Search:

Type: Posts; User: ararams

Page 1 of 6 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    6
    Views
    318

    99% of the time the leak underneath there is from...

    99% of the time the leak underneath there is from the safety plug.
  2. Replies
    24
    Views
    1,884

    All txv pins are made of stainless steel,but all...

    All txv pins are made of stainless steel,but all the gunk is collecting where the pressure drop is taking place.
  3. Replies
    8
    Views
    461

    GM engines produce so much crap, they clog the...

    GM engines produce so much crap, they clog the oil pickup strainer. I even ran mobil 1, clog at 275000 miles.
  4. Replies
    27
    Views
    1,235

    Since they changed their model #S differentiating...

    Since they changed their model #S differentiating units became a pain. The SY model comes as a Quiet cube and a remote same with the Indigo.
  5. Thread: c-frame motors

    by ararams
    Replies
    13
    Views
    916

    Toward the copper bar

    Toward the copper bar
  6. Replies
    27
    Views
    1,235

    Be careful when recovering refrigerant from those...

    Be careful when recovering refrigerant from those machines. Without power to the liquid line solenoid valve refrigerant is trapped at the drier.
  7. Replies
    27
    Views
    1,235

    It seems that the building has three phase power...

    It seems that the building has three phase power supply. If true,you do not want the machine to be on the high leg if one is present.
  8. Replies
    213
    Views
    15,568

    Can a clock/timer be added? This plus recording...

    Can a clock/timer be added? This plus recording event can help find troublesome intermittent problems.
  9. Replies
    41
    Views
    3,062

    Your boss thought his initial donation to the...

    Your boss thought his initial donation to the German economy was enough, not so .If he need those vans running he have to make some more donation with each part that carries the Benz symbol.
  10. Replies
    623
    Views
    114,761

    Earlier this week I had to drive an hour plus one...

    Earlier this week I had to drive an hour plus one way for a new unit not cooling only to find the thermostat set on heat. Invoice ---- closed open low voltage circuit.
  11. Normally a rack has the equipment to handle the...

    Normally a rack has the equipment to handle the backup of liquid before it hits the compressor,on single units it's a death sentence for that compressor.
  12. I hope you don't have an aftermarket accumulator.

    I hope you don't have an aftermarket accumulator.
  13. Did you replace the low pressure control with a...

    Did you replace the low pressure control with a new one? I ask this because there was a change in the setting. You are most likely working on a 2000 lb unit
  14. Replies
    34
    Views
    1,917

    There is a reason all machines have model...

    There is a reason all machines have model numbers,without it we don't know witch unit you are looking at.
  15. Replies
    2
    Views
    383

    May be the instructions are in Japanese and no...

    May be the instructions are in Japanese and no one can read it .
  16. Replies
    14
    Views
    2,944

    That's the biggest split system I have seen.

    That's the biggest split system I have seen.
  17. Replies
    53
    Views
    6,573

    Have you checked the discharge temp? Maybe the...

    Have you checked the discharge temp? Maybe the oil has started cooking. This is common with r22 systems with run away superheat,the same can happen with 410a or any refrigerant for that matter.
  18. If the arms are getting cold, how are the the...

    If the arms are getting cold, how are the the legs.
  19. Replies
    36
    Views
    5,803

    Stupidity has no borders nor language barriers.

    Stupidity has no borders nor language barriers.
  20. Replies
    21
    Views
    1,160

    I also think he's looking at a headmaster. ...

    I also think he's looking at a headmaster. As for the cooler (where the owner turns off the fans) I normally install a relay or contactor with a coil voltage similar to the evaporator fans in a...
  21. Thread: accumulators

    by ararams
    Replies
    3
    Views
    309

    Some have them on the bottom and they sometime...

    Some have them on the bottom and they sometime leak for no apparent reason.
  22. Replies
    5
    Views
    377

    Does the compressor have a decal saying it is...

    Does the compressor have a decal saying it is protecting itself by not pumping?
  23. Most if not all the products in there are package...

    Most if not all the products in there are package products, low humidity will not really affect quality. High humidity will definitely affect your beer because if it"s slimy, slips out of your hands...
  24. Thread: Whistling TXV

    by ararams
    Replies
    10
    Views
    1,009

    That whistling noise you are hearing is the...

    That whistling noise you are hearing is the universal language txv speaks, the oscillating part comes when the pressure varies with the fan cycle control. When a valve is well fed it's quiet but the...
  25. Replies
    10
    Views
    783

    You already have your amp meter in your...

    You already have your amp meter in your hand,continue using it to check how much amps is drawn by the run and the start windings. If they are both pulling amperage then you have good windings but a...
  26. That's exactly how I look at it because we are...

    That's exactly how I look at it because we are looking at a failed part.
  27. Replies
    19
    Views
    1,839

    Look in Snapon catalog. That's where I got mine.

    Look in Snapon catalog. That's where I got mine.
  28. Thread: TXV's

    by ararams
    Replies
    35
    Views
    2,621

    That will depend on bulb charge. Gas or liquid...

    That will depend on bulb charge. Gas or liquid valves can be installed in any orientation, mix charged ( gas and liquid in the power element) power should be installed vertically.
  29. I think there is a similarity between this...

    I think there is a similarity between this expansion valve, the blown headmaster (I have actually seen this happen) and a frozen water line burst. I am sticking to rapid heating of a liquid filled...
  30. (MOP charge from what I can see. So this will...

    (MOP charge from what I can see. So this will limit the pressure produced within the sensing bulb to a predetermined limit. ) has nothing to do with sensing bulb pressure,but it limits the suction...
  31. Where can I find more info on that statement?

    Where can I find more info on that statement?
  32. Replies
    68
    Views
    6,667

    Did any of your fords disc pad set last 210,000...

    Did any of your fords disc pad set last 210,000 miles? My 05 chevy did, now I on 103,000 on a '10.
  33. Thread: Pulley puller

    by ararams
    Replies
    33
    Views
    1,994

    One of the better puller that have not failed me...

    One of the better puller that have not failed me yet. I added a socket and adapter to my impact driver and now have the all new Impact Driven Puller.
  34. Replies
    45
    Views
    2,485

    Your temperature sensing devices needs...

    Your temperature sensing devices needs recalibrating (you may need to keep your hand in a well stired mixture of ice and water ). then recheck temperatures in degrees.
  35. Replies
    27
    Views
    2,391

    The crane which cleaned that mess up did not use...

    The crane which cleaned that mess up did not use his outriggers either.
  36. Thread: Turbo torch

    by ararams
    Replies
    41
    Views
    4,270

    How many tanks do you have to parallel to braze...

    How many tanks do you have to parallel to braze 3'' copper?
  37. Replies
    40
    Views
    2,236

    The receiver level will vary with ambient. How...

    The receiver level will vary with ambient. How will you tell if the level is correct at a specific ambient?
  38. The old 502 machines had an exp with brass body...

    The old 502 machines had an exp with brass body and stainless power element. The r12 units had brass with steel.
  39. Replies
    29
    Views
    1,940

    ---The moisture and particulate capacity of each...

    ---The moisture and particulate capacity of each drier is a specific quantity, ( a 5 cubic inch can hold a maximum of 119 drops at 125 degree/50ppm per Sporlan). Until you can tell how much has been...
  40. Replies
    15
    Views
    1,368

    (I am working with a Hussmann Parallel rack in a...

    (I am working with a Hussmann Parallel rack in a super-market. I had a suction line restriction on a WIF. We identified the location based on frost formation and isolated the line. During attempted...
  41. Replies
    9
    Views
    747

    Do you happen to have a model # of the cond and...

    Do you happen to have a model # of the cond and evap?
  42. Replies
    9
    Views
    747

    The booklet you got with that unit has most of...

    The booklet you got with that unit has most of the information. You may want to read it and keep it because it has a parts list with parts numbers,something you don't get often.
  43. Replies
    28
    Views
    2,207

    Now that will be one of the first thing you will...

    Now that will be one of the first thing you will check when you are low on charge.
  44. Replies
    68
    Views
    3,916

    Do they lock out on any error codes? are the ice...

    Do they lock out on any error codes? are the ice thickness sensors embedded in ice?
  45. Replies
    68
    Views
    3,916

    You are saying (they're both froze up) is this...

    You are saying (they're both froze up) is this solid ice or frost?
  46. Replies
    68
    Views
    3,916

    I was thinking you were working on the special...

    I was thinking you were working on the special edition manitdohwoc
  47. Replies
    53
    Views
    2,870

    Add NTB tires to that list. I was told the same...

    Add NTB tires to that list. I was told the same thing a few months ago
  48. Replies
    68
    Views
    3,916

    240 psi but regardless use the OEM part. And...

    240 psi but regardless use the OEM part. And the receiver will get cool during harvest.
  49. Replies
    15
    Views
    1,046

    Are you sure? All the remote condensers I have...

    Are you sure? All the remote condensers I have seen has the control.
  50. Replies
    15
    Views
    1,046

    With low head pressure, heat cannot build up and...

    With low head pressure, heat cannot build up and be available for harvest. --------With low charge,pressure and ambient your receiver will not be cold.
Results 1 to 50 of 277
Page 1 of 6 1 2 3 4