Plenum leads to a combination wood/cardboard R/A...
  3. Replies
    21
    Views
    811

    -18F here this morning. Right now, 6:30PM, It's...

    -18F here this morning. Right now, 6:30PM, It's -1F. Northern MN.
  4. Replies
    17
    Views
    1,053

    Oh crap. I didn't read the post very well. I was...

    Oh crap. I didn't read the post very well. I was writing about Nu-Calgon Easy Seal. I see we were talking about A/C Renew. Sorry. Never used it.
  5. Replies
    17
    Views
    1,053

    OK, I've NEVER been partial to snake oil, but I...

    OK, I've NEVER been partial to snake oil, but I had this job where the leak was buried in the wall of a finished building and shutting the restaurant down for repair was not a good option....
  6. What N2Fords said. Use Triple D degreaser. I...

    What N2Fords said. Use Triple D degreaser. I think it's made by Diveritech. Best degreaser I've ever used.
  7. Thread: beacon I

    by GenesisRefrig
    Replies
    17
    Views
    818

    I don't know if we can post prices here, but the...

    I don't know if we can post prices here, but the KE2Therm Evap Efficiency is reasonably priced and works with many EXV's. Their customer service is second to none. Available 24/7. Talk to...
  8. Replies
    2
    Views
    468

    Recovery: Appion G5 Twin Vacuum Pump: JB DV142...

    Recovery: Appion G5 Twin
    Vacuum Pump: JB DV142
    Leak Detector: DTec Select
    Torch set: Get oxy acetylene with extra set of tanks. Most versatile.
    Micron guage: Thermal Engineering
    Meters: Fluke...
  9. Replies
    77
    Views
    7,622

    One tool that goes on almost every job is my...

    One tool that goes on almost every job is my rechargeable Streamlight Stinger LED DS flashlight. Guaranteed for life, it sits in the dash charger until I get to the job. It's always fully charged and...
  10. Replies
    64
    Views
    3,332

    Agreed on Thermal unit. Mine is 19 years old and...

    Agreed on Thermal unit. Mine is 19 years old and still spot on accurate.
  11. Replies
    42
    Views
    1,653

    I would install an adaptive defrost controller....

    I would install an adaptive defrost controller. KE2Therm makes a great one. The controller senses frost, Evap efficiency, and door opening and defrosts only when necessary.

    We installed one in a...
  12. Replies
    13
    Views
    2,866

    Home made toaster.... Or... Maybe the installer...

    Home made toaster.... Or... Maybe the installer did it this way so the heat from the glowing strands would keep the control compartment warm in cool weather.
  13. Nope. It's a cheap bi-metal stat.

    Nope. It's a cheap bi-metal stat.
  14. Looking for stat for Delonghi heater

    Portable Delonghi oil filled heater M# 5108
    Line voltage, single pole, bimetallic, snap action contact, thermoregulator.
    16A at 250v
    6C-70C (43F-158F)
    Part #. Campini TY.53

    I've been...
  15. Replies
    12
    Views
    1,040

    Some valve stems have a nut with two flats that...

    Some valve stems have a nut with two flats that can be tightened to seal a leak. If yours doesn't, I would replace the valve. It's money for you, and the customer gets it done right.
  16. Replies
    29
    Views
    1,833

    I can knock out two in a day with a helper. ...

    I can knock out two in a day with a helper. Complete with drain, line set ducting, and electrical (I have sparky install the disconnect before we begin).
  17. Mike, Thanks for the quick reply and for the...

    Mike,

    Thanks for the quick reply and for the manual link! I appreciate it.
  18. Help. I.D. This Beverage Air Compressor

    Dead compressor on Beverage Air, single door display cooler running R-12. Model number MT-27. The compressor looks like a Techumseh, but the metal tag was removed by the factory and this paper lable...
  19. Perhaps your meter is set wrong or the leads are...

    Perhaps your meter is set wrong or the leads are plugged in wrong... RSES is running an ELECTRICAL METER USAGE webinar on March 26. They are usually pretty informative.
  20. If you did it this way, wouldn't you bring...

    If you did it this way, wouldn't you bring relatively humid air from the cooler into the freezer that would affect coil frosting and load?
  21. Replies
    49
    Views
    3,383

    If you dint have time to do it right... You...

    If you dint have time to do it right...

    You must have time to do it over.
  22. Replies
    34
    Views
    1,612

    Strange as it might seem, there are some...

    Strange as it might seem, there are some residential refrigerators that will not cool without the cardboard back in place. The condenser air just travels through the fan and is not pulled across the...
  23. Replies
    39
    Views
    3,048

    We are talking parallel rack with 4 compressors....

    We are talking parallel rack with 4 compressors. Common discharge and suction headers.

    I sure do appreciate all the replies. You guys are wonderful (don't get big heads now). I'll be sure to post...
  24. Replies
    39
    Views
    3,048

    Isolating with valves. Almost everything is...

    Isolating with valves. Almost everything is overhead. No pits. One line buried.
  25. Replies
    39
    Views
    3,048

    Yeah, that's what I was thinking. Checked the...

    Yeah, that's what I was thinking. Checked the condenser, checked the heat reclaim piping. Checked everywhere that was easily accessible. No luckj. I hate these calls! Hundreds of feet of insulated...
  26. Replies
    39
    Views
    3,048

    Finding a leak in grocery store...

    Just got called to a grocery store. Mid temp rack (3 compressors running R-22) with 12 circuits. Low on refrigerant. Was serviced by another company about 2 months ago. They fixed a leak and filled...
  27. Replies
    204
    Views
    34,194

    Working part time law enforcement, I learned what...

    Working part time law enforcement, I learned what real quality lights were. Officers routinely compare their flashlights like some kind of status symbol... Who's got the best, brightest, longest...
  28. Replies
    18
    Views
    1,823

    Yes, according to Highside it does. I've only...

    Yes, according to Highside it does. I've only used it on evaps though. According to their website, it's been tested in excess of 3,000 psi on stainless. It is good to 350F. ...
  29. Replies
    18
    Views
    1,823

    Red Epoxy from Highside Chemicals. Awesome stuff....

    Red Epoxy from Highside Chemicals. Awesome stuff. Mix it up, put it on the leak, hit it with a heat gun until it changes color from red to gold. Evacuate, charge, and put it back in operation.
    ...
  30. Replies
    25
    Views
    2,268

    Your customer would need a phase converter. Many...

    Your customer would need a phase converter. Many people are using these in our rural areas where 3 phase is not available. Grainger has some. ...
  31. Replies
    14
    Views
    2,112

    Just wanted to bring an update to the original...

    Just wanted to bring an update to the original post. We located the area where the tank was leaking. Cut an access in the outer shell and hired a tig welder to fix about a 1/4 inch crack in the...
  32. Replies
    24
    Views
    4,509

    Got above zero this week so went to the car wash...

    Got above zero this week so went to the car wash (only one in 12 miles). Car wash has frozen pipes and won't be open again for months.
  33. Replies
    16
    Views
    2,223

    At least he installed a filter/dryer. A lot of...

    At least he installed a filter/dryer. A lot of hacks don't.
  34. Thread: Snow

    by GenesisRefrig
    Replies
    17
    Views
    2,509

    Just bought a new service vehicle. 461021 ...

    Just bought a new service vehicle.
    461021

    Seriously, I have used my snowmobile to make service calls. 3 feet of new snow. 4wd wouldn't work, so took sled to hospital to fix walk in freezer.
  35. Replies
    38
    Views
    2,584

    Been chasing a leak for two years at a butcher...

    Been chasing a leak for two years at a butcher shop. Put the dye in and found the leak a couple months later. I wish I took a picture because it was leaking out of a 1 foot length of 1-1/8 copper...
  36. Replies
    16
    Views
    1,100

    What does ASC mean?

    What does ASC mean?
  37. Replies
    16
    Views
    1,100

    Yeah, first time working with these. Some...

    Yeah, first time working with these. Some screenshots below.

    Home screen to access schedules, groups, controllers, databases, etc.
    459691

    Controllers screen to access each individual...
  38. Replies
    16
    Views
    1,100

    Beautiful looking work. Thanks for the offer......

    Beautiful looking work. Thanks for the offer... I'd love to have a copy so I can make art like that.
  39. Replies
    16
    Views
    1,100

    Graphical programming. The only complaint I...

    Graphical programming.

    The only complaint I have is that I wish it was more open and customizable, but that is also a strength as the on site maintenance personnel can't screw it up too bad.
  40. Replies
    32
    Views
    3,058

    +1 on JB Fittings. Get the straight and angled...

    +1 on JB Fittings. Get the straight and angled quick disconnect fittings.
  41. Replies
    16
    Views
    1,100

    Taco iWorx Install Complete

    Just got done with a job at a nursing home. Replaced old pneumatics and electro-mechanical Johnson Controls mess with the iWorx system by Taco. We converted:
    3 face & bypass systems using 100% O.A....
  42. Replies
    643
    Views
    120,193

    New customer called and said the freon in his...

    New customer called and said the freon in his walk-in needed to be changed because the cooler was too warm. Whatever... The only refrigeration word customers know is freon... I got on site and the...
  43. Replies
    11
    Views
    1,001

    I bought the bender this Summer and it stripped...

    I bought the bender this Summer and it stripped out the teeth after the first month. Returned it and bought a Yellow Jacket with reverse bender accessory. I love the Yellow Jacket.
  44. Replies
    17
    Views
    1,170

    I love the "Thank You's" and gratitude from...

    I love the "Thank You's" and gratitude from satisfied customers. Someone is having a bad day… I show up, fix the problem, charge a fair price and get them out of a jam. It's awesome to be able to...
  45. Replies
    4
    Views
    705

    +1 Oil from gearbox getting into evap.

    +1

    Oil from gearbox getting into evap.
  46. Yep. Replace condensing unit, TXV, disconnect...

    Yep. Replace condensing unit, TXV, disconnect door heater and electric defrost heaters. Also, seal off pressure relief vent (if equipped, usually in door panel). Unplug heat tape on drain.

    Check...
  47. Replies
    21
    Views
    2,198

    I use a Fluke meter with a pipe clamp...

    I use a Fluke meter with a pipe clamp thermocouple. The Fluke model number is TK-80 or 80-TK. Icant remember. Works great
  48. Replies
    24
    Views
    2,142

    Just messin with your English. The word thaw,...

    Just messin with your English. The word thaw, means to melt ice, so the word "unthaw" would mean to create ice... :grin2:
  49. Replies
    24
    Views
    2,142

    No! Don't unthaw the coil. It will just make the...

    No! Don't unthaw the coil. It will just make the problem worse. :angel:
  50. Replies
    24
    Views
    2,142

    I check pressures, superheat, refrigerant charge,...

    I check pressures, superheat, refrigerant charge, frost pattern. Sound like an underfeed problem. You probably have high superheat due to low charge or an under feeding valve. Really we need more...
Results 1 to 50 of 115
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event