    put some gas in this thing, liquid charge right ?

    put some gas in this thing, liquid charge right ?
  2. Replies
    0
    Views
    711

    maytag gas dryer

    anyone ever work on gas dryers ? went to a dry cleaning place and they have about 30 gas fired dryers, most of the high limits have fallen off, anyone know what the cutoff temp is typicly for a gas...
  3. sounds like a restriction to me, check your...

    sounds like a restriction to me, check your metering devise, or anything else that can block the flow.
  4. Replies
    9
    Views
    1,038

    depending on your room temp i would lower the...

    depending on your room temp i would lower the head pressure, if your room temp is 72 to 75 i would like it runing at 210 head
  5. Replies
    5
    Views
    1,079

    well i have 4 of these and 3 of them have some...

    well i have 4 of these and 3 of them have some problems, their a pain to trace out specially the condensor wires, found one with 2 blown fuses in the compressor section, replaced them no i have 2 of...
  6. Replies
    5
    Views
    1,079

    anyone ?

    anyone ?
  7. Replies
    5
    Views
    1,079

    old york rtu

    hi all again for the life of me i dont know how u guys find the manuals and wiring diagrams online but i can not find anything, need help again with a york unit, M# d1ss240g26558epb s#newm258729,...
  8. Replies
    4
    Views
    2,235

    thanks guys yes i wrote down wrong m # thanks...

    thanks guys yes i wrote down wrong m # thanks mark for the info, now happy reading for me lol
  9. Replies
    4
    Views
    2,235

    trane condensing unit

    hi all looking for a wiring diagram for a trane condesing unit, just trying to understand how this beast operates and sequence of operation, specially the call for cooling and bringing on condensor...
  10. Replies
    10
    Views
    2,621

    yes thats why not looking forward to it, and i...

    yes thats why not looking forward to it, and i have 2 condensing units on this unit so pain in the ass X2 lol
  11. Replies
    10
    Views
    2,621

    well finally tech support got back to me, after...

    well finally tech support got back to me, after arguing with me that the unit was originaly 404a i sent them a picture of the nameplate with all the details including it is a 134a unit. now...
  12. Replies
    10
    Views
    2,621

    converting from 134a to 404a

    need some advise on a cold tech freezer, runing 134a right now,someone has put in 2 new compressors that were not the right ones, now coldtech wants to send me 2 new 404a compressors, its a cap tube...
  13. clean your condensor and call a mechanic.

    clean your condensor and call a mechanic.
  14. Replies
    34
    Views
    3,659

    if your experience is only in residential then i...

    if your experience is only in residential then i would move up to commercial work, something a little more challenging but not to crazy on hours like supermarket work. Also keep in mind that some...
  15. Replies
    8
    Views
    776

    check your expansion tank

    check your expansion tank
  16. Replies
    0
    Views
    503

    coldtech freezer

    came across a coldtech freezer m #j4sff40b. found it odd that their using 2 condensing units and evaps on this small reach in with 134a refrigrante, i just found it weird how it even comes down to -4...
  17. Replies
    0
    Views
    1,275

    hydrobank heat pump

    hey all did a search on the net for hydrobank heat pump i guess its made by mammoth, am looking for the wiring diagram for one of these things, model #d030hhj S# 012282884 its a 208 v water source...
  18. Replies
    10
    Views
    1,009

    leaving supermarket refer

    well i've been doing supermaket refrigeration for just over a year, and loved it from 8 to 4 lol but to tell you guys the truth its a brutal trade after hours, barely ever home, calls come in anytime...
  19. company i work for we ave a tower which has a lot...

    company i work for we ave a tower which has a lot of small freezer /cooler units with cap tubes, we have a guy that looks after it and hes replaced quite a few cap tubes to tx valves, i've never done...
  20. Replies
    11
    Views
    1,324

    i would start at the blower, make sure the motor/...

    i would start at the blower, make sure the motor/ cap is all ok, then i would look at the blower delay im assumig its a double stack, christmas tree timer, then inspect the wiring, another way is...
  21. Replies
    12
    Views
    1,280

    yes just repaired one the other day, leaks right...

    yes just repaired one the other day, leaks right at the nut where its supported by, also famous for leaks on the copper tubing under the unit where the evap drain water drains
  22. Replies
    11
    Views
    1,256

    i've beenhaving problems with a receiver logging...

    i've beenhaving problems with a receiver logging gas in this type of system, but my system has a sporlan 3way valve, with a tx valve, bulb attached to the liquid line, i'm guessing it sensing the...
  23. Replies
    14
    Views
    1,284

    this is just a single system.

    this is just a single system.
  24. Replies
    55
    Views
    4,493

    run

    run
  25. Replies
    14
    Views
    1,284

    comp does pumpdown, but it bleeds back a bit from...

    comp does pumpdown, but it bleeds back a bit from the discharge, not runing hot, but also not cool on the belly i guess because of the high superheat, sunction line warm coming back. has a brandnew...
  26. Replies
    14
    Views
    1,284

    thanks guys for all the responses, im not sure if...

    thanks guys for all the responses, im not sure if it ever worked properly, because i cant get a straight answer from these guys, its in a big supermarket chain, inlet screen clean, i put in new bulb...
  27. Replies
    14
    Views
    1,284

    Walkin cooler question

    hey everyone i have a walkin cooler giving me problems, its got a ref plus evap coil with a ton and half tx valve its a brand new coil another company installed in march, anyways i cant get it down...
  28. Replies
    36
    Views
    3,306

    being a supermarket mechanic

    well just a review of my first 4 months being a supermarket mechanic, for all of you looking for hours lol its the side of the trade to be in, so far i've had lots of hours, lots of learning and...
  29. Replies
    2
    Views
    524

    banking hours or not to

    hey everyone just wondering about some benefits or non benefits about banking hours at work, what do most of you guys do ? bank them or take it all home. just started working for a company that is...
  30. Replies
    14
    Views
    1,499

    thanks for the info, actually got an email from...

    thanks for the info, actually got an email from the olsen rep in canada, its a 120000 input 96000 output, made in 81 lol,
  31. Replies
    14
    Views
    1,499

    its a 2 burner furnace

    its a 2 burner furnace
  32. Replies
    14
    Views
    1,499

    olsen furnace info

    ran into an old olsen with a cracked heat exchanger today but no name plate just m and s # written on it, its natural gas, 6 inch vent, horizontal furnace, i'm assuming its 20 years old at least, now...
  33. Replies
    46
    Views
    8,727

    here in toronto i would not recomend you work for...

    here in toronto i would not recomend you work for jci, they are losing customers like crazy, they have laid off over 10 mechanics in the last 2 years, and very unorganized and simply put the office...
  34. my advise to you is start anywhere u can, union...

    my advise to you is start anywhere u can, union shops are not hiring much these days without experience, and there lots of non union hiring, get experience in a non union shop, and work your way into...
  35. Replies
    6
    Views
    1,294

    york rooftop

    Just need some input on a york rooftop unit i came across last week, i did some repairs on the burners and when i got it to fire the indoor fan does not come on, so it trips on the high limit, long...
  36. Replies
    7
    Views
    1,171

    no thats what i meant

    no thats what i meant
  37. Replies
    7
    Views
    1,171

    sorry guys it stands for certificate of...

    sorry guys it stands for certificate of qualifications, aka your mechanics license.
  38. Replies
    7
    Views
    1,171

    when u got your cfq

    Hey guys just wondering when you first got your cfq, how your work/life changed as far as your day to day duties, and how you guys dealt with it.
  39. Thread: metasys

    by redwhitekat
    Replies
    5
    Views
    763

    thanks for the replys, i think the only 2 numbers...

    thanks for the replys, i think the only 2 numbers i can change on this set up is the return high limit and low limit temp, if i remember correctly they range from 20 to 28 "f, i guess i'm just gonna...
  40. Thread: metasys

    by redwhitekat
    Replies
    5
    Views
    763

    metasys

    Just a quick question, i have a few buildings i just took over the their on metasys bas, and i noticed their controling the space temp by i beleive return air high limit reset and return air low...
  41. Replies
    0
    Views
    337

    Looking for work in the GTA toronto

    I'm a Mechanic looking for work in the gta toronto area, served my appreticeship with union companys, but recently got laid off, i have about 1 year experience as a mechanic, with a g1, if anyone...
  42. Replies
    208
    Views
    30,734

    I've been with jci for 1.5 years anow, and ever...

    I've been with jci for 1.5 years anow, and ever since the merger took place with york i hear nothing but negative coments, I personally think everything is going great, there is lots of work, every...
  43. Replies
    10
    Views
    3,428

    I'm sick of these stupid comments by some idiots...

    I'm sick of these stupid comments by some idiots above, if you can't help the **** off.
  44. Replies
    10
    Views
    3,428

    Quick question on this, i live in toronto, whats...

    Quick question on this, i live in toronto, whats the rule of thumb to sizing ac units per sq footage of a house. 1000 sq per ton? also
    I was told most new houses in and around toronto are r2000...
  45. Replies
    20
    Views
    2,257

    Yes i would flush system a couple of times, and...

    Yes i would flush system a couple of times, and see what happens after.