  1. They're on propane, I wonder if the conversion...

    They're on propane, I wonder if the conversion was done, and if so, if it was done correctly. I am on propane as well, bought a clothes dryer, had it delivered, guy was going to install it, so I...
  2. It leaked condensation when installed.. So...

    It leaked condensation when installed.. So assuming everything was done perfectly in the middle of summer except for a little leak that didn't show up until the heating season, cutting the exhaust...
  3. My wife's parents' house. 4 zone hot water...

    My wife's parents' house. 4 zone hot water through the floor heat. All kinds of interference with all that piping, can't turn off some of the valves without removing the lever and turning with a...
  4. hasn't worked right since new, now 6 years old

    Like the subject says. Pretty sad. Personally, I like the added transformer strapped to the vent pipe. I certainly don't know much about HVAC, but I know this aint good... 599231599241
  5. goodman modulating gas valve, communicating t-stat

    Hello all, I have a new in box, never used CTK02 t-stat, that was swapped out under warranty. Brand new. Since at this time I don't need heat or AC, I thought if I could sell this in a timely...
  6. Replies
    8
    Views
    583

    He's looking into it, will have an answer on...

    He's looking into it, will have an answer on Monday. I was trying to cover all my bases with the "selling on my own" question, and I think my guy was just trying to cover his butt if they don't let...
  7. Replies
    8
    Views
    583

    Thanks for the reply hvacvegas. So far has that...

    Thanks for the reply hvacvegas. So far has that CTK04 proven to be a reliable unit? My tech tells me he may only be able to swap the CTK02, so if I want the CTK04 I will have to buy it and try to...
  8. Replies
    8
    Views
    583

    Hello all, I looked at the the literature on the...

    Hello all, I looked at the the literature on the the CTK04, and it does add some features that I would like over the CTK02. But does the CTK04 still allow the same programming of the fan speeds, fan...
  9. Replies
    8
    Views
    583

    Thanks for the replies. What would I gain with...

    Thanks for the replies. What would I gain with the 04 or even the 03 over the 02?
  10. Replies
    8
    Views
    583

    upgrading t-stat advice.

    My current goodman CTK-02 is being replaced under warranty, due to a bad back up battery. (see other thread) However, I might be able to get partial credit for it and get a different t-stat. I wish...
  11. Replies
    3
    Views
    276

    Corroded back up button battery with no markings...

    Corroded back up button battery with no markings soldered to the board. Not really homeowner-friendly. My tech will swap the t-stat, no problem.
  12. Replies
    3
    Views
    276

    Okay, thanks. I was looking in the user manual...

    Okay, thanks. I was looking in the user manual for instructions on changing the battery, and what battery it is. Since I didn't see a section dealing with this, I assumed it didn't have it. I will...
  13. Replies
    3
    Views
    276

    Goodman CTK02 losing time and date.

    Hi all, I have seen on the last 2 power failures (over the last month) this t-stat has needed the time and date re-entered. The power failures were less than 15 minutes each occurrence. According...
  14. Replies
    1
    Views
    285

    Changing the blower speeds via the tstat gets me...

    Changing the blower speeds via the tstat gets me the same delta t so I am thinking the txv in the outdoor unit is compensating for the different load. I would love it if someone could briefly...
  15. It's back on. Thanks for the advice. Mike

    It's back on. Thanks for the advice. Mike
  16. I should add, the very slight fractional-second...

    I should add, the very slight fractional-second light flicker I get when the HP starts bugs me. Rural area, me and the neighbor share a power transformer, he had a HP hacked-in real bad a few years...
  17. Replies
    1
    Views
    285

    expanded heating data question

    According to the chart for my equipment and my current outdoor ambient temperature, my delta T is a few degrees higher than the chart says. It always is, no matter what the outdoor temperature (I've...
  18. reason for compressor delay on HP defrost

    I have a goodman 2 stage 16 seer HP with a propane GMVM furnace and CTK02 t-stat. What is the reason for a compressor delay during defrost? From my point of view, seems like unneeded compressor...
  19. Replies
    4
    Views
    348

    Can't get past the gate-keeper at Goodman, and I...

    Can't get past the gate-keeper at Goodman, and I was hoping that I didn't need to bug the installer with this kind of question, would rather save him for a real problem. I change the filter without...
  20. Replies
    4
    Views
    348

    I've read that a bunch of times. But this is the...

    I've read that a bunch of times. But this is the first time I have actually comprehended that is says RUN time.. Now I feel stupid. So I suppose that means if I have it set for 1 month, then the...
  21. Replies
    4
    Views
    348

    change filter reminder

    This is too funny.. Goodman GMVM96 with CTK02 t-stat, 2-stage 16 seer HP. I have the change filter reminder set at 1 month and yes, it was turned on. Well, after many months later, the "change...
  22. thanks for the responses..

    thanks for the responses..
  23. many thanks, and one last burning question.

    Hello all.. I have been posting and reading here for many years. The information I gained by all the professionals here has been invaluable. I had a basic propane furnace / old school AC unit when...
  24. new board in HP change the defrost procedure?

    Goodman 16 seer 2 stage HP with modulating furnace and CTK02 t-stat.. from the time it was new, I would get a "No indoor blower" trouble code when coming out of defrost. Finally, Goodman had a fix...
  25. Replies
    2
    Views
    348

    Through the wall unit at a very nice inn

    The Inn at Ohio Northern University, recently completely upgraded including new through the wall HVAC units. When we checked in, the room was cool even though it was set at 75 degrees. Then...
  26. general question for all you professionals..

    Forgive me if this is the wrong place for this post. I was looking at the wall of shame area, came across the HVAC system built by the engineer, and I wonder if any of you add components to your...
  27. Replies
    3
    Views
    487

    Filter is always perfectly clean. But if is was a...

    Filter is always perfectly clean. But if is was a dirty filter and therefore bad indoor airflow, wouldn't that tend to lower the suction and trip out on low pressure?
  28. Replies
    3
    Views
    487

    high pressure trip.

    Goodman 2-stage heat 16 seer heat pump, communicating system. Once in a while, via the t-stat I will check for error codes. Found that over the past 2 months, it has tripped out on high pressure /...
  29. Great news. Thanks for the reply.

    Great news. Thanks for the reply.
  30. That's my question too. Was it just a "shot in...

    That's my question too. Was it just a "shot in the dark to shut the guy up" board or is it a documented problem that now has a verified fix.
  31. I've had the HP for a year, and this is the first...

    I've had the HP for a year, and this is the first time anyone anywhere has ever said anything. Couldn't have a conversation at all, then suddenly Goodman has a new board and tells my tech "problem...
  32. Goodman no indoor blower error code, solved?

    Posted about this before, but no one here was able to offer help, but have helped in so many other ways I thought I would share this:
    3 ton 16 seer 2 stage HP with modulating gas furnace and CTK02...
  33. So is it safe to assume that no one has ever done...

    So is it safe to assume that no one has ever done this? And also no one has ever looked at the network communications as a computer and could benefit from cabling as such?
  34. Any Goodman / Amana guys have thoughts?

    Any Goodman / Amana guys have thoughts?
  35. twisted pair for communication wires, maybe solve occasional communication glitches.

    Goodman communicating system, uses a 4 wire hook up. I saw in the manual that communications can be improved if shielded, twisted pair cable is used for the data lines. So that would mean, as I...
  36. random thoughts after first winter with dual fuel system

    Well, I guess with this winter it might be far from over. Goodman 2 stage 16 seer HP with modulating propane furnace and CTK02 t-stat. Overall, I just love this system. I am amazed how well the HP...
  37. It plugs directly into the board, so not exposed....

    It plugs directly into the board, so not exposed. But probably a bad connection, unless it is a board problem (bad solder joint, hairline crack, etc. I will ask him when it comes out in spring,...
  38. outdoor ambient temp sensor blanking out.

    Goodman 2 stage 3 ton HP, with modulating furnace and CTK02 t-stat. During our first real cold snap about a month ago, below zero outside, come home and the HP is running. I have the dual fuel temp...
  39. Replies
    11
    Views
    990

    I understand.. if it isn't cheaper for you then...

    I understand.. if it isn't cheaper for you then it might as well sit in my garage from your point of view. That makes sense, and I appreciate your honesty. I am in NE Ohio, could this stuff even be...
  40. Replies
    11
    Views
    990

    No clue what it is worth, but I could google it. ...

    No clue what it is worth, but I could google it. Any fair price is better than what I am getting for it sitting in the garage. Can the stuff be shipped without a hassle?
  41. Replies
    11
    Views
    990

    the original nat gas burner and valve for an 80K...

    the original nat gas burner and valve for an 80K Goodman GMVM, never used. The furnace was converted to Propane. And when I bought my house in 1999 it had an R22 AC unit that was not working quite...
  42. Replies
    11
    Views
    990

    can a homeowner sell stuff here?

    Like the subject says..
  43. Replies
    4
    Views
    517

    thank you very much.

    thank you very much.
  44. Replies
    4
    Views
    517

    No picture, and frost was not thick. It was...

    No picture, and frost was not thick. It was probably just starting to restrict airflow, hence the slight drop in temperature rise.
  45. Replies
    4
    Views
    517

    outdoor coil frosting in a pattern.

    Perfect conditions yesterday for frosting of a heatpump. I noticed mine was frosting in a pattern, that eventually filled in almost completely before it went into defrost. When it was completely...
  46. Replies
    8
    Views
    1,040

    Thanks for the replies. But why was this moved...

    Thanks for the replies. But why was this moved to "tech to tech"? I am not a tech!
  47. Replies
    8
    Views
    1,040

    propane vs. natural gas

    See a lot of threads here pertaining to this.. But exactly why is propane harder on equipment than natural gas? Never lived in the city, been on propane my whole life, nearly 50 years.
  48. Replies
    15
    Views
    1,378

    Agreed on the 60k, but too late now! Regarding...

    Agreed on the 60k, but too late now! Regarding the ductwork, in my case I am sure that is okay even for the furnace I have, on high fire with proper temp rise, the static pressure in the ducts are...
  49. Replies
    13
    Views
    1,475

    Oh... well, who knows where the heck that little...

    Oh... well, who knows where the heck that little bracket went! So essentially the little sensing bulb is out in the weather, okay, then where it is now is a reasonable place. My installer told me the...
  50. Replies
    13
    Views
    1,475

    I have painted an incorrect picture for you, I am...

    I have painted an incorrect picture for you, I am sorry about that! This HP has a temp sensor on about a 12" lead that plugs directly into the main board of the HP. It is not connected to the...