Search:

Type: Posts; User: boom

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Schematics

    by boom
    Replies
    2
    Views
    379

    Lol thanks

    Lol thanks
  2. Replies
    473
    Views
    39,498

    I'm tempted to purchase the DC, but I would fear...

    I'm tempted to purchase the DC, but I would fear that expensive investment with all the service van thefts in this broke city & I'm confident my company wouldn't replace that.
  3. Thread: Schematics

    by boom
    Replies
    2
    Views
    379

    Schematics

    Sorry I have a brain fart right now.. Schematics are read in the "N.C." state correct?
  4. Replies
    19
    Views
    2,376

    Sounds like he's craving a knuckle sandwich

    Sounds like he's craving a knuckle sandwich
  5. Thread: comp flood back

    by boom
    Replies
    2
    Views
    616

    Got it figured out. Thanks

    Got it figured out. Thanks
  6. Thread: comp flood back

    by boom
    Replies
    2
    Views
    616

    comp flood back

    Da is at 33*, but sh at 0-1*. I already changed the tev. I already stemed the valve all the way in, but the Da is now at 40* and the sh is now at 3.5*. Medium temp by the way. Feedback would be...
  7. Thread: A True Question

    by boom
    Replies
    9
    Views
    894

    somebody must've installed that prior to your...

    somebody must've installed that prior to your visit. don't think it came from the factory
  8. Thread: Boom

    by boom
    Replies
    36
    Views
    2,929

    Holy Sh*t!

    Holy Sh*t!
  9. Replies
    53
    Views
    4,561

    Why not just stick the probe in THE BUTT OF...

    Why not just stick the probe in THE BUTT OF ENDOCUBE's CEO to get a true temperature reading.
  10. Replies
    11
    Views
    822

    Totally agree. It messes up the sight glass to...

    Totally agree.

    It messes up the sight glass to your gauges, especially if you don't clean it immediately after using them on a system with that crap inside.
  11. Replies
    11
    Views
    822

    True. So are you saying that there are charged...

    True.

    So are you saying that there are charged with dye?
  12. Replies
    11
    Views
    822

    Oh, my bad I forgot to mention that I pin pointed...

    Oh, my bad I forgot to mention that I pin pointed the leak where both line sets (cap & suction) enters the case, however the leak isn't repairable due to the sets being internal. I would have to run...
  13. Replies
    11
    Views
    822

    Self contain beverage case

    I welded on piercing valves due to the system never being opened, but it was completly flat on refrigertant. I cut off the liquid line filter drier and "green oil" dripped out. I was wondering if...
  14. Replies
    2
    Views
    623

    What's the proper way to use Rx-11?

    I have a long way to go, but I started in August. I want to know the proper way to use Rx-11 to flush out the system. Thanks in advanced.
  15. The biggest leak of my life was when I pissed in...

    The biggest leak of my life was when I pissed in the floor drain in the motor room last night :)
  16. Replies
    34
    Views
    3,305

    I know for a fact you're not kidding about the AC...

    I know for a fact you're not kidding about the AC guys :)
  17. Replies
    9
    Views
    1,244

    I cut a liquid line filter drier out of a system...

    I cut a liquid line filter drier out of a system with a capillary tube before and found "white powder like substance" inside. I figured it was due to the generic drier on the system, but now I wonder...
  18. Replies
    49
    Views
    3,070

    Check for temperature drops across each...

    Check for temperature drops across each coupling/90* elbows.
  19. Replies
    6
    Views
    2,329

    ^Haha

    ^Haha
  20. Replies
    49
    Views
    2,869

    An H10 is good, but if you have an electronic...

    An H10 is good, but if you have an electronic leak detector, then try replacing the sensor. The sensor tends to get less sensitive if exposed to concentrated refrigerants or just over normal uses.
  21. Replies
    49
    Views
    2,869

    Don't stop looking. You're already half way...

    Don't stop looking. You're already half way there. Start cutting the insulation now.
  22. Thread: TXV vs EXV

    by boom
    Replies
    34
    Views
    5,415

    Ity's saying article not found?

    Ity's saying article not found?
  23. Thread: TXV vs EXV

    by boom
    Replies
    34
    Views
    5,415

    LOL.. Maybe in the past, another technician did...

    LOL.. Maybe in the past, another technician did service, then evacuated the system without valving off the transducer.
  24. Thread: TXV vs EXV

    by boom
    Replies
    34
    Views
    5,415

    The first types of EXV's they came out with were...

    The first types of EXV's they came out with were literally sh*tty, but they are getting a lot better.
  25. Replies
    10
    Views
    689

    What was your sub cooling reading and where did...

    What was your sub cooling reading and where did you take the reading at???
Results 1 to 25 of 115
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event