  1. Thread: Honeywell XBS

    by Cal1
    Replies
    11
    Views
    297

    Anyone help me figure out how to set the base...

    Anyone help me figure out how to set the base address on a XPC 500 ISA card it has two rotary switches with 0-thru 9 and a the f i believe. I have searched for weeks here trying get some...
  2. Replies
    16
    Views
    1,859

    Hi I know this an old thread but i need a driver...

    Hi
    I know this an old thread but i need a driver for XPC 500 ISA board my local vendor is not much help :( any help would be appreciated.

    Thanx
  3. Replies
    285
    Views
    47,789

    Hi ControlTec, Thank you for the reply I am...

    Hi ControlTec,
    Thank you for the reply I am really looking for a PEM1 programers manual and a GCM programers manual.I appreciate the feedback and yes I am using the infocon driver.I can see all the...
  4. Replies
    285
    Views
    47,789

    System 8000

    Can anyone help me out here?
  5. Replies
    285
    Views
    47,789

    Hi everyone, I too have a Network 8000 system...

    Hi everyone,
    I too have a Network 8000 system and need to make changes as the GCM is being replaced with a Jace.I have discovered the PEM's and the MZ11 checked the logic blocks in the GCM with...
  6. Replies
    15
    Views
    4,214

    RE:VMA

    Sit down with a cup of joe and read up on your states and other things like saturation timers etc and then do as proxyking says disable prac and check your propbands.
    GB
  7. Replies
    8
    Views
    660

    RE:JCI

    Like i said contact me via my Email my office is located in Metro Boston Area.
    GB
  8. Replies
    8
    Views
    660

    JCI

    Very experienced wth PMI NCM GPL JCBASIC contact info in my profile
  9. Thread: Honeywell XBS

    by Cal1
    Replies
    3
    Views
    1,051

    Honeywell XBS

    After a recent power failure we cant log on with any of the user ID's. Is there a default password for XBS 1.4.3? My email addy is in my profile if you can help us that would be great.
  10. Replies
    10
    Views
    1,119

    You could send the N30 out to be repaired or...

    You could send the N30 out to be repaired or install a Tridium style supervisory FX20 would work just fine for you.
  11. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,598

    Re: Trane Intellipak

    Thank You everyone that did the trick although the DWU was set below the Occupied Heating setpoint they may have been set to closely together.
    In addition patience is the key it took a long time for...
  12. Replies
    5
    Views
    765

    RE: FX SERVER

    I appreciate the help and yes I have been to the FX Supervisory Control training class couple years ago but they did not cover the server setup in great detail. I have looked into the AX...
  13. Thread: JCI GPL

    by Cal1
    Replies
    8
    Views
    1,423

    RE:GPL

    Hi,
    What rev PMI and GPL are you running and on what kinda computer is that XP machine there spanky?
    Shutdown PMI and launch GPL from the FMS/BIN directory. I dont think GPL was ever tested on XP...
  14. Thread: NCM Battery

    by Cal1
    Replies
    9
    Views
    1,754

    The last one i ordered from JCI this past Summer...

    The last one i ordered from JCI this past Summer had a lead time of 8 weeks. Try Ebay buy an old NCM 350 and use the power supply.

    GB
  15. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,598

    RE:Intellipak

    I thank you all for your help I will be on site later this week and will try the setpoint and review the sequence of operation.Its getting cold up here in the NE :) good for business.

    GB
  16. Replies
    5
    Views
    765

    FX Server Questions

    I have a question on the alarm portal.My Niagara Network is all setup three FX's all see each other and the server.I setup a station recipient for each FX pointing to the server but my alarms are not...
  17. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,598

    Hi Mark, Yes I tried that yesterday and the gas...

    Hi Mark,
    Yes I tried that yesterday and the gas heat stages on normally in test mode.The only recent issue with the unit has been the static pressure has been reading hi I am waiting on a altivar...
  18. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,598

    Trane Intellipak

    Hi,
    I have a problem with a Trane Intellipak.The unit wont stage the gas burner on the heat mode enables but the heat does not stage on.All the temperature sensors are reading ok.I put the unit in...
  19. Trending

    Setup M-Trend for the points you need to trend when you want to archive your trend data simply look for the Trenddb.mdb file in the Mdata or active database subdirectory and copy a blank Trenddb.mdb...
  20. Replies
    10
    Views
    1,096

    Re:DCM

    Go the Niagara route AX of FX especially if your GPL for the DCM's is complex.The programing capability on the AX/FX is vastly superior to the Extended Architecture product line.
    GB
  21. Replies
    8
    Views
    1,226

    M3 Password

    Wow that Sam I must ask thread has legs anyways onto your question try this...


    To reset and set up M-Password:

    1) Select Start > Programs > JCI > M-Password > Config. Leave User Name blank...
  22. Replies
    15
    Views
    1,292

    RE:Return Fan

    Do you have a occupied BD point? Just curious why you are scheduling the fan command itself and not the occupied command.You could also schedule the shutdown command BD 197 if need be. Any chance...
  23. Replies
    15
    Views
    1,292

    RE:Schedule

    What point are you scheduling?
  24. Replies
    24
    Views
    1,463

    Re: NCM

    I will assume you have a NCM 350.Did you check your Novram in the NCM kinda curious as to what port the modem is assigned to.What type code general with OT or NT use NT when you have a modem assigned...
  25. Thread: N-30 Resets

    by Cal1
    Replies
    7
    Views
    560

    Re:N30

    That sounds like a normal power up sequence for the N30. Leave it alone is my advice we have had several fail downloads and go into boot code conditions or worse for no reason at all. Time to upgrade...
  26. Thread: N-30 Resets

    by Cal1
    Replies
    7
    Views
    560

    Re:N30

    Is the DS2 red led on steady or flashing? Does the controller reset continuously?

    GB
  27. Replies
    15
    Views
    1,482

    RE:Sensor

    If you rule out the sensor and connections it sounds as though the only thing left is the wire. I will assume the sensor has worked correctly in the past.Is the sensor mounted in a short penetration...
  28. Replies
    2
    Views
    377

    Re: Custom Control

    Thank you again Freddie I got it.

    Boolean Writable to the Numeric Switch block null the output and it releases the command back to local control. I showed a buddy of mine who still works for JCI...
  29. Replies
    2
    Views
    377

    FX Custom Control Question

    Hi,
    I have a FX60 that i need to adjust some setpoints based on the AHU occupied command. If the ahu is occupied in need to release the points to auto. If unocc I need to adjust the points. Im...
  30. Thread: String Conversion

    by Cal1
    Replies
    5
    Views
    483

    Re:Why it is a string type

    I will try to change the point type on Monday. Thank you guys.


    GB
  31. Thread: String Conversion

    by Cal1
    Replies
    5
    Views
    483

    Re:Why it is a string type

    Thats how the FX pulled the point in. I may need to change the point type before I pull it into the database maybe?

    GB
  32. Thread: JCI NIE Offline

    by Cal1
    Replies
    7
    Views
    752

    Double Reset

    I had to do that whenever I ran PIMPAK/PIMLOAD. They brought it back just for the MESA.

    Ping your Ethernet to Arcnet Hub IP. The IP is on the PMI workstation under setup I believe. it sounds like...
  33. Thread: String Conversion

    by Cal1
    Replies
    5
    Views
    483

    String Conversion

    Hi all,
    Kinda stuck and its getting late. I need to animate my fan on a BACNET string point its a 0 or a 1. I assume I need to convert with something in conversion section in KitControl. I searched...
  34. Thread: JCI NIE Offline

    by Cal1
    Replies
    7
    Views
    752

    Re:NIE

    If your NCMS are offline on the PMI side of the world then start there. Whats the N1 type Arcnet or Ethernet?
  35. Replies
    22
    Views
    1,889

    Re: COE design group

    I knew they were doing design work on sold jobs over a certain dollar value. They LSS were complaining about the cost for the engineering and the lack of support from them after the job was under way...
  36. Replies
    7
    Views
    745

    Re:Firmware

    Thank You
    Ninax and Tk2K for the fast reply. I will be going back on site this week and will get the firmware version.

    GB
  37. Replies
    7
    Views
    745

    Network 8000 Upgrade

    Hi,
    We have a customer with a Network 8000 GCM rev 5.3A talking to Invensys PEM1 controllers via ASD trunk.They currently use a XPSI with a DOS terminal. My question is are there any Johnson FX or...
  38. Replies
    12
    Views
    3,138

    Re: N30

    Found this in the FSC database hope it helps,

    Trying to perform an N30 upgrade from 1.x to 2.x Project Builder and it doesn't work.

    Cause:
    User was attempting to upload the N30 directly...
  39. Replies
    13
    Views
    1,590

    Re: Valve

    I would go with a .5 to 1 psi drop across the valve for a 1 inch supply. Check your pump head to get the closeoff you need. Use a two position valve they are cheaper to buy and install and try use...
  40. Replies
    7
    Views
    680

    Re: Sensor

    Looks like a suction line freeze limit safety to me.
  41. Noisy Valve

    Sounds like the system is moving to much water thru the valve and exceeding the CV rating for the valves and creating cavitation within the valve seat.This will ruin the valves in a short amount of...
  42. Replies
    18
    Views
    1,089

    I would consider this replace the 5 N-30's with 5...

    I would consider this replace the 5 N-30's with 5 FX-20's add an FX server and your good to go. Why load up an FX-60 ? If it crashes you loose access to your whole site. The N2 trunks can stay put no...
  43. Replies
    4
    Views
    560

    Sounds like its already been integrated once...

    Sounds like its already been integrated once already to the NCM S2 trunk from a JC85/40 showing my age here but the stuff was solid thats 25 years old man!.What other field devices do you have? Any...
  44. Thread: FX20 Factory IP

    by Cal1
    Replies
    17
    Views
    5,347

    FX20

    Thank You Checkvalve and Ninax. Yes it was a typo on the IP address. I also did try to shell into the FX20 set the jumper as indicated under the cover on the left side using the two pins vertically...
  45. Thread: FX20 Factory IP

    by Cal1
    Replies
    17
    Views
    5,347

    FX20 Factory IP

    FYI
    Just had a FX20 fresh out of the box the factory IP was not 192.168.1.49. It was 192.168.1.126. I didn't have the RJ45 to DB9 connector or the Silver Satin patch cable for the system shell...
  46. Thread: NCM Upload

    by Cal1
    Replies
    10
    Views
    1,152

    NCM wont upload

    Have you checked the NCM error log look for 538 and 529 errors.To rule out duplicate IP addresses disconnect the NCM from the network and go to a non Metasys workstation and ping the IP for the NCM...
  47. Replies
    17
    Views
    2,170

    Ncm 200

    Koliub,
    Your not making a mistake the address changed from 20 to 3 cycle power on the NCM the Novram is now configured for Node 3.

    GB
  48. Replies
    30
    Views
    2,637

    DX9100 Comm issue

    If you are scanning the N2 buss with HVACPRO thru the NCM the DX9100 N2 addresses should come up on the list as offline. If the N2 addresses are missing from the list entirely the devices are not...
  49. Replies
    15
    Views
    2,079

    HvacPro

    Point well taken on the tubes however the option for Press Independent w BO for Autocalibration solenoid equalizes the DP sensor essentially doing the same thing as disconnecting them from the duct...
  50. Replies
    11
    Views
    859

    HVAC PRO logic q's

    FYI

    Look in the help section on HVACPRO and look under sideloop applications it explains in great detail how this operates. How long has this been happening at the site?

    GB