Search:

Type: Posts; User: amigo

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Thread: BAS Training

    by amigo
    Replies
    7
    Views
    369

    +1 JCI is king.

    +1
    JCI is king.
  2. Replies
    31
    Views
    6,229

    it has been years since I programmed upcms, but...

    it has been years since I programmed upcms, but IIRC certain points in upcm have a comm loss value when it is not seeing the BCU, so to me looks like this is what is happening.
    I suggest you get a...
  3. Replies
    4
    Views
    167

    I don't know what your benchmark is for...

    I don't know what your benchmark is for competitive price, but may be look at:
    http://www.ywiretech.com/system-overview/

    Or send me an email with the other guy's product info and I may be able to...
  4. Replies
    16
    Views
    1,304

    I don't know your system, but seems to me you are...

    I don't know your system, but seems to me you are complicating things too much.
    if you know which zones need to be prioritized, then simply put a normally closed relay(could be time delay on make or...
  5. Replies
    10
    Views
    356

    Okay, thank you, sorry I am a bit confused. So...

    Okay, thank you, sorry I am a bit confused.
    So for PTECs and TECs, I need WCIS to configure their addresses, bacnet info, etc. Can I also view and modify the program of them with WCIS?
    If I can do...
  6. Replies
    10
    Views
    356

    This is great info, thank you. I am starting to...

    This is great info, thank you. I am starting to understand the basics of how Siemens brings it all together.

    Other than Comm Tools, Is the only way to talk to and program PXC through an Insight or...
  7. Replies
    10
    Views
    356

    Thank you, I am in South America/US based. I...

    Thank you, I am in South America/US based. I appreciate the overview.
    Is there a quick way to tell if I have CC or Insight?
    Where are the programs for PXC and PTEC, reside? Can it be sucked out of...
  8. Replies
    10
    Views
    356

    Siemens Desigo BACnet

    I may be getting involved with a Desigo BACnet system, can someone please describe all the tools required, from the front end graphics creation and modifications to programming the PXC and PTEC...
  9. Replies
    8
    Views
    193

    if your Lon device follows the lonmark profile,...

    if your Lon device follows the lonmark profile, that is what it will do for mandatory datapoints such as effective setpoint, etc., the manufacturer can choose to add their own custom points which do...
  10. Replies
    8
    Views
    193

    read page 7 of this:...

    read page 7 of this:
    http://www.lonmark.org/technical_resources/guidelines/docs/profiles/8090_10.pdf
  11. Replies
    3
    Views
    289

    which company bought them out?

    which company bought them out?
  12. Replies
    3
    Views
    368

    you have to buy it from delta, and have to have...

    you have to buy it from delta, and have to have the licensed usb key for it.
    good luck.
  13. Thread: Alerton AZW-5000

    by amigo
    Replies
    4
    Views
    406

    never tried it like that, but that is suppose to...

    never tried it like that, but that is suppose to be one of the main applications for it.
    Don't forget that you will a minimum of 2 AZWs, one will be the co-ordinator, sits on mstp bus connected with...
  14. Replies
    3
    Views
    237

    best bet is to get alerton's software, envision,...

    best bet is to get alerton's software, envision, it is a licensed software.
  15. Replies
    6
    Views
    350

    as the guys mentioned, there is nothing onboard...

    as the guys mentioned, there is nothing onboard any branded jace that let's you program the controllers. You need envison for bactalk which is alerton's pc program and visio on the pc to program the...
  16. Replies
    3
    Views
    249

    Thank you. I was told that it also depends on...

    Thank you. I was told that it also depends on version of DHMI, like if it was version 3.40, then I would need orcaview 3.40. Is possible for you to send me 3.40 iso image or a download link?
  17. Replies
    13
    Views
    683

    Thanks for the details. I think I have now a...

    Thanks for the details.
    I think I have now a clearer understanding of what is gotta happen.
    cheers.
  18. Replies
    3
    Views
    249

    Delta Controls DHMI-7E

    What is needed to program this touch screen? Can I do it with Orcaview 3.33 and DEW key?
  19. Replies
    13
    Views
    683

    I am in the process of suggesting an upgrade for...

    I am in the process of suggesting an upgrade for such an exact system (e-bus and c-bus combo), and was gonna do away with zone managers and just bring in the xl-10 devices, get rid of the c-bus...
  20. Replies
    2
    Views
    264

    Thank you, I get what you are saying but I was...

    Thank you, I get what you are saying but I was really hoping not to have to recreate points.
    But seems like there is no easy way out.
  21. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    547

    did not know z-wave has two frequencies, good to...

    did not know z-wave has two frequencies, good to know, thanks.

    From what I hear RCS themostat is one of the better ones, may be you can ask them if they make an EU version.
  22. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    547

    I suggest you ask Fibaro what they suggest to be...

    I suggest you ask Fibaro what they suggest to be a solid thermostat for their system.
    I am not familiar with Z-Wave much, but google brings up this thread:...
  23. Replies
    2
    Views
    264

    Delta Illustrator question

    First time messing with Delta graphics, Oracview 3.33
    I am trying to bring some third party bacnet points into the graphics, but can't figure how to easily make active/inactive into on/off. I have a...
  24. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    547

    You have misunderstood what that particular...

    You have misunderstood what that particular router you bought does. It does not convert BACnet to IP, it converts BACnet serial to BACnet/IP, but it still will only understand BACnet. Since Fibaro...
  25. Thread: Neptronic Bacnet

    by amigo
    Replies
    9
    Views
    547

    Can Fibaro talk BACnet?

    Can Fibaro talk BACnet?
  26. Replies
    12
    Views
    818

    like Scroo said, as far as I know Trane BCU could...

    like Scroo said, as far as I know Trane BCU could never talk BACnet MSTP. Double check that it is a Trane BCU or something else.
  27. Replies
    13
    Views
    444

    I see that /prism/resources is ENT related. And...

    I see that /prism/resources is ENT related. And how do I reset the counters?
    I think my issue is down stream of UNC, is there a similar command for UNC resources?
    Just be clear, I am in browser...
  28. Replies
    13
    Views
    444

    Site is very remote and presently I only have...

    Site is very remote and presently I only have browser access. Also, can not get into ENT remotely and can not access Admin tool because PC is locked down from remote access.
    I will try...
  29. Replies
    13
    Views
    444

    thx. I can do a system/eventLog via browser...

    thx.
    I can do a system/eventLog via browser session, and not much in there as far as errors, just says that jace rebooted (when I did it on site) and has battery test fail message, some other minor...
  30. Replies
    13
    Views
    444

    how do I get the error log via browser session?

    how do I get the error log via browser session?
  31. Replies
    13
    Views
    444

    one 1000, and about 29 mstp devices on its trunk....

    one 1000, and about 29 mstp devices on its trunk.
    I thought it may be an mstp issue, but I can't explain why a reboot of unc fixes it temporarily. So I tend to rule out an mstp issue.
    The system...
  32. Replies
    13
    Views
    444

    No, have not. What my issue is it seems after a...

    No, have not.
    What my issue is it seems after a couple days from a reboot, UNC seems to stop talking bacnet/ip to mnb-1000 and all the controllers that sit on the mnb-1000s mstp bus.
    Reboot seems...
  33. Replies
    13
    Views
    444

    I am pretty well at last resort, :) hoping there...

    I am pretty well at last resort, :)
    hoping there are such commands for R2 but not sure myself.
  34. Replies
    13
    Views
    444

    TAC UNC-520 reset through browser session

    Is there anyway to reset/restart a UNC-520 through the browser session?
    The UNC (R2 Jace) is hanging up quite often now, and as temporary band-aid I like to be able to remotely reset it/restart the...
  35. red lion is normally very good at tech support,...

    red lion is normally very good at tech support, so I suggest you get in touch with them direct.
    although I have never brought a red lion into mstp, I have messed around with crimson software to know...
  36. I have done your exact setup many times, so I can...

    I have done your exact setup many times, so I can certainly tell you that it works.
    go to envision system properties and make sure all is setup correctly there, bacnet/ip vs bacent/eth, etc.
  37. I assume this is not an Alerton router, if it is...

    I assume this is not an Alerton router, if it is then kontrol is right.
    If it is not then you configure your router how you have to.
    Either case, programming controllers through a router with...
  38. Replies
    4
    Views
    416

    thx, will report back if I end up using it.

    thx,
    will report back if I end up using it.
  39. Replies
    4
    Views
    416

    Thx I guess not many people have used it, I'll...

    Thx
    I guess not many people have used it, I'll see if I am brave enough to be at the bleeding edge.
  40. Replies
    4
    Views
    416

    BABEL BUSTER IP/XL

    Anyone use one of these?
    http://www.csimn.com/CSI_pages/BBIPXL.html

    does it support NCI variables?

    Thanks.
  41. Thank you

    Thank you
  42. you have a product? more info please.

    you have a product? more info please.
  43. Replies
    10
    Views
    732

    cool thanks.

    cool thanks.
  44. Replies
    10
    Views
    732

    @Kontrolthis, what device are you using for...

    @Kontrolthis, what device are you using for mobile access point at the site location?
  45. Thread: trane bmtx, BRD#

    by amigo
    Replies
    0
    Views
    168

    trane bmtx, BRD#

    what is the BRD# for a Trane BMTX?
    also, does anyone have any functional used ones?
    thx
  46. Replies
    7
    Views
    488

    probably just phone bapi (www.bapihvac.com) and...

    probably just phone bapi (www.bapihvac.com) and ask to buy the delta style enclosure. That is if you want to buy in low quantities.
    I am not sure of the origins of the enclosure.
  47. personally I would never deviate from h/w...

    personally I would never deviate from h/w control.
    :.02:
  48. Thread: PEM 1 Controller

    by amigo
    Replies
    10
    Views
    766

    Reaper can you hook me up please?

    Reaper can you hook me up please?
  49. Thread: Jace Alternative

    by amigo
    Replies
    8
    Views
    640

    have no experience with easyio but I agree, looks...

    have no experience with easyio but I agree, looks pretty nice and should do the trick.
  50. Thread: Jace Alternative

    by amigo
    Replies
    8
    Views
    640

    what exactly does your customer want, just a...

    what exactly does your customer want, just a table of values, or does he/she want to adjust as well, trends, alarms etc.?
    I would some type of bacnet/ip software with a cheap router, like:...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event