Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: A1 Burt

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    16
    Views
    569

    AIR FLOW ?

    AIR FLOW ?
  2. Replies
    15
    Views
    686

    clean the water side of the machine then clean...

    clean the water side of the machine then clean the air side of machine it would be nice if I knew what type machine it is good luck
  3. mike . let one of your h-v-a-c guys build some...

    mike . let one of your h-v-a-c guys build some thing with you when you get back home .good luck.
  4. Thread: Adding R404a

    by A1 Burt
    Replies
    72
    Views
    2,895

    TROLL---TROLL---TROLL

    TROLL---TROLL---TROLL
  5. Thread: Adding R404a

    by A1 Burt
    Replies
    72
    Views
    2,895

    look at the liqed reciver find the sight glasses...

    look at the liqed reciver find the sight glasses should be maybe 4 or 5 bring leavel up to 1st or2nd sight glass then open some walk in cooler & frezer doorsleve them open for a little while maybe...
  6. Replies
    23
    Views
    2,393

    "THIRD WORLD"

    "THIRD WORLD"
  7. Replies
    2
    Views
    260

    since you took X- term off timer just reduce...

    since you took X- term off timer just reduce amount of time on each defrost . get the right fan delay - termator switch hook it up right put defrost time back to were it was . be done with the call .
  8. Replies
    14
    Views
    1,946

    the garden hose must be used for a drain line on...

    the garden hose must be used for a drain line on one of those hook up some where . it was there so lets use that old suction line we can save a lot of money .
  9. i take care of a 1200 modle and thay got it used...

    i take care of a 1200 modle and thay got it used frist thing i had to fix was t-x-v only one was bad but did both any way . about 5 years latter one went bad this time only changed one valve the...
  10. Replies
    52
    Views
    3,348

    this store has one that i think is a 1962 this is...

    this store has one that i think is a 1962 this is ser# w-62A-19067 that one is for a walk in it still has R-12 This other one is for a produce case G-62D-08436 both are 3 phase
  11. mike I had to see where you were from . I have a...

    mike I had to see where you were from . I have a diner with the same ding's I think they used a meat clever It is amazing the thing still drop's ice
  12. Thread: TXV adjustment

    by A1 Burt
    Replies
    17
    Views
    964

    temp control ? L.P.C. ? check them out

    temp control ? L.P.C. ? check them out
  13. superheat=temperture on suction line next to...

    superheat=temperture on suction line next to sencing bulb- then get a presure reading next to sencing bulb convert to temp from a pressure - temperature chart subtrack the two numbers then you will...
  14. Replies
    5
    Views
    446

    1938 frigidaire

    compressor had a lose wire on middle post tighten it up all good . happy camper
  15. Replies
    48
    Views
    4,350

    on simi hermetic where wire hook up to termanile...

    on simi hermetic where wire hook up to termanile post if you see oiley resadew in side when you take cover off there you go be careful when tightening up post!!!
  16. G-E used the stuff as a refrigerant for 18 months...

    G-E used the stuff as a refrigerant for 18 months then stoped methylformate was used in nerve gas .
  17. the C-A modle had METHYL FORMATE in them...

    the C-A modle had METHYL FORMATE in them bad stuff stay away !!!!!!!!!!!!
  18. Thread: Short Cycle

    by A1 Burt
    Replies
    21
    Views
    1,434

    power head on t-x-v ?

    power head on t-x-v ?
  19. Replies
    8
    Views
    1,854

    bradleyshermetics.com I got 3 of them & sight...

    bradleyshermetics.com I got 3 of them & sight glass & o rings & gaskets
  20. Thread: made in china

    by A1 Burt
    Replies
    4
    Views
    630

    bunny that is about right

    bunny that is about right
  21. Thread: made in china

    by A1 Burt
    Replies
    4
    Views
    630

    made in china

    are some manitowoc ice machines made in china ?
  22. Replies
    40
    Views
    3,932

    check hot gas valve for leek

    check hot gas valve for leek
  23. Replies
    7
    Views
    887

    BACK SEAT ?

    BACK SEAT ?
  24. Replies
    22
    Views
    2,641

    Refrigeration hardware supply corporation #...

    Refrigeration hardware supply corporation # 800-716-6655
  25. Replies
    20
    Views
    983

    look around the where evaportor is & look for...

    look around the where evaportor is & look for lowest place is 7 THERE MIGHT be a acces fitting there then you are in luck or call thermol king & ask them the way & what to look out for good luck
Results 1 to 25 of 198
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event