Search:

Type: Posts; User: REEFERMAN4U

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    16
    Views
    2,207

    Running on 1 cylinder. Black oil is al/mag powder...

    Running on 1 cylinder. Black oil is al/mag powder from rod. Time for new pump. K bodies are tough puppies. Before installing new k, stand it up on crank end for a minute to fill slinger cup at end of...
  2. Replies
    15
    Views
    1,358

    That box size in FL would normally be 3/4 hp. Go...

    That box size in FL would normally be 3/4 hp. Go with the 1 hp (with accumulator) and defrost clock if none exists. Convert to 404 due to phase out of 22. .03c
  3. Replies
    3
    Views
    614

    2"

    2"
  4. Replies
    11
    Views
    798

    Is there an oil separator? Is the compressor...

    Is there an oil separator? Is the compressor above the evaps?Suction accumulator full of oil, blocked return hole in u bend? INPUT INPUT
  5. Coke is a Joke. (service) They do have really...

    Coke is a Joke. (service) They do have really cool red trucks. ha
  6. Replies
    8
    Views
    684

    Defrost timers can be a bit loud when the plastic...

    Defrost timers can be a bit loud when the plastic gears grind. ??
  7. For locations such as cooks line ,I pull the...

    For locations such as cooks line ,I pull the condensers and remote to cooler location. Then the recovery is much faster and soooooooo much easier to service..03c
  8. Thread: WTF?

    by REEFERMAN4U
    Replies
    59
    Views
    11,108

    We can only hope his ship will return soon and...

    We can only hope his ship will return soon and take his back to Uranus.
  9. I leave my 134a cylinders at the shop for auto...

    I leave my 134a cylinders at the shop for auto only use. Hot shot or 414a is the best drop in for 134a. It floods back nicely and compressors love it . Besides it comes in a pretty blue container.
  10. I did this as well on an old case. Installed an...

    I did this as well on an old case. Installed an oversized liquid drier in the vertical down flow position, this compensates for no receiver tank. .04c
  11. Replies
    5
    Views
    591

    At McDonalds, we overlay 1/4" DP on reversed...

    At McDonalds, we overlay 1/4" DP on reversed seams. Heavy delivery carts from Martin Brower curl up anything thinner..03c
  12. If the problem is wax, the pig will compact the...

    If the problem is wax, the pig will compact the wax into a solid jam. I have only had success with small pieces of debri being pushed. .03c
  13. Replies
    23
    Views
    1,458

    Honesty and reliability. I have had some accounts...

    Honesty and reliability. I have had some accounts for over 20 years and never take them for granted. .03c
  14. Replies
    30
    Views
    2,015

    Lay an 8lb bag of ice on top and it will do a...

    Lay an 8lb bag of ice on top and it will do a fine job. This is the earliest form of refrigeration.
  15. Replies
    19
    Views
    1,328

    Check the condensers outside, most reliable...

    Check the condensers outside, most reliable installers will have ball valves for isolating different coils. .04c
  16. Replies
    11
    Views
    913

    Aussies and Kiwis know their beer stuff!

    Aussies and Kiwis know their beer stuff!
  17. Is this the same freezer you mentioned in 05?...

    Is this the same freezer you mentioned in 05? Your restaurant needs professional help.
  18. Replies
    11
    Views
    1,714

    Replace Compressor

    Replace Compressor
  19. Replies
    8
    Views
    716

    460v ? Should make ice twice as fast.

    460v ? Should make ice twice as fast.
  20. TX problem. Is there a moisture indicator in the...

    TX problem. Is there a moisture indicator in the glass? If ok slightly torch tx bulb and look for change in pressure.
  21. Replies
    4
    Views
    547

    Remove old pan and take to metal shop for...

    Remove old pan and take to metal shop for duplication,much faster on old equip.
  22. 15% on copper 45% on steel and brass

    15% on copper 45% on steel and brass
  23. Thread: Invention!

    by REEFERMAN4U
    Replies
    16
    Views
    1,391

    Some machines need the heat in supply water for...

    Some machines need the heat in supply water for ice release in harvest. .04c
  24. Thread: Hoshizaki

    by REEFERMAN4U
    Replies
    15
    Views
    1,283

    9 out of 10 times / low pressure = freeze up

    9 out of 10 times / low pressure = freeze up
  25. Replies
    6
    Views
    799

    I mainly service McDonalds restaurants in N...

    I mainly service McDonalds restaurants in N Florida. Very Busy all year. "The Happy Meals Must Flow" Haa