    Yes it was very sooty and had to be cleaned....

    Yes it was very sooty and had to be cleaned. Thanks everyone for your help!
  2. Replies
    9
    Views
    3,700

    The unit was overfiring. The manifold pressure...

    The unit was overfiring. The manifold pressure was at 4.0", and btu/hour was 96k (by meter check). Nameplate is 3.5" and 80k btu/hour. I eliminated the rollout problem by reducing the pressure to...
  3. Replies
    9
    Views
    3,700

    Thank you. I'll check. But wouldn't overfiring...

    Thank you. I'll check. But wouldn't overfiring affect all the chambers?
  4. Replies
    9
    Views
    3,700

    I have An ArcoAire (Snyder General) HVAC: Model...

    I have An ArcoAire (Snyder General) HVAC:
    Model #:GUA080A016-IN
    Serial #0000246426-P05-0106

    I have a flame rollout in the #2 combustion chamber that begins at 2-3 minutes after the main blower...