  1. Replies
    3
    Views
    302

    new job leak detector

    Has anybody one tryed this out supply house is pushing it big time
    http://www.jbind.com/products/Aurora-Refrigerant-Leak-Detector.aspx
  2. Replies
    17
    Views
    692

    more thin likely the forced compressor was...

    more thin likely the forced compressor was throwing off the controller next time you should check with a meter to see what is locking it ot
  3. Replies
    10
    Views
    403

    not on the rack unless its a new line up but on...

    not on the rack unless its a new line up but on splits and self contains yes I do
  4. Replies
    10
    Views
    403

    Just go to air gas a get a co2 regulator and a...

    Just go to air gas a get a co2 regulator and a flow meter that's where I got mine its a standers item for mig and tig welding and I have been purging with. Co2 and have no issues
  5. Replies
    5
    Views
    414

    what's they scale down there for a journeymen...

    what's they scale down there for a journeymen start up rack mechanic
  6. Replies
    5
    Views
    414

    union ?

    union ?
  7. Replies
    133
    Views
    4,387

    you could just torch the receiver to see if its...

    you could just torch the receiver to see if its full or just pull some gas in to a recovery cylinder and see when the glass flashes
  8. Replies
    3
    Views
    262

    how to properly a just h10 pm

    How do I properly set up my h10 in manual mode I have herd a least 3 different ways of doing so in manual mode dose the sensor adjustment that you need a screw driver to turn in the super rh corner...
  9. Replies
    8
    Views
    552

    we have been looking for orings for a wile the...

    we have been looking for orings for a wile the oring is very thin and square no orings I have tried have worked
  10. Replies
    8
    Views
    552

    target split condenser valve leaks

    has any one seen a huge number of target split condenser valves leaking I have found 21 in 2 months all are the dead winter condenser and all are sporlan oe35s1110 all of them have the large oring...
  11. Replies
    22
    Views
    988

    http://www.emersonclimate.com/europe/ProductDocume...

    http://www.emersonclimate.com/europe/ProductDocuments/AlcoLiterature/EN_PS3__35003.pdf

    I have a couple of older super plus racks running these the use to sell an adjustable one everything is...
  12. Replies
    1
    Views
    224

    you need to change the ip address of your lap go...

    you need to change the ip address of your lap go to network sharing center right click on Ethernet got to property's go down to tcip internet protocol right click go to property's change the ip and...
  13. Replies
    2
    Views
    361

    Those settings are very low

    Those settings are very low
  14. Replies
    6
    Views
    396

    I do it the way JP dose but some customers get...

    I do it the way JP dose but some customers get squimish when you back door in to there network . I also use a program called jump to control my lap top it works really good
  15. Replies
    43
    Views
    1,830

    you don't need to change the oil you need to find...

    you don't need to change the oil you need to find out why the oil is discolored and over heated its not oil like in your car it dose not just go bad a situation has to destroy it . I would definitely...
  16. Replies
    98
    Views
    5,482

    omg 41000 a year to run supermarket is insane I...

    omg 41000 a year to run supermarket is insane I would not touch that with a 10 foot poll
  17. Replies
    6
    Views
    369

    how big is the reclaim sounds like a good sized...

    how big is the reclaim sounds like a good sized one for that much gas we shift the pressure to get more heat from reclaim we need more info like what kina reclaim we are dealing with air water size...
  18. Replies
    4
    Views
    334

    Do they split and pump out or just shut off...

    Do they split and pump out or just shut off discharge
  19. you have to go to hill and buy it . its an oem...

    you have to go to hill and buy it . its an oem part
  20. any one have this Yellow Jacket 40852 Mini Refrigeration System Analyzer

    looks kind of cool now if only digi cool could make one not crazy about the k type probe but it would be nice to keep in the bag
  21. I am starting to see a lot of new stores that out...

    I am starting to see a lot of new stores that out side have transfer switches and portable generator hook ups out side iam sure Johnson controls or train or York have something in there chiller...
  22. just add bypass valves and hookups for temp...

    just add bypass valves and hookups for temp hoses so you could bypass the chiller that is down .
  23. Replies
    2
    Views
    361

    digi cool trouble

    my battery wire pulled out of my board and I was unsuccessful in sodering it back in could not remove old wire so my question is where do I get a new board .
  24. Replies
    19
    Views
    1,126

    the hand held is simple select the step rate and...

    the hand held is simple select the step rate and hold the button down to open and close the valve . if you are dealing with WalMart you can persuade them to make a change if its valid reason.
  25. Replies
    19
    Views
    1,126

    when it reaches set point it will fully close...

    when it reaches set point it will fully close also yes they can fail intermittently it has a throttle range programed in to the controller so some times it may dip below set point. cycling the power...