  1. Replies
    34
    Views
    1,541

    Reachin but only condensers are mine. One low...

    Reachin but only condensers are mine. One low temp one med temp, med temp still on roof not installed
  2. Replies
    34
    Views
    1,541

    Customer refusing to pay

    Can I legally take my equipment back if customer doesn't pay up?

    Installed freezers for customer he gave me a deposit and when job is complete he did not want to pay the rest said that it was too...
  3. Replies
    19
    Views
    955

    Kobe steak every night!!!!!

    Kobe steak every night!!!!!
  4. I would tell him if anyone but me touches it....

    I would tell him if anyone but me touches it. Warranty is void. No questions asked
  5. Replies
    29
    Views
    3,352

    What is that!!!!!!!!

    What is that!!!!!!!!
  6. Replies
    22
    Views
    1,574

    I love when guys do a crappy job. I just have to...

    I love when guys do a crappy job. I just have to show up once after them and his customer becomes mine. Almost always happens.
  7. Replies
    22
    Views
    1,574

    I would be ashamed to leave it like that. I hate...

    I would be ashamed to leave it like that. I hate lazy guys
  8. Replies
    40
    Views
    21,591

    Obviously, if a txt is flooding after being...

    Obviously, if a txt is flooding after being replaced it has to be adjusted. Don't get me wrong when I say I don't adjust. I work on non critical Med temp cases mostly. Most of the time there was no...
  9. Replies
    40
    Views
    21,591

    Thanks for the link

    Thanks for the link
  10. Replies
    40
    Views
    21,591

    Sorry, I've yet to run into a bad accumulator. I...

    Sorry, I've yet to run into a bad accumulator. I see separators go out often. Usually mesh screen has a hole or float is stuck
  11. Replies
    40
    Views
    21,591

    I've never seen an oil return line on...

    I've never seen an oil return line on Accumulators, do you know what size and brand have them?
  12. Replies
    6
    Views
    643

    True, didn't think about that. It's also less...

    True, didn't think about that. It's also less piping with loop if I'm not mistaken
  13. Replies
    40
    Views
    21,591

    Superheat on med temp about 10-14 depending if...

    Superheat on med temp about 10-14 depending if it's open or closed case. Low temp 7-11 depending on same thing
  14. Replies
    40
    Views
    21,591

    Never needed to. Works like a charm every time on...

    Never needed to. Works like a charm every time on sporlan valves. Unless it's a Danfoss valve lol
  15. Replies
    40
    Views
    21,591

    On a new install yes, maybe. But if it was...

    On a new install yes, maybe. But if it was already adjusted and has been running then there should be no reason to adjust. Again, most that needed adjustment were bad. I'm sure if you give customer...
  16. Replies
    40
    Views
    21,591

    I find that if you need to adjust superheat it's...

    I find that if you need to adjust superheat it's better to replace. I work in supermarkets and a store can have up to 100 txvs for different applications. Adjusting usual doesn't work
  17. Replies
    6
    Views
    643

    Best place to place a LLSV

    I do Commercial refrigeration in So Cal, some of my stores have solenoid valves at rack and some at cases. Obviously at rack would be the smarter way to do it because you eliminate the need to look...
  18. Thanks everyone for the feedback. Ive removed...

    Thanks everyone for the feedback. Ive removed Solenoid and wired to shut condensing unit off. i was able to add more charge without changing head pressure too much. Hope it works.
  19. Replies
    12
    Views
    954

    If everyone did a good job, there wouldn't be...

    If everyone did a good job, there wouldn't be much work for us good guys
  20. If i decide to go the receiver route i will...

    If i decide to go the receiver route i will probably just double my capacity 24lbs vs 11.7 and take out old receiver and put new one on outside. 2 will look stupid to me. seems like I'm asking to be...
  21. Ive ran a smaller unit for 2 cases same length...

    Ive ran a smaller unit for 2 cases same length and didn't have any issues. You've seen this before?
  22. Outdoor unit.

    Outdoor unit.
  23. Id like to see a pic for future reference. ...

    Id like to see a pic for future reference. Wouldn't even know how to size or pipe the thing.
  24. Exactly why i don't want to go the route

    Exactly why i don't want to go the route
  25. LMAO hahah Sorry guys been swapped with calls...

    LMAO hahah

    Sorry guys been swapped with calls left and right. Im going back Thursday to remove LLSV and add a little bit of Freon.

    To answer some questions

    System is brand new. Evacuated 3...
  26. So its okay to have receiver outside condensing...

    So its okay to have receiver outside condensing unit?
  27. Sorry 11.3 its TEHA020E6

    Sorry 11.3 its TEHA020E6
  28. 11.7 @90%

    11.7 @90%
  29. Right before T on first case

    Right before T on first case
  30. Problem is, Trenton builds their units pretty...

    Problem is, Trenton builds their units pretty tight. Dont have room inside unit. Only option would be outside unit which i dont like
  31. High-side 248 psi Low-side 60.2 psi 75 degree...

    High-side 248 psi Low-side 60.2 psi
    75 degree ambient
    during pump down climbs to 340 right before it shuts off on LP

    Evacuvated system 3 times. got down to about 800 microns (I know 200-500 is...
  32. Bought condensing unit ready to go. Weighed in...

    Bought condensing unit ready to go. Weighed in initial charge 12lbs. System starving, continued added and pumping down every couple pounds to insure HP switch doesnt go off during pump down
  33. @90% 11.7lbs. I have a 60ft line set run, 1/2...

    @90% 11.7lbs. I have a 60ft line set run, 1/2 Liquid 7/8 Suction. reduced at cases to 3/8 liquid. Pump down is another issue. If i ever needed to pump down i would be screwed. I would most likely...
  34. One inside case before lines going to evap....

    One inside case before lines going to evap. Customer doesnt want to spend more money. One of those just bandaid it customers
  35. Undersized Liquid Reciver..........Help!!!!!

    I have a Trenton TEHA020 Condensing unit that feeds to 3 Kysor Warren cases (2 five doors, 1 three door). According to my calculation condensing unit is not undersized. about 21% over whats needed in...
  36. Wow that's one old video. Very informative...

    Wow that's one old video. Very informative nonetheless. I've always set it up with LLSV but have a couple guys arguing about best way.

    I also, run into a lot of bad LP switchs so had me thinking
  37. Thanks for the replies. So I shouldn't worry...

    Thanks for the replies. So I shouldn't worry about LP failing?
  38. Proper way to wire single circuit condensing unit.

    Ive been having a lot of he said this and he said that talks with other techs. Thought id ask here.

    What is the proper way to setup a condensing unit that controls one circuit?

    Setup 1- Wire...
  39. I would ask for at least an amount to cover...

    I would ask for at least an amount to cover parts. because half might not cover parts.
  40. Replies
    12
    Views
    851

    Had same issue. Installed check valve at...

    Had same issue. Installed check valve at discharge. Problem solved
  41. :eek::eek: lol "Never Let The Weak Dilute...

    :eek::eek:
    lol

    "Never Let The Weak Dilute Your Mind"-Anonymous
  42. I would understand a weeknd call and that much...

    I would understand a weeknd call and that much driving.

    I just watched 20/20 a couple weeks ago and they made seem as if $130 for something small was a rip off (loose fuse). I don't want to be...
  43. Service calls; When and when not to charge??

    Recently, I went out on a call to cover a friend for a freezer at a super market and was there about 5-10min before realizing it was a loose wire. It solved the problem.

    My question, do I...
  44. Replies
    71
    Views
    3,611

    Dude, Stop being a d*ck head "Never Let The...

    Dude, Stop being a d*ck head

    "Never Let The Weak Dilute Your Mind"-Anonymous
  45. Replies
    71
    Views
    3,611

    tech and doctor, impressive "Never Let The...

    tech and doctor, impressive

    "Never Let The Weak Dilute Your Mind"-Anonymous
  46. Replies
    71
    Views
    3,611

    Looking back at what I wrote, I now understand. ...

    Looking back at what I wrote, I now understand. I should have just asked the question with amount of years in.

    I got defensive because I've been reading threads on this site for about 2 years...
  47. Replies
    71
    Views
    3,611

    So what if I had put 5 1/2 years experience. ...

    So what if I had put 5 1/2 years experience. Would I come off as cocky or realistic?

    "Never Let The Weak Dilute Your Mind"-Anonymous
  48. Replies
    71
    Views
    3,611

    What area are you referring to? "Never Let The...

    What area are you referring to?

    "Never Let The Weak Dilute Your Mind"-Anonymous
  49. Replies
    71
    Views
    3,611

    I'm looking for answers not opinions. For that...

    I'm looking for answers not opinions. For that reason, I got defensive. I appreciate your input. But everything is transitioning to digital. Even the local 7 elevens are going to controllers for...
  50. Replies
    71
    Views
    3,611

    To clear all confusion. I don't work for a...

    To clear all confusion. I don't work for a refrigeration company. I'm in house and one company owns all locations mentioned