    I think they have gotten better recently but I...

    I think they have gotten better recently but I hate their cheap cabinets and from 2005 ish to 2010 they seem to have some serious quality problems
  2. Replies
    81
    Views
    4,013

    I cant believe they give a 5 year warranty on dry...

    I cant believe they give a 5 year warranty on dry shipped units I have seen them installed on 6 seer evaporators my guess is they deny the warranty on the compressor pretty much no matter what

    I...
  3. Replies
    81
    Views
    4,013

    flushing line sets on dry shipped units is not...

    flushing line sets on dry shipped units is not gonna happen and how would you flush the oil out of the evaporator

    I'm not concerned with it
  4. Replies
    13
    Views
    751

    Pulling the disconnect wont de-energize the...

    Pulling the disconnect wont de-energize the reversing valve because it is powered by low voltage from the t-stat

    The unit is low on charge no doubt about it
  5. I think you right don't know exact year though

    I think you right don't know exact year though
  6. Replies
    612
    Views
    105,911

    Got a call today unit wont cool below 74 they...

    Got a call today unit wont cool below 74 they want it 69 inside and wanted me to come out right away I told them to wait or call someone else
  7. Replies
    9
    Views
    381

    its not as humid but systems are definitely...

    its not as humid but systems are definitely working hard to maintain temp
  8. Replies
    9
    Views
    381

    82% with 105 outside That must be miserable I...

    82% with 105 outside That must be miserable

    I don't know what your design is but the load the evaporator is seeing must be huge
  9. Replies
    9
    Views
    381

    whats the relative humidity outside

    whats the relative humidity outside
  10. Replies
    8
    Views
    449

    They usually only have 1 gauge port You can...

    They usually only have 1 gauge port

    You can only charge by weight
  11. Replies
    43
    Views
    1,314

    still hot here but it has not been super hot like...

    still hot here but it has not been super hot like normal aside from a few days
  12. Replies
    8
    Views
    449

    its actually the saturated refrigerant line ...

    its actually the saturated refrigerant line

    did you find the leak?
  13. Replies
    139
    Views
    5,586

    Hummer has been gone since 2010 I would...

    Hummer has been gone since 2010


    I would really like to see dry charged units go because it seems like they are always installed on a 6-8 seer coil
  14. in my experience people don't want to do even the...

    in my experience people don't want to do even the most basic stuff once the condensate line was tied under a sink and the hose connecting it was a little too big and had a slow drip I explained go to...
  15. Replies
    7
    Views
    368

    you can run both into 1 3/4" but if the line...

    you can run both into 1 3/4" but if the line clogs both will be overflowing
  16. scrolls dont pump down that great anyways and...

    scrolls dont pump down that great anyways and there is is a built bypass when the compression ratio exceeds a certain point
  17. We wont be affected because we have never...

    We wont be affected because we have never installed one of those piles
  18. Replies
    952
    Views
    70,875

    so what is included with the I manifold? With...

    so what is included with the I manifold?

    With the wireless temperature humidity probes and wireless base probe it looks like i would be at $1500 don't think it would be worth it.
  19. Replies
    16
    Views
    797

    does not sound bad but maybe try to go back and...

    does not sound bad but maybe try to go back and check under normal conditions
  20. Replies
    9
    Views
    493

    As long as a 2.5 ton is enough capacity with a...

    As long as a 2.5 ton is enough capacity with a txv at the indoor coil it should be fine
  21. Replies
    26
    Views
    1,217

    I paid $10,000 for school and was in no way...

    I paid $10,000 for school and was in no way prepared for much of anything I have learned on the job and this site and some of the guys on youtube have taught me so much

    With most companies looking...
  22. Replies
    9
    Views
    362

    So Friday installed a 5 ton Day & Night heat...

    So Friday installed a 5 ton Day & Night heat pump condenser it had a Copeland scroll and a Genteq Condenser fan motor

    Today installed a Day & night 5 ton straight Cool condenser Zongshan...
  23. Replies
    57
    Views
    7,756

    that cant be real?

    that cant be real?
  24. Replies
    24
    Views
    3,596

    well there has been talk about using hydrocarbon...

    well there has been talk about using hydrocarbon refrigerants as replacement refrigerants this guy is doing the beta testing for everybody :whistle:
  25. Replies
    9
    Views
    362

    I doubt you would see it in the infinity lines...

    I doubt you would see it in the infinity lines most of the Day & nights use Genteq for the condenser fan except in the real small tonnage units. With a 10 year warranty it is not something I am...